TRESCAL, INC. - Richmond, VA

6540 Emmaus Church Road Suite 106, 23140, Providence Forge, VA, United States

Visit website
A2LA 1486.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1486.02 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage – Generate3 (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 0.8 µV + 16 nV/mV 17 µV + 5 µV/V 88 µV + 7 µV/V 0.56 mV + 14 µV/V 2.7 mV + 14 µV/V Fluke 5522A DC Voltage – Measure3 Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 20) kV (20 to 35) kV (35 to 40) kV 0.33 µV + 17 µV/V 0.52 µV + 8 µV/V 8.8 µV + 8.1 µV/V 35 µV + 10 µV/V 0.2 mV + 12 µV/V 2.3 % 1.2 % 2.3 % HP 3458A Fluke 80K-40 probe & HP 3458A DC Current – Generate3 Clamp-On Ammeters Up to 330 µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (3.2 to 200) A (16 to 1000) A 16 nA + 0.12 nA/µA 41 nA + 80 nA/mA 0.21 µA + 80 nA/mA 2.1 µA + 80 nA/mA 33 µA + 0.16 mA/A 0.37 mA + 0.13 mA/A 0.49 mA + 0.39 mA/A 9.4 mA + 0.8 mA/A 7.5 mA + 2.6 mA/A 37 mA + 2.6 mA/A Fluke 5522A 5520A w/: 10-turn coil 50-turn coil DC Current – Measure3 (0 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 41 pA + 89 µA/A 41 pA + 24 pA/µA 40 pA + 24 pA/µA 82 pA + 22 pA/µA 6 nA + 24 nA/mA 53 nA + 21 nA/mA 0.53 µA + 37 nA/mA 10 µA + 0.11 mA/A HP 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 3 of 14 Parameter/Equipment Range CMC2, 4 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF 9 pF + 4 pF/nF 10 pF + 4 pF/nF 13 pF + 4 pF/nF 15 pF + 2 pF/nF 0.1 nF + 2 pF/nF 0.15 nF + 2 pF/nF 0.5 nF + 2 pF/nF 1.5 nF + 2 nF/µF 5 nF + 2 nF/µF 14 nF + 2 nF/µF 60 nF + 3 nF/µF 0.2 µF + 4 nF/µF 0.63 µF + 4 nF/µF 2 µF + 4 µF/mF 7 µF + 4 µF/mF 38 µF + 2.5 µF/mF 90 µF + 6 µF/mF Fluke 5522A DC Resistance – Generate3 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1099.999) Ω (1.1 to 3.299 999) kΩ (33 to 10.999 99) kΩ (1 to 32.999 99) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ (0.33 to 1.099 99) MΩ (1.1 to 3.299 00) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 1.2 mΩ + 24 µΩ/Ω 1.5 mΩ + 24 µΩ/Ω 1.9 mΩ + 22 µΩ/Ω 4.1 mΩ + 22 µΩ/Ω 9.1 mΩ + 22 µΩ/Ω 41 mΩ + 22 µΩ/Ω 92 mΩ + 22 µΩ/Ω 0.41 Ω + 22 µΩ/Ω 0.9 Ω + 22 µΩ/Ω 8.4 Ω + 26 µΩ/Ω 14 Ω + 26 µΩ/Ω 93 Ω + 48 µΩ/Ω 0.4 kΩ + 0.1 mΩ/Ω 4.4 kΩ + 0.2 mΩ/Ω 16 kΩ + 0.4 mΩ/Ω 0.35 MΩ + 2.4 mΩ/Ω 4.4 MΩ + 12 mΩ/Ω Fluke 5522A Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 55 µΩ + 15 µΩ/Ω 0.52 mΩ + 13 µΩ/Ω 0.53 mΩ + 10 µΩ/Ω 5.3 mΩ + 10 µΩ/Ω 53 mΩ + 11 µΩ/Ω 2.3 Ω + 17 µΩ/Ω 0.1 kΩ + 55 µΩ/Ω 1 kΩ + 0.52 mΩ/Ω 10 kΩ + 5.1 mΩ/Ω HP 3458A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 4 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators3 – Pt 385, 100 Ω Field Calibration3 Pt 3926, 100 Ω Field Calibration 3 Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 100) °C (100 to 300) °C (300 to 600) °C (600 to 800) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 100) °C (100 to 300) °C (300 to 630) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (> 0 to 100) °C (> 100 to 260) °C (> 260 to 300) °C (> 300 to 400) °C (> 400 to 600) °C (> 600 to 630) °C (-200 to -80) °C (> -80 to 100) °C (> 100 to 260) °C (> 260 to 400) °C (> 400 to 600) °C (> 600 to 630) °C 0.042 °C 0.041 °C 0.057 °C 0.073 °C 0.081 °C 0.097 °C 