Constellation Powerlabs - Madison, PA

680 Waltz Mill Road, Interstate 70, 15663, Madison, PA, United States

Visit website
A2LA 2044.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 2044.03 · 13 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 2 of 12 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage3 – Measure (0 to 120) mV 100 mV to 1.2 V (1 to 12) V (10 to 120) V (100 to 1050) V 7.1 µV/V + 0.3 µV 6 µV/V + 0.3 µV 6 µV/V + 0.5 µV 8 µV/V + 30 µV 8 µV/V + 120 µV Long scale multimeter DC Voltage – Generate (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 7.5 µV/V + 0.4 µV 5 µV/V + 0.7 µV 3.5 µV/V + 2.5 µV 3.5 µV/V + 4.4 µV 5 µV/V + 40 µV 6.5 µV/V + 400 µV Primary multi-function calibrator DC Current – Measure (10 to 120) µA 100 µA to 1.2 mA (1 to 12) mA (10 to 120) mA 100 mA to 1.05 A 25 µA/A + 0.8 nA 25 µA/A + 5 nA 25 µA/A + 50 nA 40 µA/A + 500 nA 0.011 % + 10 µA Long scale multimeter DC Current – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 15) A (15 to 20.5) A 40 µA/A + 6 nA 35 µA/A + 7.2 nA 35 µA/A + 41 nA 45 µA/A + 0.7 µA 80 µA/A + 12 µA 0.036 % + 480 µA 0.1 % + 750 µA 0.1 % + 880 µA Primary multi-function calibrator Resistance – Measure (0 to 12) Ω (10 to 120) Ω (100 to 1200) Ω (1 to 12) kΩ (10 to 120) kΩ 100 kΩ to 1.2 MΩ (1 to 12) MΩ (10 to 120) MΩ 100 MΩ to 1.2 GΩ 18 µΩ/Ω + 50 µΩ 15 µΩ/Ω + 500 µΩ 13 µΩ/Ω + 500 µΩ 13 µΩ/Ω + 5 mΩ 13 µΩ/Ω + 50 mΩ 18 µΩ/Ω + 2 Ω 53 µΩ/Ω + 110 Ω 0.05 % + 1.9 kΩ 0.5 % + 50 kΩ Long scale multimeter
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 3 of 12 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Resistance – Generate, Fixed Points 0.0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 55 µΩ 0.011 % 98 µΩ/Ω 23 µΩ/Ω 23 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω 8.5 µΩ/Ω 8.5 µΩ/Ω 8.5 µΩ/Ω 8.5 µΩ/Ω 11 µΩ/Ω 11 µΩ/Ω 20 µΩ/Ω 21 µΩ/Ω 40 µΩ/Ω 47 µΩ/Ω 100 µΩ/Ω Primary multi-function calibrator Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure (1 to 12) mV (12 to 120) mV 120 mV to 1.2 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz 0.03 % + 3 µV 0.02 % + 1.1 µV 0.03 % + 1.1 µV 0.1 % + 1.1 µV 0.5 % + 1.1 µV 4 % + 2 µV 72 µV/V + 4 µV 72 µV/V + 2 µV 0.014 % + 2 µV 0.033 % + 2.5 µV 0.08 % + 2 µV 0.3 % + 10 µV 1 % + 10 µV 1.5 % + 10 µV 72 µV/V + 40 µV 72 µV/V + 20 µV 0.014 % + 20 µV 0.03 % + 20 µV 0.08 % + 20 µV 0.3 % + 100 µV 1 % + 100 µV 1.5 % + 100 µV Long scale multimeter
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 4 of 12 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure (cont) (1.2 to 12) V (12 to 120) V (120 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 72 µV/V + 0.4 mV 72 µV/V + 0.2 mV 0.014 % + 0.2 mV 0.03 % + 0.2 mV 0.08 % + 0.2 mV 0.3 % + 1 mV 1 % + 1 mV 1.5 % + 1 mV 0.02 % + 4 mV 0.02 % + 2 mV 0.02 % + 2 mV 0.04 % + 2 mV 0.12 % + 2 mV 0.4 % + 10 mV 1.5 % + 10 mV 0.04 % + 40 mV 0.04 % + 20 mV 0.06 % + 20 mV 0.12 % + 20 mV 0.3 % + 20 mV Long scale multimeter AC Voltage – Generate (0.22 to 2.2) mV (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.025 % + 4 µV 91 µV/V + 4 µV 90 µV/V + 4 µV 0.02 % + 4 µV 0.053 % + 5 µV 0.11 % + 10 µV 0.14 % + 20 µV 0.27 % + 20 µV 0.028 % + 4 µV 94 µV/V + 4 µV 84 µV/V + 4 µV 0.02 % + 4 µV 0.05 % + 5 µV 0.11 % + 10 µV 0.14 % + 20 µV 0.27 % + 20 µV Primary multi-function calibrator with precision amplifier
