SIMCO Electronics - Hampton
144 Research Drive, Suite A, 23666, Hampton, VA, United States
Visit website- Scope lines
- 18
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 18 scope lines.
A2LA certificate 1395.15 · 18 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | Sound Pressure Level; Acoustic Calibrators; Acoustic Level; Pistonphones | 74 to 130 dB |
| 2 | - | MicrophoneShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 2 of 17
Parameter/Equipment
Range
CMC2 (±)
Comments
Microphone Open Circuit
Sensitivity –
Microphone Electrostatic
Response
Weighting Networks –
A
B
C
D
Linear
Microphone Preamp
Frequency Response
(-60 to -24) dB re 1V/Pa
1” Microphone
½” Microphone
¼” Microphone
(0.02 to 2) kHz
(2 to 6.309) kHz
(6.309 to 20) kHz
(20 to 80) kHz
Frequency: 10 Hz to 20 kHz
Frequency: 10 Hz to 20 kHz
Frequency: 10 Hz to 20 kHz
Frequency: 10 Hz to 20 kHz
Frequency: 1 Hz to 200 kHz
(1 to 200 000) Hz
0.035 dB re 1V/Pa
0.074 dB re 1V/Pa
0.031 dB re 1V/Pa
0.17 dB
0.19 dB
0.22 dB
0.31 dB
0.013 dB
0.0041 dB
0.0019 dB
0.0055 dB
0.0019 dB
0.0074 dB
HBK 4228
HBK 4160 1.0”
HBK 4191 0.5”
HBK 4938 0.25”
NI PXI-4462
HBK 5001, 5935L
HP 3325B
NI PXI-4462
Mensor 15000
NI PXI-4462
HP 3325B
HP 3458A
HP 3325B
HP 3458A
II. Dimensional
Parameter/Equipment
Range CMC2, 6 (±) Comments
Calipers3
Up to 20 in
(20 to 60) in
(7.6 + 20L) µin
(7.6 + 38L) µin
Gage blocks,
master rings
Micrometers3 –
Linearity
Flatness
Parallelism
Up to 36 in
Up to 1 in Ø
9
(0.5 to 1) in
(8.9 + 5.4L) µin
6.5 µin
24 µin
Gage blocks
Optical flats
Ball checker set | 1 to 200000 Hz |
| 3 | - | Threaded Plugs; Cylindrical Gages; Gage Blocks; Ring Gages; Length StandardsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 3 of 17
Parameter/Equipment
Range CMC2, 6 (±) Comments
Threaded Plugs –
Major Diameter
Pitch Diameter
Up to 12 in
Up to 12 in,
(4 to 80) TPI
(19 + 4.1L) µin
(68 + 3.7L) µin
P&W USM,
gage blocks
Thread wires
Linear Indicators
(Dial, Test, LVDT’s)
Up to 2 in
22 µin
P&W USM
Flatness
Up to 1 in Ø9
6.5 µin
Optical flats
Cylindrical Gages
(Plain Pins, Plugs, Discs)
Up to 12 in
(7.0 + 2.6L) µin
P&W USM,
gage blocks
Gage Blocks
Up to 0.04 in
(0.04 to 4) in
(4 to 24) in
(2.0 + 1.9L) µin
(1.3 + 1.6L) µin
(2.9 + 1.5L) µin
Federal 130B-24
master gage blocks
Height Gages³
Up to 48 in
(31 + 2.6L) µin
Gage blocks
Ring Gages
(0.125 to 0.25) in
(0.250 to 1) in
(1 to 10) in
(7.7 + 2.5L) µin
(7.4 + 3.5L) µin
(17 + 3.2L) µin
P&W USM,
gage blocks
Length Standards
(0.5 to 8) in
(11 + 2.4L) µin
P&W USM, gage
blocks