0.19 °C 0.19 °C 0.31 °C 0.44 °C 0.57 °C 0.041 °C 0.041 °C 0.057 °C 0.073 °C 0.081 °C 0.097 °C 0.19 °C 0.31 °C 0.44 °C 0.033 °C 0.042 °C 0.049 °C 0.065 °C 0.073 °C 0.19 °C 0.034 °C 0.033 °C 0.042 °C 0.097 °C 0.11 °C 0.11 °C 0.13 °C 0.034 °C 0.042 °C 0.05 °C 0.065 °C 0.073 °C 0.089 °C Fluke 5522A Fluke 726 Fluke 5522A Fluke 726 Fluke 5522A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 5 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators3 – (cont) Pt 385, 1 kΩ PtNi 385, 120 Ω Cu427.10 Ω (-200 to 0) °C (> 0 to 100) °C (> 100 to 260) °C (> 260 to 300) °C (> 300 to 600) °C (> 600 to 630) °C (-80 to 100) °C (> 100 to 260) °C (-100 to 260) °C 0.026 °C 0.033 °C 0.042 °C 0.049 °C 0.057 °C 0.19 °C 0.066 °C 0.11 °C 0.24 °C Fluke 5522A Electrical Calibration of Thermocouple Indicators – Type E Field Calibration 3 Type J Field Calibration 3 Type K Field Calibration 3 Type T Field Calibration 3 (-200 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-250 to -100) °C (-100 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-250 to -100) °C (-100 to 1000) °C (-100 to 1000) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to 0) °C (0 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-250 to 0) °C (0 to 400) °C 0.4 ᵒC 0.13 ᵒC 0.11 ᵒC 0.13 ᵒC 0.17 ᵒC 0.8 °C 0.53 °C 0.22 ᵒC 0.13 ᵒC 0.11 ᵒC 0.14 ᵒC 0.18 ᵒC 0.53 °C 0.27 °C 0.4 °C 0.27 ᵒC 0.14 ᵒC 0.13 ᵒC 0.21 ᵒC 0.32 ᵒC 0.8 °C 0.4 °C 0.67 °C 0.51 ᵒC 0.21 ᵒC 0.15 ᵒC 0.13 C 0.8 °C 0.27 °C Fluke 5522A Fluke 726 Fluke 5522A Fluke 726 Fluke 5522A Fluke 726 Fluke 5522A Fluke 726
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 6 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 10 kHz 5.5 µV + 0.64 µV/mV 5 µV + 0.12 µV/mV 5 µV + 0.16 µV/mV 5.6 µV + 0.8 µV/mV 12 µV + 2.8 µV/mV 47 µV + 6.4 µV/mV 47 µV + 6.4 µV/mV 14 µV + 0.24 µV/mV 24 µV + 87 nV/mV 11 µV + 0.13 µV/mV 35 µV + 0.28 µV/mV 47 µV + 0.64 µV/mV 0.11 mV + 1.6 µV/mV 0.11 mV + 1.6 µV/mV 0.12 mV + 0.24 mV/V 88 µV + 0.12 mV/V 99 µV + 0.15 mV/V 0.12 mV + 0.24 mV/V 0.29 mV + 0.56 mV/V 1.1 mV + 1.9 mV/V 1.1 mV + 1.9 mV/V 1.3 mV + 0.24 mV/V 0.94 mV + 0.12 mV/V 1.6 mV + 0.18 mV/V 1.4 mV + 0.28 mV/V 3.7 mV + 0.72 mV/V 6.8 mV + 0.15 mV/V 10 mV + 0.16 mV/V 12 mV + 0.2 mV/V 13 mV + 0.24 mV/V 93 mV + 1.6 mV/V 88 mV + 0.24 mV/V Fluke 5522A AC Voltage – Measure3 (1 to 10) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 6.1 µV + 0.0003 mV/mV 4.1 µV + 0.0002 mV/mV 4.2 µV + 0.0003 mV/mV 4.9 µV + 0.001 mV/mV 9 µV + 0.005 mV/mV 45 µV + 0.04 mV/mV HP 3458A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 7 of 14 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage – Measure3 (cont) (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 12 µV + 0.000 07 mV/mV 2.7 µV + 0.000 07 mV/mV 11 µV + 0.000 14 mV/mV 12 µV + 0.0003 mV/mV 17 µV + 0.0008 mV/mV 47 µV + 0.003 mV/mV 0.12 mV + 0.01 mV/mV 3.8 mV + 0.02 mV/mV 0.12 mV + 0.000 07 V/V 0.1 mV + 0.000 07 V/V 0.11 mV + 0.000 14 V/V 0.12 mV + 0.0003 V/V 0.17 mV + 0.0008 V/V 0.47 mV + 0.003 V/V 1.2 mV + 0.01 V/V 38 mV + 0.015 V/V 1.2 mV + 0.000 07 V/V 1 mV + 0.000 07 V/V 1 mV + 0.000 14 V/V 1.2 mV + 0.0003 V/V 1.7 mV + 0.0008 V/V 4.7 mV + 0.003 V/V 12 mV + 0.01 V/V 0.38 V + 0.015 V/V 13 mV + 0.0002 V/V 11 