Controls Service

Livonia , MI, United States

Visit website
A2LA 1740.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
8
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 1740.01 · 8 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1740.01) 06/18/2025 Page 2 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Generate3 Source Simulate (0 to 22) mA (0 to 22) mA 0.013 % + 4 µA 0.024 % + 81 µA Fluke 75x calibrator DC Current – Measure (0 to 50) mA 0.01 % + 0.001 mA Fluke 7526A DC Current – Measure3 (0 to 30) mA (30 to 100) mA 0.013 % + 6 µA 0.012 % + 27 µA Fluke 75x calibrator Resistance – Generate (5 to 400) Ω (400 to 4000) Ω 0.015 Ω 0.3 Ω Fluke 7526A Resistance – Generate3 (0 to 10) Ω (10 to 100) Ω (0.10 to 1.0) kΩ (1.0 to 10) kΩ 0.012 % + 0.012 Ω 0.011 % + 0.024 Ω 0.023 % + 0.24 Ω 0.023 % + 3.5 Ω Fluke 75x calibrator Resistance – Generate3 (20 to 1121) Ω 0.023 % + 0.13 mΩ General resistance decade box Resistance – Measure (0 to 400) Ω (400 to 4000) Ω 0.0021 % + 0.004 Ω 0.0021 % + 0.04 Ω Fluke 7526A Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.10 to 1.0) kΩ (1.0 to 10) kΩ 0.062 % + 0.058 Ω 0.058 % + 0.059 Ω 0.057 % + 0.59 Ω 0.12 % + 12 Ω Fluke 75x calibrator Electrical Calibration of Thermocouples – Measure Type B Type C Type E Type J Type K (600 to 1800) °C (0 to 2316) °C (-200 to 1000) °C (-100 to 1200) °C (-100 to 1372) °C 0.39 °C 0.39 °C 0.15 °C 0.14 °C 0.16 °C Fluke 7526A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1740.01) 06/18/2025 Page 3 of 7 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples – Measure (cont) Type N Type R Type S Type T (-100 to 1300) °C (100 to 1767) °C (100 to 1767) °C (-200 to 400) °C 0.15 °C 0.33 °C 0.34 °C 0.19 °C Fluke 7526A Electrical Calibration of Thermocouples – Measure3 Type B Type C Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1820) °C (0 to 800) °C (800 to 1200) °C (1200 to 1800) °C (1800 to 2316) °C (-200 to -100) °C (-100 to 600) °C (600 to 1000) °C (-100 to 800) °C (800 to 1200) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1372) °C (-100 to 900 °C (900 to 1300) °C (0 to 100) °C (100 to 1767) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-200 to 0) °C (0 to 400) °C 1.8 °C 1.4 °C 1.3 °C 0.97 °C 1.2 °C 1.6 °C 2.6 °C 0.85 °C 0.62 °C 0.72 °C 0.62 °C 0.84 °C 0.63 °C 0.84 °C 0.84 °C 0.84 °C 0.96 °C 2.0 °C 1.4 °C 2.0 °C 1.3 °C 1.5 °C 0.95 °C 0.62 °C Fluke 75x calibrator
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1740.01) 06/18/2025 Page 4 of 7 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators – Type B Type C Type E Type J Type K Type N Type R Type S Type T (600 to 1800) °C (0 to 2316) °C (-200 to 1000) °C (-100 to 1200) °C (-100 to 1372) °C (-100 to 1300) °C (100 to 1767) °C (100 to 1767) °C (-200 to 400) °C 0.39 °C 0.39 °C 0.15 °C 0.14 °C 0.16 °C 0.15 °C 0.33 °C 0.34 °C 0.19 °C Fluke 7526A Electrical Calibration of Thermocouple Indicators3 – Type B Type C Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1820) °C (0 to 800) °C (800 to 1200) °C (1200 to 1800) °C (1800 to 2316) °C (-200 to 600) °C (600 to 1000) °C (-100 to 800) °C (800 to 1200) °C (-100 to 1372) °C (-100 to 900) °C (900 to 1300) °C (0 to 100) °C (100 to 1767) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-200 to 0) °C (0 to 400) °C 1.4 °C 1.2 °C 0.96 °C 1.1 °C 1.3 °C 1.8 °C 0.62 °C 0.51 °C 0.51 °C 0.62 °C 0.62 °C 0.84 °C 0.62 °C 1.5 °C 1.3 °C 1.5 °C 1.3 °C 1.4 °C 0.73 °C 0.62 °C Fluke 75x calibrator
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1740.01) 06/18/2025 Page 5 of 7 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs – Measure 100 Ω, Pt (3916) 100 Ω, Pt (385) 100 Ω, Pt (3926) (-200 to 630) °C (-200 to 800) °C (-200 to 630) °C 0.033 °C 0.039 °C 0.033 °C Fluke 7526A Electrical Calibration of RTDs – Measure 3 100 Ω, Pt (3916) 100 Ω, Pt (385) 100 Ω, Pt (3926) (-200 to 100) °C (100 to 630) °C (-200 to 100) °C (100 to 800) °C (-200 to 100) °C (100 to 630) °C 0.083 °C 0.21 °C 0.083 °C 0.24 °C 0.094 °C 0.22 °C Fluke 75x calibrator Electrical Calibration of RTD Indicators – 100 Ω, Pt (3916) 100 Ω, Pt (385) 100 Ω, Pt (3926) (-200 to 630) °C (-200 to 800) °C (-200 to 630) °C 0.05 °C 0.05 °C 0.05 °C Fluke 7526A Electrical Calibration of RTD Indicators 3 – 100 Ω, Pt (3916) 100 Ω, Pt (385) 100 Ω, Pt (3926) (-200 to 100) °C (100 to 630) °C (-200 to 100) °C (100 to 800) °C (-200 to 100) °C (100 to 630) °C 0.06 °C 0.16 °C 0.06 °C 0.16 °C 0.06 °C 0.16 °C Fluke 75x calibrator
-200 to 800 °C
6AMS2750 and AIAG CQI-9, CQI-11, CQI-12-0 to 1200 °C
7AMS2750; AIAG CQI-9, CQI-11, CQI-12-See scope document
8ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.