What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 8 scope lines.
A2LA certificate 1740.01 · 8 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1740.01) 06/18/2025 Page 2 of 7
Parameter/Equipment
Range CMC2, 4 (±) Comments
DC Current – Generate3
Source
Simulate
(0 to 22) mA
(0 to 22) mA
0.013 % + 4 µA
0.024 % + 81 µA
Fluke 75x calibrator
DC Current – Measure
(0 to 50) mA
0.01 % + 0.001 mA
Fluke 7526A
DC Current – Measure3
(0 to 30) mA
(30 to 100) mA
0.013 % + 6 µA
0.012 % + 27 µA
Fluke 75x calibrator
Resistance – Generate
(5 to 400) Ω
(400 to 4000) Ω
0.015 Ω
0.3 Ω
Fluke 7526A
Resistance – Generate3
(0 to 10) Ω
(10 to 100) Ω
(0.10 to 1.0) kΩ
(1.0 to 10) kΩ
0.012 % + 0.012 Ω
0.011 % + 0.024 Ω
0.023 % + 0.24 Ω
0.023 % + 3.5 Ω
Fluke 75x calibrator
Resistance – Generate3
(20 to 1121) Ω
0.023 % + 0.13 mΩ
General resistance
decade box
Resistance – Measure
(0 to 400) Ω
(400 to 4000) Ω
0.0021 % + 0.004 Ω
0.0021 % + 0.04 Ω
Fluke 7526A
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.10 to 1.0) kΩ
(1.0 to 10) kΩ
0.062 % + 0.058 Ω
0.058 % + 0.059 Ω
0.057 % + 0.59 Ω
0.12 % + 12 Ω
Fluke 75x calibrator
Electrical Calibration of
Thermocouples – Measure
Type B
Type C
Type E
Type J
Type K
(600 to 1800) °C
(0 to 2316) °C
(-200 to 1000) °C
(-100 to 1200) °C
(-100 to 1372) °C
0.39 °C
0.39 °C
0.15 °C
0.14 °C
0.16 °C
Fluke 7526A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1740.01) 06/18/2025 Page 3 of 7
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouples – Measure
(cont)
Type N
Type R
Type S
Type T
(-100 to 1300) °C
(100 to 1767) °C
(100 to 1767) °C
(-200 to 400) °C
0.15 °C
0.33 °C
0.34 °C
0.19 °C
Fluke 7526A
Electrical Calibration of
Thermocouples – Measure3
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1820) °C
(0 to 800)
°C
(800 to 1200) °C
(1200 to 1800) °C
(1800 to 2316) °C
(-200 to -100) °C
(-100 to 600) °C
(600 to 1000) °C
(-100 to 800)
°C
(800 to 1200) °C
(-100 to 400)
°C
(400 to 1200) °C
(1200 to 1372) °C
(-100 to 900 °C
(900 to 1300) °C
(0 to 100) °C
(100 to 1767) °C
(0 to 200) °C
(200 to 1400) °C
(1400 to 1767) °C
(-200 to 0) °C
(0 to 400) °C
1.8 °C
1.4 °C
1.3 °C
0.97 °C
1.2 °C
1.6 °C
2.6 °C
0.85 °C
0.62 °C
0.72 °C
0.62 °C
0.84 °C
0.63 °C
0.84 °C
0.84 °C
0.84 °C
0.96 °C
2.0 °C
1.4 °C
2.0 °C
1.3 °C
1.5 °C
0.95 °C
0.62 °C
Fluke 75x calibrator | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1740.01) 06/18/2025 Page 4 of 7
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicators –
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 1800) °C
(0 to 2316) °C
(-200 to 1000) °C
(-100 to 1200) °C
(-100 to 1372) °C
(-100 to 1300) °C
(100 to 1767) °C
(100 to 1767) °C
(-200 to 400) °C
0.39 °C
0.39 °C
0.15 °C
0.14 °C
0.16 °C
0.15 °C
0.33 °C
0.34 °C
0.19 °C
Fluke 7526A
Electrical Calibration of
Thermocouple Indicators3 –
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1820) °C
(0 to 800) °C
(800 to 1200) °C
(1200 to 1800) °C
(1800 to 2316) °C
(-200 to 600) °C
(600 to 1000) °C
(-100 to 800)
°C
(800 to 1200) °C
(-100 to 1372)
°C
(-100 to 900) °C
(900 to 1300) °C
(0 to 100) °C
(100 to 1767) °C
(0 to 200)
°C
(200 to 1400) °C
(1400 to 1767) °C
(-200 to 0) °C
(0 to 400) °C
1.4 °C
1.2 °C
0.96 °C
1.1 °C
1.3 °C
1.8 °C
0.62 °C
0.51 °C
0.51 °C
0.62 °C
0.62 °C
0.84 °C
0.62 °C
1.5 °C
1.3 °C
1.5 °C
1.3 °C
1.4 °C
0.73 °C
0.62 °C
Fluke 75x calibrator | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1740.01) 06/18/2025 Page 5 of 7
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
RTDs – Measure
100 Ω, Pt (3916)
100 Ω, Pt (385)
100 Ω, Pt (3926)
(-200 to 630) °C
(-200 to 800) °C
(-200 to 630) °C
0.033 °C
0.039 °C
0.033 °C
Fluke 7526A
Electrical Calibration of
RTDs – Measure
3
100 Ω, Pt (3916)
100 Ω, Pt (385)
100 Ω, Pt (3926)
(-200 to 100) °C
(100 to 630) °C
(-200 to 100)
°C
(100 to 800) °C
(-200 to 100)
°C
(100 to 630) °C
0.083 °C
0.21 °C
0.083 °C
0.24 °C
0.094 °C
0.22 °C
Fluke 75x calibrator
Electrical Calibration of
RTD Indicators –
100 Ω, Pt (3916)
100 Ω, Pt (385)
100 Ω, Pt (3926)
(-200 to 630) °C
(-200 to 800) °C
(-200 to 630) °C
0.05 °C
0.05 °C
0.05 °C
Fluke 7526A
Electrical Calibration of
RTD Indicators
3 –
100 Ω, Pt (3916)
100 Ω, Pt (385)
100 Ω, Pt (3926)
(-200 to 100) °C
(100 to 630) °C
(-200 to 100) °C
(100 to 800) °C
(-200 to 100) °C
(100 to 630) °C
0.06 °C
0.16 °C
0.06 °C
0.16 °C
0.06 °C
0.16 °C
Fluke 75x calibrator | -200 to 800 °C |
| 6 | AMS2750 and AIAG CQI-9, CQI-11, CQI-12 | - | 0 to 1200 °C |
| 7 | AMS2750; AIAG CQI-9, CQI-11, CQI-12 | - | See scope document |
| 8 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aldinger Company DBA Quality Control ServicesMilwaukie, ORA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.