What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 3908.01 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 6 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 2 of 11
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage – Generate3
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
22 μV/V + 1 μV
10 μV/V + 2 μV
9.7 μV/V + 20 μV
18 μV/V + 150 μV
14 μV/V + 1500 μV
Fluke 5520A/SC600
DC Voltage – Measure3
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 10) kV
15 μV/V + 0.3 μV
12 μV/V + 0.3 μV
9.4 μV/V + 0.5 μV
16 μV/V + 30 μV
15 μV/V + 100 μV
0.12 %
Agilent 3458A
Vitrek 4700
DC Current – Generate3
Clamp-On Only
Non-Toroidal Type
Clamp
(0 to 330) μA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(16.5 to 150) A
(150 to 550) A
(550 to 1025) A
0.012 % + 0.02 µA
0.0084 % + 0.05 µA
0.0084 % + 0.25 µA
0.011 % + 2.5 µA
0.016 % + 40 µA
0.030 % + 40 µA
0.051 % + 500 µA
0.10 % + 750 µA
1.5 %
0.97 %
0.72 %
Fluke 5520A/SC600
Fluke 5520A with
5500A coil
DC Current – Measure3
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(3 to 20) A
40 μA/A + 0.8 nA
38 μA/A + 5 nA
37 μA/A + 50 nA
79 μA/A + 0.5 µA
0.015 % + 10 µA
0.17 % + 0.6 mA
0.029 %
Agilent 3458A
Agilent 34410A
Current shunts w/
Agilent 3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 3 of 11
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
92 μΩ/Ω + 1.0 mΩ
48 μΩ/Ω + 1.5 mΩ
27 μΩ/Ω + 1.4 mΩ
23 μΩ/Ω + 2.0 mΩ
22 μΩ/Ω + 2.0 mΩ
23 μΩ/Ω + 0.02 Ω
23 μΩ/Ω + 0.02 Ω
23 μΩ/Ω + 0.2 Ω
23 μΩ/Ω + 0.2 Ω
26 μΩ/Ω + 2.0 Ω
26 μΩ/Ω + 2.0 Ω
51 μΩ/Ω + 30 Ω
0.012 % + 50 Ω
0.034 % + 2.5 kΩ
0.040 % + 3.0 kΩ
0.23 % + 0.10 MΩ
1.2 % + 0.50 MΩ
Fluke 5520A/SC600
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
38 μΩ/Ω + 0.05 mΩ
21 μΩ/Ω + 0.5 mΩ
13 μΩ/Ω + 0.5 mΩ
12 μΩ/Ω + 5.0 mΩ
12 μΩ/Ω + 50 mΩ
20 μΩ/Ω + 2 Ω
68 μΩ/Ω + 100 Ω
0.061 % + 1.0 kΩ
Agilent 3458A
Electrical Calibration
of Thermocouple
Indicators – Generate &
Measure3
Type E
Type J
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 600) °C
(600 to 1000) °C
(-210 to 100) °C
(-100 to 800) °C
(800 to 1200) °C
0.72 °C
0.15 °C
0.12 °C
0.11 °C
0.13 °C
0.17 °C
0.12 °C
0.13 °C
Fluke 7526A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 4 of 11
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration
of Thermocouple
Indicators – Generate &
Measure3 (cont)
Type K
Type N
Type S
Type T
(-250 to -200) °C
(-200 to -100) °C
(-100 to 500) °C
(500 to 800) °C
(800 to 1372) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 100) °C
(100 to 800) °C
(800 to 1300) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 200) °C
(200 to 400) °C
0.53 °C
0.19 °C
0.13 °C
0.13 °C
0.16 °C
0.84 °C
0.27 °C
0.15 °C
0.14 °C
0.13 °C
0.15 °C
0.62 °C
0.54 °C
0.48 °C
0.36 °C
0.29 °C
0.28 °C
0.28 °C
0.32 °C
0.40 °C
0.19 °C
0.14 °C
0.12 °C
0.12 °C
Fluke 7526A | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 5 of 11
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Electrical Calibration
of RTD Indicators3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to 800) °C
(-200 to 630) °C
(-200 to 630) °C
(-200 to 400) °C
(400 to 630) °C
(-200 to 630) °C