Linear Scale Measurement
Up to 48 in increments
(32 + 0.58L) µin
Laser interferometer
Thread Wires
(4 to 80) TPI
8.8 µin
P&W USM,
gage blocks or master
cylinders | - |
| 4 | - | Surface Plates; DC Voltage; DC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 4 of 17
Parameter/Equipment
Range CMC2, 6 (±) Comments
Surface Plates3 –
Flatness
Repeat Reading
Up to 7 ft diagonal
(36 x 36) in
(6.7 + 0.58D) µin
28 µin
Renishaw XL-80 LI
Renishaw XC-80 TC
Angular
optics/straight edge
Repeatmeter
III. Electrical – DC/Low Frequency
Parameter/Equipment Range CMC2, 5, 6 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1000) V
8.7 µV/V + 0.4 µV
5.9 µV/V + 0.71 µV
4.2 µV/V + 2.8 µV
4.2 µV/V + 4.2 µV
5.9 µV/V + 42 µV
7.7 µV/V + 420 µV
Fluke 5720A
DC Voltage – Measure3
Digitize – Measure
3
(0 to 202) mV
(0.202 to 2.02) V
(2.02 to 20.2) V
(20.2 to 202) V
(202 to 1050) V
(0 to 1050) V
7.7 µV/V + 0.23 µV
3 µV/V + 0.35 µV
2.9 µV/V + 0.58 µV
4.7 µV/V + 35 µV
5 µV/V + 580 µV
57 µV/V + 31 mV
Fluke 8588A
DC Current – Generate3
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(0.22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(20 to 149.999) A
(150 to 1025) A
48 µA/A + 6.0 nA
43 µA/A + 7.0 nA
43 µA/A + 40 nA
54 µA/A + 0.7 µA
93 µA/A + 12 µA
0.38 mA/A + 0.37 mA
0.81 mA/A + 0.75 mA
0.36 %
0.35 %
Fluke 5720A
55XXA
[2] Floor spec.
doubles >30
seconds
Fluke 55XXA,
Fluke 5500A/COIL | - |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 5 of 17
Parameter/Equipment Range CMC2, 5, 6 (±) Comments
DC Current – Measure3
Digitize – Measure3
Shunt – Measure
3, 4
(0 to 20.2) µA
(20.2 to 202) µA
(0.202 to 2.02) mA
(2.02 to 20.2) mA
(20.2 to 202) mA
(0.202 to 2.02) A
(2.02 to 20.2) A
(20.2 to 30.2) A
(0 to 202) mA
(0.202 to 2.02) A
(2.02 to 20.2) A
(20.2 to 30.2) A
(20 to 100) A
28 µA/A + 4.6 pA
9.5 µA/A + 0.46 nA
8.8 µA/A + 4.6 nA
10 µA/A + 46 nA
38 µA/A + 1.2 µA
120 µA/A + 120 µA
200 µA/A + 0.46 mA
570 µA/A + 5.1 mA
55 µA/A + 9.2 µA
130 µA/A + 140 µA
210 µA/A + 2.4 mA
580 µA/A + 8 mA
0.023 %
Fluke 8588A
Fluke 5522A,
L&N 4221B,
Fluke 8588A
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 Ω to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
330 MΩ to 1.1 GΩ
31 µΩ/Ω + 0.000 78 Ω
23 µΩ/Ω + 0.0012 Ω
22 µΩ/Ω + 0.0011 Ω
22 µΩ/Ω + 0.0016 Ω
22 µΩ/Ω + 0.0016 Ω
22 µΩ/Ω + 0.016 Ω
22 µΩ/Ω + 0.016 Ω
22 µΩ/Ω + 0.16 Ω
22 µΩ/Ω + 0.16 Ω
25 µΩ/Ω + 1.6 Ω
25 µΩ/Ω + 1.6 Ω
47 µΩ/Ω + 23 Ω
0.010 % + 39 Ω
0.019 % + 1.9 kΩ
0.039 % + 2.3 kΩ
0.23 % + 0.078 MΩ
1.2 % + 0.39 MΩ
Fluke 55XXA | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 6 of 17