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 5 of 12 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Generate (cont) (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (220 to 250) V (220 to 1100) V (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.024 % + 12 µV 91 µV/V + 7 µV 81 µV/V + 7 µV 0.02 % + 8 µV 0.046 % + 17 µV 0.09 % + 20 µV 0.14 % + 25 µV 0.27 % + 45 µV 0.024 % + 44 µV 90 µV/V + 18 µV 48 µV/V + 8 µV 80 µV/V + 12 µV 0.011 % + 35 µV 0.042 % + 80 µV 0.1 % + 200 µV 0.17 % + 300 µV 0.024 % + 420 µV 90 µV/V + 150 µV 45 µV/V + 80 µV 75 µV/V + 140 µV 0.01 % + 350 µV 0.028 % + 600 µV 0.1 % + 2000 µV 0.15 % + 3200 µV 0.024 % + 4.1 mV 91 µV/V + 1.5 mV 53 µV/V + 0.8 mV 82 µV/V + 1.5 mV 0.015 % + 3.4 mV 0.09 % + 16 mV 0.44 % + 40 mV 0.8 % + 80 mV 0.03 % + 16 mV 71 µV/V + 3.7 mV 90 µV/V + 4.5 mV 0.017 % + 6 mV 0.06 % + 11 mV 0.06 % + 11 mV 0.23 % + 45 mV Primary multi-function calibrator with precision amplifier Primary multi-function calibrator Primary multi-function calibrator with precision amplifier
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 6 of 12 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current – Measure (12 to 120) µA 120 µA to 1.2 mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1) A (0.04 to 0.1999) A (0.2 to 0.9999) A (1 to 20) A (20 to 5000) A (5 to 17) kA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (20 to 500) Hz (20 to 500) Hz (20 to 500) Hz 60 Hz 60 Hz 0.4 % + 30 nA 0.15 % + 30 nA 0.06 % + 30 nA 0.06 % + 30 nA 0.4 % + 200 nA 0.15 % + 200 nA 0.06 % + 200 nA 0.03 % + 200 nA 0.4 % + 2 µA 0.15 % + 2 µA 0.06 % + 2 µA 0.03 % + 2 µA 0.4 % + 20 µA 0.15 % + 20 µA 0.06 % + 20 µA 0.03 % + 20 µA 0.4 % + 200 µA 0.16 % + 200 µA 0.08 % + 200 µA 0.1 % + 200 µA 0.15 % 0.081 % 0.051 % 0.08 % 0.38 % Long scale multimeter Precision current monitor Primary current transformers & precision current monitor
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 7 of 12 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current – Generate (10 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.025 % + 16 nA 0.016 % + 10 nA 0.012 % + 8 nA 0.028 % + 12 nA 0.11 % + 65 nA 0.025 % + 40 nA 0.016 % + 35 nA 0.012 % + 35 nA 0.02 % + 110 nA 0.11 % + 650 nA 0.025 % + 400 nA 0.016 % + 350 nA 0.012 % + 350 nA 0.02 % + 550 nA 0.11 % + 5000 nA 0.025 % + 4 µA 0.016 % + 3.5 µA 0.012 % + 2.5 µA 0.02 % + 3.5 µA 0.11 % + 10 µA 0.026 % + 39 µA 0.045 % + 80 µA 0.7 % + 160 µA 0.046 % + 170 µA 0.095 % + 380 µA 0.36 % + 750 µA 0.12 % + 5000 µA 0.15 % + 5000 µA 3 % + 5000 µA Precision multi-function calibrator Precision multi-function calibrator with precision amplifier Precision multi-function calibrator Phase – Generate3 (0 to 90)° (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.1° 0.25° 0.5° 2.5° 5° 10° Precision multi-function calibrator with phase generation
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 8 of 12 Parameter/Equipment Range CMC2, 6 (±) Comments Electrical Calibration of Thermocouple Devices3 – Type E Type J Type K Type R Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -30) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.5 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C 0.27 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.4 °C 0.57 °C 0.35 °C 0.33 °C 0.4 °C 0.47 °C 0.36 °C 0.37 °C 0.46 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Precision multi-function calibrator with temperature generation