(-200 to 630) °C
(-80 to 260) °C
(-100 to 260) °C
0.10 °C
0.084 °C
0.079 °C
0.45 °C
0.57 °C
0.21 °C
0.11 °C
0.039 °C
0.63 °C
Fluke 7526A
Oscilloscope3 –
Amplitude – DC Signal
50 Ω Load
1 MΩ Load
Square Wave Signal
50 Ω Load @1kHz
Source
1 MΩ Load @1kHz
Source
Level Sine Wave
Amplitude (50 kHz
Reference)
Flatness
(50 kHz Reference)
1 mV to 6.599 V
1 mV to 130 V
1 mV to 6.599 V
1 mV to 130 V
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
0.32 %
+ 40 µV
0.089 % + 40 µV
0.27 % + 40 µV
0.38 % + 40 µV
2.5 % + 300 µV
4.2 % + 300 µV
5.0 % + 300 µV
6.9 % + 300 µV
2.4 % + 100 µV
2.9 % + 100 µV
4.7 % + 100 µV
Fluke 5520A/SC600 | -200 to 800 °C |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 6 of 11
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Oscilloscope3 (cont.) –
Time Markers:
Source & Period
Into a 50 Ω Load
5 s to 50 ms
20 ms to 2 ns
(31 + 1000t) parts in 10
6 s
2.9 parts in 106 s
Fluke 5520A/SC600
t is the time in
seconds
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(0 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.096 % + 6 µV
0.035 % + 6 µV
0.037 % + 6 µV
0.10 % + 6 µV
0.28 % + 12 µV
0.66 % + 50 µV
0.059 % + 8 µV
0.015 % + 8 µV
0.016 % + 8 µV
0.031 % + 8 µV
0.067 % + 32 µV
0.17 % + 70 µV
0.028 % + 50 µV
0.012 % + 60 µV
0.015 % + 60 µV
0.023 % + 50 µV
0.054 % + 130 µV
0.19 % + 600 µV
0.028 % + 650 µV
0.018 % + 600 µV
0.022 % + 600 µV
0.029 % + 600 µV
0.069 % + 1.6 mV
0.015 % + 2 mV
0.017 % + 6 mV
0.021 % + 6 mV
0.027 % + 6 mV
0.15 % + 50 mV
0.024 % + 10 mV
0.020 % + 10 mV
0.024 % + 10 mV
Fluke 5520A/SC600 | to 1020 V |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 7 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
10 mV
100 mV
1 V
10 V
100 V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.10 % + 1.1 µV
0.11 % + 1.1 µV
0.16 % + 1.1 µV
0.58 % + 1.1 µV
4.6 % + 2 µV
1.4 % + 5 µV
8.5 % + 7 µV
0.012 % + 2 µV
0.018 % + 2 µV
0.052 % + 2 µV
0.099 % + 2 µV
0.34 % + 10 µV
1.1 % + 10 µV
1.6 % + 10 µV
4.6 % + 70 µV
4.8 % + 80 µV
19 % + 100 µV
0.011 % + 20 µV
0.018 % + 20 µV
0.035 % + 20 µV
0.093 % + 20 µV
0.34 % + 0.10 mV
1.1 % + 0.10 mV
1.6 % + 0.10 mV
4.5 % + 0.70 mV
4.7 % + 0.80 mV
19 % + 1.0 mV
0.019 % + 0.40 mV
0.015 % + 0.20 mV
0.020 % + 0.20 mV
0.039 % + 0.20 mV
0.098 % + 0.20 mV
0.35 % + 1 mV
1.2 % + 1 mV
1.9 % + 1 mV
4.4 % + 7 mV
4.6 % + 8 mV
18 % + 10 mV
0.027 % + 2 mV
0.039 % + 2 mV
0.049 % + 2 mV
0.15 % + 2 mV
Agilent 3458A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 8 of 11
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Measure3
(cont)
1000 V
>750 V to 10 kV
40 Hz to 1 kHz
(1 to 20) kHz
60 Hz
0.059 % + 20 mV
0.088 % + 20 mV
0.29 %
Agilent 3458A
Vitrek 4700
AC Current – Generate3
(29 to 330) μA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.20 % + 0.1 µA
0.17 % + 0.1 µA
0.16 % + 0.1 µA
0.27 % + 0.15 µA
0.65 % + 0.2 µA
1.7 % + 0.4 µA
0.16 % + 0.15 µA
0.10 % + 0.15 µA
0.084 % + 0.15 µA
0.16 % + 0.2 µA
0.39 % + 0.3 µA
0.78 % + 0.6 µA
0.15 % + 2 µA
0.080 % + 2 µA
0.048 % + 2 µA
0.064 % + 2 µA
0.16 % + 3 µA
0.31 % + 4 µA
0.15 % + 20 µA
0.079 % + 20 µA
0.048 % + 20 µA
0.090 % + 50 µA