Parameter/Equipment Range CMC2, 5, 6 (±) Comments
Resistance – Generate3
Fixed Points
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
54 µΩ
95 µΩ/Ω + 11 µΩ
50 µΩ/Ω + 11 µΩ
2.3 µΩ/Ω + 11 µΩ
1.2 µΩ/Ω + 11 µΩ
0.1 µΩ/Ω + 11 µΩ
0.053 µΩ/Ω + 82 µΩ
8.5 µΩ/Ω + 82 µΩ
4.5 µΩ/Ω + 0.82 mΩ
0.85 µΩ/Ω + 0.82 mΩ
0.45 µΩ/Ω + 8.2 mΩ
0.11 µΩ/Ω + 8.2 mΩ
0.058 µΩ/Ω + 82 mΩ
20 µΩ/Ω + 82 mΩ
11 µΩ/Ω + 0.82 Ω
4 µΩ/Ω + 0.82 Ω
2.5 µΩ/Ω + 8.2 Ω
1.0 µΩ/Ω + 8.2 Ω
Fluke 5720A
Resistance – Measure3
(0 to 2.02) Ω
(2.02 to 20.2) Ω
(20.2 to 202) Ω
(0.202 to 2.02) kΩ
(2.02 to 20.2) kΩ
(20.2 to 202) kΩ
(0.202 to 2.02) MΩ
(2.02 to 20.2) MΩ
(20.2 to 202) MΩ
(0.202 to 2.02) GΩ
(202 to 20.2) GΩ
13 µΩ/Ω + 4.6 µΩ
8.9 µΩ/Ω + 16 µΩ
8.3 µΩ/Ω + 58 µΩ
8.2 µΩ/Ω + 580 µΩ
8.3 µΩ/Ω + 5.8 mΩ
8.4 µΩ/Ω + 58 mΩ
9.5 µΩ/Ω + 1.2 Ω
13 µΩ/Ω + 120 Ω
45 µΩ/Ω + 12 kΩ
580 µΩ/Ω + 1.2 MΩ
610 µΩ/Ω + 12 MΩ
Fluke 8588A
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.99) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(0.33 to 1.0999) mF
0.48 % + 0.0097 nF
0.41 % + 0.0097 nF
0.39 % + 0.0097 nF
0.23 % + 0.015 nF
0.19 % + 0.078 nF
0.21 % + 0.078 nF
0.20 % + 0.23 nF
0.20 % + 0.0058 µF
0.20 % + 0.0062 µF
0.20 % + 0.0097 µF
0.33 % + 0.024 µF
0.42 % + 0.078 µF
0.36 % + 0.23 µF
0.35 % + 0.0058 mF
Fluke 55XXA | ||
| 7 | - | capacitance; oscilloscopes; sine amplitude; sine flatness; square wave; time marker output; edge rise timeShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 7 of 17
Parameter/Equipment Range CMC2, 5, 6 (±) Comments
Capacitance – Measure3
(0 to 2.02) nF
(2.02 to 20.2) nF
(20.2 to 202) nF
(0.202 to 2.02) µF
(2.02 to 20.2) µF
(20.2 to 202) µF
(0.202 to 2.02) mF
(2.02 to 20.2) mF
(20.2 to 202) mF
1200 µF/F + 1.2 pF
700 µF/F + 2.3 pF
470 µF/F + 10 pF
470 µF/F + 0.12 nF
470 µF/F + 1.2 nF
700 µF/F + 12 nF
700 µF/F + 0.12 µF
810 µF/F + 1.2 µF
810 µF/F + 12 µF
Fluke 8588A
Oscilloscopes3 –
Level Sine Amp –
50 kHz Reference
Level Sine Flatness –
5 mV to 5.5 V
Relative to 50 kHz
Reference
Square Wave –
(0.010 to 10) kHz
Into 50 Ω
Into 1 MΩ, 1 kHz
Into 1 MΩ, >1 kHz
DC
Into 50 Ω
Into 1 MΩ
Time Marker Output
into 50 Ω
Edge Rise Time
5 mV to 5.5 Vp-p
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
1 mV to 6.6 V
p-p
1 mV to 130 Vp-p
1 mV to 130 Vp-p
(0 to 6.6) Vp-p
(0 to 130) Vp-p
20 ns to 20 ms
(0.05 to 5) s
1 kHz to 10 MHz
1.6 % of output
1.2 % of output
1.6 % of output
3.1 % of output
4.7 % of output
0.25 % of output
0.10 % of output
0.25 % of output
2.6 mV
0.51 mV
2.5 parts in 10
6
51 parts in 104
40 ps