mV + 0.0002 V/V 11 mV + 0.0002 V/V 13 mV + 0.0004 V/V 21 mV + 0.001 V/V 57 mV + 0.004 V/V 0.17 V + 0.015 V/V 99 mV + 0.0004 V/V 85 mV + 0.0004 V/V 98 mV + 0.0006 V/V 0.14 V + 0.0012 V/V 0.27 V + 0.003 V/V 5.8 % HP 3458A Fluke 80K-40 probe & HP 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 8 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (29 to 330) µA 330 μA to 3.3 mA (3.3 to 33) mA (33 mA to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.13 µA + 1.6 nA/µA 0.12 µA + 1.2 nA/µA 0.11 µA + 1 nA/µA 0.19 µA + 2.4 nA/µA 0.35 µA + 6.4 nA/µA 0.70 µA + 13 nA/µA 0.65 µA + 1.6 µA/mA 0.45 µA + 1 µA/mA 0.39 µA + 0.8 µA/mA 0.69 µA + 1.6 µA/mA 2.9 µA + 1.6 µA/mA 3.4 µA + 8 µA/mA 6.4 µA + 1.4 µA/mA 4 µA + 0.72 µA/mA 2.7 µA + 0.32 µA/mA 3.7 µA + 0.64 µA/mA 7.7 µA + 1.6 µA/mA 14 µA + 3.2 µA/mA 65 µA + 1.4 µA/mA 42 µA + 0.72 µA/mA 29 µA + 0.31 µA/mA 68 µA + 0.8 µA/mA 0.13 mA + 1.6 µA/mA 0.27 mA + 3.2 µA/mA 0.56 mA + 1.4 mA/A 0.22 mA + 0.4 mA/A 2.4 mA + 4.8 mA/A 11 mA + 20 mA/A 1.7 mA + 1.4 mA/A 0.61 mA + 0.48 mA/A 6.1 mA + 4.8 mA/A 26 mA + 20 mA/A 3.1 mA + 0.48 mA/A 4 mA + 0.8 mA/A 74 mA + 24 mA/A Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 9 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (11 to 20.5) A Clamp-On Ammeters (3.2 to 200) A (16 to 1000) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz 15 mA + 0.96 mA/A 17 mA + 1.2 mA/A 0.27 A + 24 mA/A 7.6 mA + 3.1 mA/A 38 mA + 3.1 mA/A Fluke 5522A 5520A w/: 10-turn coil 50-turn coil AC Current – Measure3 Up to 100 μA 100 μA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz 57 nA + 4 nA/µA 45 nA + 1.5 nA/µA 40 nA + 0.64 nA/µA 0.43 µA + 0.0041 mA/mA 0.31 µA + 0.0016 mA/mA 0.26 µA + 0.000 67 mA/mA 0.25 µA + 0.000 37 mA/mA 0.26 µA + 0.000 67 mA/mA 0.63 µA + 0.0042 mA/mA 1.8 µA + 0.0056 mA/mA 2.4 µA + 0.0041 mA/mA 2.3 µA + 0.0016 mA/mA 2.3 µA + 0.000 67 mA/mA 2.3 µA + 0.000 37 mA/mA 2.3 µA + 0.000 67 mA/mA 4.5 µA + 0.0041 mA/mA 16 µA + 0.0056 mA/mA 2.4 µA + 0.0041 mA/mA 2.3 µA + 0.0016 mA/mA 2.3 µA + 0.000 67 mA/mA 2.3 µA + 0.000 37 mA/mA 2.3 µA + 0.000 67 mA/mA 4.5 µA + 0.0041 mA/mA 16 µA + 0.0056 mA/mA 0.42 mA + 0.0041 A/A 0.3 mA + 0.0017 A/A 0.26 mA + 0.0009 A/A 0.27 mA + 0.0011 A/A 0.37 mA + 0.0031 A/A 0.92 mA + 0.01 A/A HP 3458A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 10 of 14 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Oscilloscopes3 – DC 50 Ω 1 MΩ Square Wave 50 Ω 1 MΩ Edge Into 50 Ω Leveled Sine Wave Time Marker Wave Generator ± (0 to 6.6) V ± (0 to 130) V 1 mV to 6 V p-p 1 mV to 130 Vp-p 10 Hz to 1 kHz (1 to 100) kHz (200 to 300) ps (100 kHz to 2 MHz) (200 to 350) ps (2 to 10) MHz 5 mV to 5.5 V 50 kHz (reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 4 mV to 3.5 V (600 to 1100) MHz 5 s to 50 ms 50 ms to 1 ns 1.8 mV to 2.8 V p-p (50 Ω) 10 Hz to 100 kHz 1.8 mV to 55 V p-p (1 MΩ) 10 Hz to 100 kHz 33 µV + 2 mV/V 33 µV + 0.39 mV/V 91 µV + 4.3 mV/V 0.2 mV + 0.8 mV/V 0.24 mV + 2 mV/V 82 ps 82 ps 0.33 mV + 17 mV/V 0.4 mV + 31 mV/V 0.43 mV + 36 mV/V 0.53 mV + 57 mV/V 0.58 mV + 67 mV/V 0.0021 % + (t / 1000) % 0.000 36 % 0.12 mV + 23 mV/V 0.12 mV + 23 mV/V Fluke 5522A/SC1100 Fluke 5522A t = time in seconds
