United States

Duncan Aviation

3701 Aviation Road, 68524, Lincoln, NE, United States

Visit website
A2LA 3908.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 3908.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 6 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 2 of 11 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage – Generate3 (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V 22 μV/V + 1 μV 10 μV/V + 2 μV 9.7 μV/V + 20 μV 18 μV/V + 150 μV 14 μV/V + 1500 μV Fluke 5520A/SC600 DC Voltage – Measure3 (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 10) kV 15 μV/V + 0.3 μV 12 μV/V + 0.3 μV 9.4 μV/V + 0.5 μV 16 μV/V + 30 μV 15 μV/V + 100 μV 0.12 % Agilent 3458A Vitrek 4700 DC Current – Generate3 Clamp-On Only Non-Toroidal Type Clamp (0 to 330) μA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (16.5 to 150) A (150 to 550) A (550 to 1025) A 0.012 % + 0.02 µA 0.0084 % + 0.05 µA 0.0084 % + 0.25 µA 0.011 % + 2.5 µA 0.016 % + 40 µA 0.030 % + 40 µA 0.051 % + 500 µA 0.10 % + 750 µA 1.5 % 0.97 % 0.72 % Fluke 5520A/SC600 Fluke 5520A with 5500A coil DC Current – Measure3 (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 3) A (3 to 20) A 40 μA/A + 0.8 nA 38 μA/A + 5 nA 37 μA/A + 50 nA 79 μA/A + 0.5 µA 0.015 % + 10 µA 0.17 % + 0.6 mA 0.029 % Agilent 3458A Agilent 34410A Current shunts w/ Agilent 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 3 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 92 μΩ/Ω + 1.0 mΩ 48 μΩ/Ω + 1.5 mΩ 27 μΩ/Ω + 1.4 mΩ 23 μΩ/Ω + 2.0 mΩ 22 μΩ/Ω + 2.0 mΩ 23 μΩ/Ω + 0.02 Ω 23 μΩ/Ω + 0.02 Ω 23 μΩ/Ω + 0.2 Ω 23 μΩ/Ω + 0.2 Ω 26 μΩ/Ω + 2.0 Ω 26 μΩ/Ω + 2.0 Ω 51 μΩ/Ω + 30 Ω 0.012 % + 50 Ω 0.034 % + 2.5 kΩ 0.040 % + 3.0 kΩ 0.23 % + 0.10 MΩ 1.2 % + 0.50 MΩ Fluke 5520A/SC600 Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 38 μΩ/Ω + 0.05 mΩ 21 μΩ/Ω + 0.5 mΩ 13 μΩ/Ω + 0.5 mΩ 12 μΩ/Ω + 5.0 mΩ 12 μΩ/Ω + 50 mΩ 20 μΩ/Ω + 2 Ω 68 μΩ/Ω + 100 Ω 0.061 % + 1.0 kΩ Agilent 3458A Electrical Calibration of Thermocouple Indicators – Generate & Measure3 Type E Type J (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C (-210 to 100) °C (-100 to 800) °C (800 to 1200) °C 0.72 °C 0.15 °C 0.12 °C 0.11 °C 0.13 °C 0.17 °C 0.12 °C 0.13 °C Fluke 7526A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 4 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicators – Generate & Measure3 (cont) Type K Type N Type S Type T (-250 to -200) °C (-200 to -100) °C (-100 to 500) °C (500 to 800) °C (800 to 1372) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 200) °C (200 to 400) °C 0.53 °C 0.19 °C 0.13 °C 0.13 °C 0.16 °C 0.84 °C 0.27 °C 0.15 °C 0.14 °C 0.13 °C 0.15 °C 0.62 °C 0.54 °C 0.48 °C 0.36 °C 0.29 °C 0.28 °C 0.28 °C 0.32 °C 0.40 °C 0.19 °C 0.14 °C 0.12 °C 0.12 °C Fluke 7526A
