Futek Advanced Sensor Technology
19 Morgan, 92618, Irvine, CA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2412.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2412.01) 08/27/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Torque – Measure
(0.10 to 25) lbfꞏin
(890 to 10 000) lbfꞏin
(2082 to 24 000) lbfꞏin
0.072 % FS
0.066 % FS
0.089 % FS
Torque cells
Torque – Measuring
Equipment
(0.0125 to 25) lbfꞏin
(5 to 885) lbfꞏin
(885 to 4000) lbfꞏin
(4000 to 24 000) lbfꞏin
0.044 % FS
0.048 % FS
0.032 % FS
0.053 % FS
Torque arms and weights
Pressure – Measure
(0 to 1515) psia
(300 to 10 000) psig
0.014 % FS
0.047 % FS
Reference pressure cells
Mensor CPC6050
CPP 1000X
Rotational Speed, RPM
– Measuring Equipment
(120 to 12 000) rpm
0.057 % FS
Tachometer
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
DC Voltage – Measure
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
0.0034 % FS
0.0008 % FS
0.0005 % FS
0.0019 % FS
Fluke 8508A
DC Current – Measure
(0 to 10) mA
(10 to 100) mA
0.0067 % FS
0.012 % FS
Fluke 8508A
Resistance – Measure
100 Ω to 10 kΩ
0.015 % FS
Fluke 8508A
DC Voltage Ratio –
Measure
(0.05 to 10) mV/V
0.018 % FS
mV/V simulator, Vishay
precision calibrator
____________________________________________
1
This laboratory offers commercial calibration service. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2412.01) 08/27/2025 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, “% FS” means percentage of Full Scale unless otherwise noted.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Anko ElectronicsAnaheim, CA · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~21 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~23 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Spektra Labs by APS DynamicsSan Juan Capistrano, CA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - SANTA FE SPRINGSSanta Fe Springs, CA · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.