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 11 of 14 III. Fluid Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Gas Flow – Air & N2 Laminar Flow Sonic Flow Volumetric – Pipettes (0.01 to 50) SLPM (10 to 120) SLPM Up to 31 mL (31 to 50) mL 0.41 % 0.41 % 0.023 µL 0.1 µL Fluke Molbox standard Electronic balance, reference mass IV. Mechanical Parameter/Equipment Range CMC2, 5, 6 (±) Comments Pressure3 – Measure & Measuring Equipment Hydraulic Pneumatic (400 to 10 000) psig (4 to 200) ins H2O @ 60 °F (8 to 17) psia (-15 to 15) psig (-15 to 50) psig (> 50 to 150) psig (-15 to 100) psig (> 100 to 300) psig (-15 to 330) psig (> 330 to 1000) psig 0.17 psi + 0.000 17 psi/psi 0.008 in·H2O + 0.000 27 in·H2O/in·H2O 0.01 % 0.003 psig 0.0044 psig 0.008 % 0.0083 psi 0.008 % 0.027 psi 0.008 % Pressurements W2200/3HP Ametek PK II Mensor CPC6050 with sensor range (8 to 17) psia Mensor CPC6050 with sensor range (-15 to 15) psig Mensor CPC6050 with sensor range (-15 to 150) psig Mensor CPC6050 with sensor range (-15 to 300) psig Mensor CPC6050 with sensor range (-15 to 1000) psig
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 12 of 14 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Torque – Measure3 (2 to 20) ozf·in (2.5 to 25) lbf·in (25 to 75) lbf·in (10 to 100) lbf·ft (25 to 250) lbf·ft (100 to 1000) lbf·ft 0.32 % 0.59 % 1.2 % 0.59 % 0.32 % 0.59 % Mountz BMX20z Mountz BMX25i Jetco TED-75is-P Mountz LTT-100F Mountz BMX250F Mountz BMX 1000F Torque Transducers3 10 lbf·in to 250 lbf·ft 0.036 % Torque arms, Class 6 weights Scales3 Up to 4000 lb 0.82 x R Class 6 weights R = Unit Under Test resolution V. Thermodynamic Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure & Measuring Equipment3 (-197 to 420) °C (420 to 1000) °C 0.026 °C + 0.000 018 x TChange from -197 0.012 °C + 0.000 092 x TChange from 420 2560 thermometer w/ 5614 PRT 5624 PRT Temperature – Measure3 (-70 to 180) °C (10 to 60) °C 0.23 °C 0.12 °C Vaisala M170 with HMP77B Thunder Scientific 1200 Dewpoint – Measuring Equipment (-80 to < -50) °C (-50 to < 0) °C (0 to 20) °C (-20 to 20) °C 1.1 °C 0.18 °C 0.13 °C 0.14 °C Mitchell S8000RS chilled mirror hygrometer Thunder Scientific 1200
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 13 of 14 Parameter/Equipment Range CMC2, 6 (±) Comments Relative Humidity – Measuring Equipment (10 to 95) % RH 0.67 % RH Thunder Scientific 1200 Relative Humidity – Measure3 Up to 100 % RH 1.3 % RH Vaisala M170 with HMP77B VI. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 1 µHz to 21 MHz 0.58 µHz + 8.2 µHz/Hz HP 3325B Frequency – Measure3 1 mHz to 225 MHz 5.8 µHz + 4.1 µHz/Hz Agilent 53132A ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The measurands stated are generated using the indica ted instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measuran d in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, the value is defined as the percentage of reading ; L is the numerical value of the nominal length of the device measured in inches, unless otherwise noted.
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1486.02) 04/26/2024 Page 14 of 14 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
15ISO/IEC 17025:20 17; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.