Fluke 55XXA | 0 to 130 Vp-p |
| 8 | - | thermocouplesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 8 of 17
Parameter/Equipment Range CMC2 (±)
Comments
Electrical Simulation of
Thermocouples3 –
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.40 °C
0.14 °C
0.13 °C
0.14 °C
0.18 °C
0.25 °C
0.17 °C
0.15 °C
0.15 °C
0.20 °C
0.28 °C
0.16 °C
0.14 °C
0.24 °C
0.32 °C
0.51 °C
0.20 °C
0.14 °C
0.13 °C
Fluke 55XXA
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate3
(0.22 to 2.2) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1MHz
0.024 % + 4 µV
0.0090 % + 4 µV
0.0080 % + 4 µV
0.020 % + 4 µV
0.050 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.27 % + 20 µV
Fluke 5720A | - |
| 9 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 9 of 17
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate3
(cont)
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.025 % + 4 µV
0.0090 % + 4 µV
0.0080 % + 4 µV
0.020 % + 4 µV
0.050 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.27 % + 20 µV
0.024 % + 12 µV
0.0090 % + 7 µV
0.0080 % + 7 µV
0.022 % + 7 µV
0.048 % + 17 µV
0.095 % + 20 µV
0.16 % + 25 µV
0.33 % + 45 µV
0.024 % + 40 µV
0.0090 % + 15 µV
0.0045 % + 8 µV
0.0075 % + 10 µV
0.012 % + 30 µV
0.044 % + 80 µV
0.11 % + 200 µV
0.18 % + 300 µV
0.024 % + 400 µV
0.0090 % + 150 µV
0.0045 % + 50 µV
0.0075 % + 100 µV
0.013 % + 200 µV
0.031 % + 600 µV
0.11 % + 2 mV
0.17 % + 3.2 mV
0.044 % + 4 mV
0.0090 % + 1.5 mV
0.0052 % + 0.6 mV
0.0080 % + 1 mV
0.020 % + 2.5 mV
0.092 % + 16 mV
0.44 % + 40 mV
0.88 % + 80 mV
Fluke 5720A | See scope document |
| 10 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 10 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage – Generate3
(cont)
(220 to 1100) V
(220 to 750) V
(15 to 40) Hz
(40 to 50) Hz
50 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.095 % + 16 mV
0.028 % + 4 mV
0.037 % + 3.5 mV
0.030 % + 6 mV
0.10 % + 11 mV
0.080 % + 11 mV
0.30 % + 45 mV
Fluke 5720A
Fluke 5725A
AC Voltage – Generate3
Wideband
Up to 1.1 mV
(1.1 to 3) mV
(3 to 11) mV
(11 to 33) mV
(33 to 110) mV
(110 to 330) mV
(0.33 to 1.1) V
(1.1 to 3.5) V
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
10 Hz to 30 MHz
0.80 % + 2 µV
0.70 % + 3 µV
0.70 % + 8 µV
0.60 % + 16 µV
0.60 % + 40 µV
0.50 % + 0.1 mV
0.50 % + 0.4 mV
0.40 % + 0.5 mV
Fluke 5720A
AC Voltage – Generate3
Wideband Flatness
Up to 1.1 mV
(1.1 to 3) mV
3 mV to 3.5 V
(0.30 to 120) kHz
(0.120 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(0.30 to 120) kHz
(0.120 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(0.30 to 120) kHz