0.16 % + 100 µA
0.32 % + 200 µA
0.14 % + 0.1 mA
0.050 % + 0.1 mA
0.47 % + 1 mA
2.0 % + 5 mA
0.14 % + 0.1 mA
0.050 % + 0.1 mA
0.50 % + 1 mA
2.0 % + 5 mA
Fluke 5520A/SC600 | 750 to 10000 V |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 9 of 11
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Current – Generate3
(cont)
(3 to 11) A
(11 to 20.5) A
Clamp-On Only
Toroidal Type Clamp
(16.5 to 150) A
(150 to 1025) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal Type Clamp
(16.5 to 150) A
(150 to 1025) A
(550 to 1025) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(45 to 65) Hz
(65 to 440) Hz
(65 to 440) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
0.39 % + 2 mA
0.09 % + 2 mA
2.3 % + 2 mA
0.11 % + 5 mA
0.13 % + 5 mA
2.3 % + 5 mA
0.43 %
0.46 %
1.0 %
1.5 %
2.2 %
1.4 %
0.93 %
Fluke 5520A/SC600
Fluke 5520A with
5500A coil
AC Current – Measure3
(0 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1A
(1 to 3) A
(3 to 30) A
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
3 Hz to 5 kHz
45 Hz to 1 kHz
0.071 % + 0.03 µA
0.071 % + 0.03 µA
0.069 % + 0.2 µA
0.037 % + 0.2 µA
0.069 % + 2 µA
0.036 % + 2 µA
0.070 % + 20 µA
0.037 % + 20 µA
0.094 % + 0.2 mA
0.12 % + 0.2 mA
0.12 % + 1.2 mA
0.26 %
Agilent 3458A
Agilent 34410A
with current
transformer | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 10 of 11
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.9999) nF
(110 to 329.9999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.68 % + 0.01 nF
0.42 % + 0.01 nF
0.40 % + 0.01 nF
0.20 % + 0.01 nF
0.20 % + 0.1 nF
0.20 % + 0.1 nF
0.20 % + 0.3 nF
0.20 % + 1 nF
0.20 % + 3 nF
0.21 % + 10 nF
0.32 % + 30 nF
0.37 % + 100 nF
0.36 % + 300 nF
0.36 % + 1 µF
0.34 % + 3 µF
0.35 % + 10 µF
0.57 % + 30 µF
0.86 % + 100 µF
Fluke 5520A/SC600
III. Thermodynamics
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Timers/Stopwatches
1 s to 24 hr
0.40 s
HP 53132A
____________________________________________________________________ _________________________
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature –
Liquid-in-Glass
Thermometers &
Temperature Measuring
Devices3
(-20 to 120) °C
0.089 °C
Fluke 7526A with Fluke
5618B RTD probe in
temperature bath
Temperature –
Measure3
(-200 to 500) °C
0.13 °C
Fluke 7526A with Fluke
5618B RTD probe | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3908.01) 11/20/2025 Page 11 of 11
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the
laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
and R is the resolution of the unit under test, and percentages are percentages of reading unless otherwise
noted.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Test & MeasurementLenexa, KS · ~262 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Johnson Gage and InspectionWichita, KS · ~351 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ledford GageMulvane, KS · ~373 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - MinneapolisBloomington, MN · ~526 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- United StandardsBloomington, MN · ~526 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.