Registers refreshed 2026-11-08.See refresh dates
United States

Futek Advanced Sensor Technology

19 Morgan, 92618, Irvine, CA, United States

Visit website
A2LA 2412.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2412.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2412.01) 08/27/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Torque – Measure (0.10 to 25) lbfꞏin (890 to 10 000) lbfꞏin (2082 to 24 000) lbfꞏin 0.072 % FS 0.066 % FS 0.089 % FS Torque cells Torque – Measuring Equipment (0.0125 to 25) lbfꞏin (5 to 885) lbfꞏin (885 to 4000) lbfꞏin (4000 to 24 000) lbfꞏin 0.044 % FS 0.048 % FS 0.032 % FS 0.053 % FS Torque arms and weights Pressure – Measure (0 to 1515) psia (300 to 10 000) psig 0.014 % FS 0.047 % FS Reference pressure cells Mensor CPC6050 CPP 1000X Rotational Speed, RPM – Measuring Equipment (120 to 12 000) rpm 0.057 % FS Tachometer II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3, 6 (±) Comments DC Voltage – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V 0.0034 % FS 0.0008 % FS 0.0005 % FS 0.0019 % FS Fluke 8508A DC Current – Measure (0 to 10) mA (10 to 100) mA 0.0067 % FS 0.012 % FS Fluke 8508A Resistance – Measure 100 Ω to 10 kΩ 0.015 % FS Fluke 8508A DC Voltage Ratio – Measure (0.05 to 10) mV/V 0.018 % FS mV/V simulator, Vishay precision calibrator ____________________________________________ 1 This laboratory offers commercial calibration service.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2412.01) 08/27/2025 Page 3 of 3 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, “% FS” means percentage of Full Scale unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

19 Morgan, Irvine, CA, 92618, US

33.68570, -117.82598

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.