(0.120 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
0.10 %
0.20 % + 3 µV
0.40 % + 3 µV
0.60 % + 3 µV
1.5 % + 15 µV
0.10 %
0.10 % + 3 µV
0.30 % + 3 µV
0.50 % + 3 µV
1.5 % + 3 µV
0.10 %
0.10 % + 3 µV
0.20 % + 3 µV
0.40 % + 3 µV
1.0 % + 3 µV
Fluke 5720A | See scope document |
| 11 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 11 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage – Measure3
(0.014 to 12.12) mV
(12.12 to 121.2) mV
121.2 mV to 12.12 V
(12.12 to 121.2) V
(121.2 to 1050) V
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
250 µV/V + 1.3 µV
330 µV/V + 1.3 µV
340 µV/V + 1.3 µV
0.3 % + 1.3 µV
1.0 % + 4.6 µV
2.0 % + 4.6 µV
68 µV/V + 0.58 µV
110 µV/V + 0.58 µV
210 µV/V + 1.2 µV
510 µV/V + 5.8 µV
0.2 % + 35 µV
1.0 % + 120 µV
1.5 % + 580 µV
4.0 % + 1.2 mV
8.0 % + 1.2 mV
15 % + 1.2 mV
65 µV/V + 58 µV
110 µV/V + 58 µV
210 µV/V + 120 µV
510 µV/V + 580 µV
0.2 % + 3.5 mV
1.0 % + 12 mV
1.5 % + 58 mV
4.0 % + 120 mV
8.0 % + 120 mV
15 % + 120 mV
70 µV/V + 0.58 mV
91 µV/V + 0.58 mV
210 µV/V + 1.2 mV
510 µV/V + 5.8 mV
0.35 % + 58 mV
1.1 % + 580 mV
90 µV/V + 29 mV
91 µV/V + 29 mV
210 µV/V + 29 mV
510 µV/V + 120 mV
Fluke 8588A | See scope document |
| 12 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 12 of 17
Parameter/Range Frequency CMC2, 5 (±) Comments
AC Current – Generate4
@ 60 Hz
(20 to 100) A
0.10 % of setting
Fluke 5522A w/
Valhalla 2555A
AC Current – Generate4
@ 400 Hz
(20 to 100) A
0.10 % of setting
Fluke 5522A w/
Valhalla 2555A
AC Current – Generate3 @
1kHz
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20 to 100) A
(3 to 11) A
(11 to 20.5) A
0.13 % + 0.10 µA
0.11 % + 0.20 µA
0.040 % + 3.0 µA
0.039 % + 27 µA
0.051 % + 0.10 mA
0.014 % + 0.59 mA
0.021 % + 2.0 mA
0.048 % + 5.0 mA
0.70 % of setting
0.041 % + 2.1 mA
0.061 % + 5.6 mA
Fluke 55XXA
Fluke 55XXA w/
Valhalla 2555A
Fluke 55XXA
AC Current – Measure3
(0.04 to 20.2) µA
20.2 µA to 20.2 mA
(20.2 to 202) mA
202 mA to 2.02 A
(2.02 to 20.2) A
(20.2 to 30.2) A
1 Hz to 30 kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 10 kHz
1 Hz to 2 kHz
(2 to 10) kHz
2000 µA/A + 2.9 nA
260 µA/A + 0.58 µA
510 µA/A + 0.58 µA
720 µA/A + 0.58 µA
4 mA/A + 1.2 µA
260 µA/A + 5.8 µA
500 µA/A + 5.8 µA
700 µA/A + 5.8 µA
260 µA/A + 120 µA
510 µA/A + 120 µA
710 µA/A + 120 µA
800 µA/A + 580 µA
0.8 mA/A + 14 mA
1.2 mA/A + 14 mA
Fluke 8588A | See scope document |
| 13 | - | Nitrogen GasShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 13 of 17
IV. Mechanical