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 5 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Calibration of RTD Indicators3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω Cu 427, 10 Ω (-200 to 800) °C (-200 to 630) °C (-200 to 630) °C (-200 to 400) °C (400 to 630) °C (-200 to 630) °C (-200 to 630) °C (-80 to 260) °C (-100 to 260) °C 0.10 °C 0.084 °C 0.079 °C 0.45 °C 0.57 °C 0.21 °C 0.11 °C 0.039 °C 0.63 °C Fluke 7526A Oscilloscope3 – Amplitude – DC Signal 50 Ω Load 1 MΩ Load Square Wave Signal 50 Ω Load @1kHz Source 1 MΩ Load @1kHz Source Level Sine Wave Amplitude (50 kHz Reference) Flatness (50 kHz Reference) 1 mV to 6.599 V 1 mV to 130 V 1 mV to 6.599 V 1 mV to 130 V 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 0.32 % + 40 µV 0.089 % + 40 µV 0.27 % + 40 µV 0.38 % + 40 µV 2.5 % + 300 µV 4.2 % + 300 µV 5.0 % + 300 µV 6.9 % + 300 µV 2.4 % + 100 µV 2.9 % + 100 µV 4.7 % + 100 µV Fluke 5520A/SC600
-200 to 800 °C
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 6 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Oscilloscope3 (cont.) – Time Markers: Source & Period Into a 50 Ω Load 5 s to 50 ms 20 ms to 2 ns (31 + 1000t) parts in 10 6 s 2.9 parts in 106 s Fluke 5520A/SC600 t is the time in seconds Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (0 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.096 % + 6 µV 0.035 % + 6 µV 0.037 % + 6 µV 0.10 % + 6 µV 0.28 % + 12 µV 0.66 % + 50 µV 0.059 % + 8 µV 0.015 % + 8 µV 0.016 % + 8 µV 0.031 % + 8 µV 0.067 % + 32 µV 0.17 % + 70 µV 0.028 % + 50 µV 0.012 % + 60 µV 0.015 % + 60 µV 0.023 % + 50 µV 0.054 % + 130 µV 0.19 % + 600 µV 0.028 % + 650 µV 0.018 % + 600 µV 0.022 % + 600 µV 0.029 % + 600 µV 0.069 % + 1.6 mV 0.015 % + 2 mV 0.017 % + 6 mV 0.021 % + 6 mV 0.027 % + 6 mV 0.15 % + 50 mV 0.024 % + 10 mV 0.020 % + 10 mV 0.024 % + 10 mV Fluke 5520A/SC600
to 1020 V
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 7 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 10 mV 100 mV 1 V 10 V 100 V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.10 % + 1.1 µV 0.11 % + 1.1 µV 0.16 % + 1.1 µV 0.58 % + 1.1 µV 4.6 % + 2 µV 1.4 % + 5 µV 8.5 % + 7 µV 0.012 % + 2 µV 0.018 % + 2 µV 0.052 % + 2 µV 0.099 % + 2 µV 0.34 % + 10 µV 1.1 % + 10 µV 1.6 % + 10 µV 4.6 % + 70 µV 4.8 % + 80 µV 19 % + 100 µV 0.011 % + 20 µV 0.018 % + 20 µV 0.035 % + 20 µV 0.093 % + 20 µV 0.34 % + 0.10 mV 1.1 % + 0.10 mV 1.6 % + 0.10 mV 4.5 % + 0.70 mV 4.7 % + 0.80 mV 19 % + 1.0 mV 0.019 % + 0.40 mV 0.015 % + 0.20 mV 0.020 % + 0.20 mV 0.039 % + 0.20 mV 0.098 % + 0.20 mV 0.35 % + 1 mV 1.2 % + 1 mV 1.9 % + 1 mV 4.4 % + 7 mV 4.6 % + 8 mV 18 % + 10 mV 0.027 % + 2 mV 0.039 % + 2 mV 0.049 % + 2 mV 0.15 % + 2 mV Agilent 3458A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 8 of 11 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage – Measure3 (cont) 1000 V >750 V to 10 kV 40 Hz to 1 kHz (1 to 20) kHz 60 Hz 0.059 % + 20 mV 0.088 % + 20 mV 0.29 % Agilent 3458A Vitrek 4700 AC Current – Generate3 (29 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.20 % + 0.1 µA 0.17 % + 0.1 µA 