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 9 of 12 III. Mechanical Parameter/Equipment Range CMC2, 4, 9 (±) Comments Gage Pressure (0 to 1000) psig (150 to 830) psig (830 to 1080) psig (1080 to 1330) psig (1330 to 1500) psig (1500 to 8650) psig (8650 to 10 900) psig (10 900 to 13 150) psig (13 150 to 15 000) psig (10 000 to 40 000) psig 0.27 psig 0.026 % 0.027 % 0.028 % 0.029 % 0.031 % 0.032 % 0.033 % 0.034 % 11 psig Precision pressure calibrator Primary deadweight tester Precision pressure calibrator Torque Transducers (5 to 250) lbf·ft (5 to 1000) lbf·ft 0.07 % 0.086 % Class F weights mounted on a precision torque arm Torque Wrenches3 (5 to 1000) lbf·ft 0.7 % Precision torque transducer system Mass – Measure, Fixed Points 1 mg 2 mg 3 mg 5 mg 10 mg 20 mg 30 mg 50 mg 100 mg 200 mg 300 mg 500 mg 1 g 2 g 3 g 5 g 10 g 20 g 30 g 50 g 100 g 200 g 300 g 500 g 1000 g 2000 g 0.0033 mg 0.0033 mg 0.0033 mg 0.0033 mg 0.0069 mg 0.0069 mg 0.0069 mg 0.0069 mg 0.0088 mg 0.0088 mg 0.0088 mg 0.0089 mg 0.0081 mg 0.0089 mg 0.0085 mg 0.011 mg 0.024 mg 0.025 mg 0.024 mg 0.032 mg 0.077 mg 0.11 mg 0.11 mg 0.42 mg 0.46 mg 0.94 mg Double substitution method comparison to Ultra Class standard weights using a precision balance
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 10 of 12 Parameter/Equipment Range CMC2 (±) Comments Scales & Balances3 (2 to 500) mg 500 mg to 5 g (5 to 20) g (20 to 50) g (50 to 100) g (100 to 200) g (200 to 500) g (0.5 to 1) kg (1 to 2) kg (2 to 3) kg (3 to 5) kg (5 to 10) kg (10 to 32) kg 0.0013 mg 0.007 mg 0.03 mg 0.064 mg 0.13 mg 0.24 mg 0.61 mg 1.5 mg 2.5 mg 10 mg 0.15 g 0.2 g 0.36 g Reference weights up to 32 kg Force3 – Compression & Tension – Measure (40 to 1000) lbf (1001 to 2000) lbf (2001 to 5000) lbf (5001 to 10 000) lbf (10 001 to 25 000) lbf (25 001 to 50 000) lbf (50 001 to 100 000) lbf 0.52 lbf 1.1 lbf 1.4 lbf 2.6 lbf 6.3 lbf 13 lbf 25 lbf Precision Load Cells & system IV. Thermodynamics Parameter/Equipment Range CMC2, 9 (±) Comments Temperature – Measure (-190 to 660) °C (200 to 1000) °C 0.044 °C 0.9 °C Precision thermometer with reference SPRT, precision temperature baths & furnace Precision temperature baths & furnace Temperature – Measuring Equipment, Thermocouples7 Type E Type J Type K Type N Type T Type J Type K (20 to 660) °C (50 to 660) °C (50 to 660) °C (50 to 660) °C (50 to 350) °C (200 to 700) °C (200 to 700) °C 0.6 °C 0.6 °C 0.61 °C 0.6 °C 0.6 °C 1.1 °C 1.1 °C Blackstack, SPRT, precision temperature baths & furnace Type S thermocouple, indicator, baths&furnaces
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 11 of 12 Parameter/Equipment Range CMC2, 9 (±) Comments Infrared Temperature - Measuring Equipment 3 (-15 to 120) °C (120 to 200) °C (200 to 350) °C (350 to 500) °C 0.67 °C 1 °C 1.6 °C 2.2 °C Primary infrared temperature blackbody sources ε = 0.9 to 1.0 λ = (8 to 14) µm V. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 0.01 Hz to 2 MHz 2.5 µHz/Hz + 5 μHz Precision multi-function calibrator Frequency – Measure (1 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 10) MHz (10 to 100) MHz (100 to 225) MHz 225 MHz to 1 GHz (1 to 3) GHz 6.6 µHz 20 µHz 130 µHz 1.2 mHz 9.3 mHz 9.3 mHz 2.4 mHz 5.1 mHz 23 mHz 65 mHz Precision frequency counter referenced to the GPS ____________________________________________ 1 This laboratory offers commercial and field calibration service where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2044.03) 09/08/2025 Page 12 of 12 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, R is the resolution of the device under test, and % is the percentage of the reading. 5 Uncertainties for metric micrometers and calipers up to 900 mm are available upon request. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 The CMC associated with Temperature – Measuring Equipment, Thermocouples does not include inhomogeneity of the test thermocouple. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
13ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

680 Waltz Mill Road, Interstate 70, Madison, PA, 15663, US

40.24729, -79.67726

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.