Parameter/Equipment Range CMC2, 6, 8 (±) Comments
Pressure – Measuring
Equipment
(0.7 to 50.8) psi
(1.4 to 253.8) psi
(14.5 to 1102.3) psi
(0.2 to 18.7) psi
(1.7 to 75.6) psi
(1 to 742.1) psi
(100 to 3000) psi
(1.2 to 55.1) psi
(3.6 to 275.6) psi
(14.5 to 1102.3) psi
(0.2 to 18.7) psi
(1.7 to 75.7) psi
(0 to 742.1) psi
(0 to 3000) psi
(0 to 10 000) psi
0.0016 % + 0.000 095 psi
0.0020 % + 0.000 050 psi
0.0036 % + 0.000 17 psi
0.0018 % + 0.000 004 9 psi
0.0019 % + 0.000 017 psi
0.0023 % + 0.000 17 psi
0.0028 % + 0.0058 psi
0.0015 % + 0.000 099 psi
0.0018 % + 0.000 084 psi
0.0036 % + 0.000 33 psi
0.018 % + 0.000 004 2 psi
0.0019 % + 0.000 017 psi
0.0023 % + 0.000 17 psi
0.011 % + 0.11 psi
0.011 % + 0.37 psi
DHI PG-7601
Pressure Gauges –
Hydraulic
(100 to 10 000) psig
(500 to 50 000) psig
0.021 %
0.021 %
DHI 5306 S
Vacuum – Measuring
Equipment, Nitrogen
Gas
Up to 1 Torr
Up to 10 Torr
Up to 100 Torr
0.087 %
0.087 %
0.087 %
MKS 390HA-
00010SP05
Force – Measuring
Equipment
Tension
Compression
(5 to 500) lbf
(97 to 2000) lbf
(200 to 10 000) lbf
(5 to 500) lbf
(97 to 2000) lbf
(200 to 10 000) lbf
(2180 to 50 000) lbf
0.012 % + 0.044 lbf
0.006 % + 0.056 lbf
0.0061 % + 0.34 lbf
0.012 % + 0.044 lbf
0.006 % + 0.076 lbf
0.006 % + 0.14 lbf
0.006 % + 1.3 lbf
Sensotronics 60001-500
Morehouse 300-2K
BLH C3P1
Sensotronics 60001-500
Morehouse 300-2K
Morehouse 5K-10K
Morehouse 25K-50K | See scope document |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 14 of 17
Parameter/Equipment Range CMC2, 6, 8 (±) Comments
Torque – Wrenches &
Screwdrivers
(2 to 20) lbf∙in
(20 to 240) lbf∙in
(10 to 100) lbf∙ft
(200 to 2000) lbf∙ft
0.14 %
0.29 %
0.12 %
0.31 %
AKO torque system
Dynamic Acceleration –
Measure
5 Hz to 10 kHz;
100 g peak
2.4 %
UD 106A
Sunstrand
979-0900-001A
Agilent 3458A
Dynamic Acceleration
Linearity – Measure
(0.5 to 100) g peak;
200 Hz
0.71 %
UD 106A
Sunstrand 979-0900-001A
Agilent 3458A
V. Optical Quantities
Parameter/Equipment Range CMC2, 5 (±) Comments
Optical Attenuator
Nonlinearity – Measure
850 nm
1310 nm
0 dBm
-10 dBm
-20 dBm
-30 dBm
-40 dBm
-50 dBm
0 dBm
-10 dBm
-20 dBm
-30 dBm
-40 dBm
-50 dBm
0.017 dB
0.016 dB
0.015 dB
0.019 dB
0.023 dB
0.043 dB
0.0070 dB
0.0068 dB
0.011 dB
0.018 dB
0.018 dB
0.013 dB
HP 81551MM laser source
w/ Keysight 81624B optical
head
Agilent 81655A laser
source w/ Keysight 81624B
optical head | ||
| 15 | - | Optical AttenuatorShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 15 of 17
Parameter/Equipment Range CMC2, 5 (±) Comments
Optical Attenuator
Nonlinearity – Measure‘
(cont.)