0.16 % + 0.1 µA 0.27 % + 0.15 µA 0.65 % + 0.2 µA 1.7 % + 0.4 µA 0.16 % + 0.15 µA 0.10 % + 0.15 µA 0.084 % + 0.15 µA 0.16 % + 0.2 µA 0.39 % + 0.3 µA 0.78 % + 0.6 µA 0.15 % + 2 µA 0.080 % + 2 µA 0.048 % + 2 µA 0.064 % + 2 µA 0.16 % + 3 µA 0.31 % + 4 µA 0.15 % + 20 µA 0.079 % + 20 µA 0.048 % + 20 µA 0.090 % + 50 µA 0.16 % + 100 µA 0.32 % + 200 µA 0.14 % + 0.1 mA 0.050 % + 0.1 mA 0.47 % + 1 mA 2.0 % + 5 mA 0.14 % + 0.1 mA 0.050 % + 0.1 mA 0.50 % + 1 mA 2.0 % + 5 mA Fluke 5520A/SC600
750 to 10000 V
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 9 of 11 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Current – Generate3 (cont) (3 to 11) A (11 to 20.5) A Clamp-On Only Toroidal Type Clamp (16.5 to 150) A (150 to 1025) A (16.5 to 150) A (150 to 1025) A Non-Toroidal Type Clamp (16.5 to 150) A (150 to 1025) A (550 to 1025) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz 0.39 % + 2 mA 0.09 % + 2 mA 2.3 % + 2 mA 0.11 % + 5 mA 0.13 % + 5 mA 2.3 % + 5 mA 0.43 % 0.46 % 1.0 % 1.5 % 2.2 % 1.4 % 0.93 % Fluke 5520A/SC600 Fluke 5520A with 5500A coil AC Current – Measure3 (0 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1A (1 to 3) A (3 to 30) A (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz 3 Hz to 5 kHz 45 Hz to 1 kHz 0.071 % + 0.03 µA 0.071 % + 0.03 µA 0.069 % + 0.2 µA 0.037 % + 0.2 µA 0.069 % + 2 µA 0.036 % + 2 µA 0.070 % + 20 µA 0.037 % + 20 µA 0.094 % + 0.2 mA 0.12 % + 0.2 mA 0.12 % + 1.2 mA 0.26 % Agilent 3458A Agilent 34410A with current transformer
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 10 of 11 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.9999) nF (110 to 329.9999) nF (0.33 to 1.099 99) μF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.999) μF (110 to 329.999) μF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.68 % + 0.01 nF 0.42 % + 0.01 nF 0.40 % + 0.01 nF 0.20 % + 0.01 nF 0.20 % + 0.1 nF 0.20 % + 0.1 nF 0.20 % + 0.3 nF 0.20 % + 1 nF 0.20 % + 3 nF 0.21 % + 10 nF 0.32 % + 30 nF 0.37 % + 100 nF 0.36 % + 300 nF 0.36 % + 1 µF 0.34 % + 3 µF 0.35 % + 10 µF 0.57 % + 30 µF 0.86 % + 100 µF Fluke 5520A/SC600 III. Thermodynamics IV. Time & Frequency Parameter/Equipment Range CMC2, 5, 6 (±) Comments Timers/Stopwatches 1 s to 24 hr 0.40 s HP 53132A ____________________________________________________________________ _________________________ Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Liquid-in-Glass Thermometers & Temperature Measuring Devices3 (-20 to 120) °C 0.089 °C Fluke 7526A with Fluke 5618B RTD probe in temperature bath Temperature – Measure3 (-200 to 500) °C 0.13 °C Fluke 7526A with Fluke 5618B RTD probe
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3908.01) 11/20/2025 Page 11 of 11 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, and R is the resolution of the unit under test, and percentages are percentages of reading unless otherwise noted. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.