1550 nm
0 dBm
-10 dBm
-20 dBm
-30 dBm
-40 dBm
-50 dBm
0.0066 dB
0.0065 dB
0.020 dB
0.022 dB
0.021 dB
0.030 dB
Agilent 81652A laser
source w/ Keysight 81624B
optical head
Optical Absolute Power –
Measure
-20 dBm @ 850 nm
-20 dBm @ 1310 nm
-20 dBm @ 1550 nm
0.064 dB
0.052 dB
0.054 dB
HP 81551MM laser source
w/ HP 8158B optical
attenuator w/ Keysight
81624B optical head
Agilent 81655A laser
source w/ Agilent 8156A
optical attenuator w/
Keysight 81624B optical
head
Agilent 81652A laser
source w/ Agilent 8156A
optical attenuator w/
Keysight 81624B optical
head
Optical Absolute Power –
Measure
-10 dBm @ 850 nm
-10 dBm @ 1310 nm
-10 dBm @ 1550 nm
0.069 dB
0.049 dB
0.049 dB
HP 81551MM laser source
w/ HP 8158B optical
attenuator w/ Keysight
81624B optical head
Agilent 81655A laser
source w/ Agilent 8156A
optical attenuator w/
Keysight 81624B optical
head
Agilent 81652A laser
source w/ Agilent 8156A
optical attenuator w/
Keysight 81624B optical
head | - |
| 16 | - | Temperature – Measuring Equipment; Relative Humidity – Measuring Equipment; Frequency – Reference Signal; Frequency – Measuring Equipment; Frequency – MeasureShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 16 of 17
VI. Thermodynamics
Parameter/Equipment Range CMC2, 8 (±) Comments
Temperature –
Measuring Equipment
(-196 to -38) °C
(-38 to 0) °C
(0 to 419.5) °C
(419.5 to 660) °C
0.0058 °C
0.0056 °C
0.0067 °C
0.017 °C
ISOTECH microK 250
L&N 8167-25B
Hart 9122
LN2
Liquid Bath
Dry Well
Relative Humidity –
Measuring Equipment
(10 to 65) % RH
(65 to 95) % RH
0.53 % RH
0.58 % RH
Thunder Scientific 2500
Thunder Scientific 2500
VII. Time & Frequency
Parameter/Equipment Frequency CMC2, 8 (±) Comments
Frequency – Reference
10 MHz Reference
Signal
3.6 x 10-11 Hz/Hz
Fluke 910R
Parameter/Equipment Frequency CMC2, 8 (±) Comments
Frequency – Measuring
Equipment
DC to 20 MHz
20 MHz to 20 GHz
13 x 10-10 Hz/Hz + 50 µHz
5.5 x 10-5 Hz/Hz
Fluke 910R
HP 3325B
HP 8340A
Frequency – Measure
DC to 3 GHz
1.3 x 10-6 /Hz + 50 µHz
Fluke 910R
Agilent 53131A
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service. | See scope document |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 17 of 17
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and
Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level
of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Based on using the standard at the temperature the Fluke 5522A was calibrated (tcal ± 5 °C) and assuming
the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5
°C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 °C of use.
5 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading
plus a fixed floor specification.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is the resolution of the unit under test; D is the numerical value of the nominal diagonal length of the
surface plate in inches; % is defined as the percent of reading, unless otherwise noted.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 Ø is Diameter in inches | ||
| 18 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ACR Technical ServicesNewport News, VA · ~23 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TRESCAL, INC. - Richmond, VAProvidence Forge, VA · ~77 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hoffer Calibration Services, LLC (a Subsidiary of Hoffer Flow Controls, Inc.)Elizabeth City, NC · ~81 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Norfolk, NCELIZABETH CITY, NC · ~81 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SP HB Instrument Calibration LaboratoryPocomoke City, MD · ~135 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.