FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

PVSR Corporation dba ProvenSmart

Bayamon, United States

A2LA|7474.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
0
Locations
2
One of 2 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at PVSR Corporation dba ProvenSmart?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
7474.01Active

Accredited standards

We found no published test standard numbers in this lab’s scope (labs often list in-house methods instead). The full scope as published is below.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

7474.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 7474.01

This scope has not been split into individual lines yet. Below is the text of the scope document as published.

Part 1 of 4

(A2LA Cert. No. 7474.01) Revised 03/25/2026 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 SSA PR ACQUISITION HOLDCO LLC DBA PROVEN SMART Street E, Lot 80/81 Lot 80/81, Int. Road PR-174, Km 3.0 Minillas Industrial Park Bayamón, Puerto Rico 00959 Angel Pabellon Phone: (787) 807-7877 CALIBRATION Valid To: March 31, 2027 Certificate Number: 7474.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Pressure – Measuring Equipment Pneumatic (Air) (3 to 50) psi (> 50 to 500) psi 0.005 psi 0.01 % Deadweight tester II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature – Measuring Equipment (PRT/RTD Sensors, TC Sensors, Thermistor Sensor, Digital Thermometers, Mechanical Thermometer) -195 °C (-80 to -40) °C (-40 to -20) °C 0.0 °C (0.0 to 100) °C (100 to 232) °C (232 to 420) °C (420 to 660) °C 0.006 °C 0.009 °C 0.009 °C 0.008 °C 0.009 °C 0.010 °C 0.019 °C 0.021 °C SPRT, black stack, bath

Part 2 of 4

(A2LA Cert. No. 7474.01) Revised 03/25/2026 Page 2 of 3 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature – Environmental Measuring Equipment (5 to 70) °C 0.08 °C Thunder Scientific 2500 humidity generator Temperature – Measure Portable Liquid Baths, Dry Wells, Incubators, Freezers, Furnaces, Refrigerators or Portable Chambers3 (-195 to -80) °C (-80 to 0) °C (0.0 to 30) °C (30 to 157) °C (157 to 232) °C (232 to 420) °C 0.05 °C 0.06 °C 0.07 °C 0.09 °C 0.10 °C 0.14 °C PRT probe, temperature readout, bath Temperature – Measuring Equipment (LIG Thermometers) (-20 to 150) °C 0.58 °C Comparison with SPRT/PRT and temperature readout Relative Humidity – Measuring Equipment (Humidity Meters, Chart Recorder, Transmitters) (10 to 95) % RH @23 °C 0.51 % RH Thunder Scientific 2500 Relative Humidity – Measure3 (11 to 95) % RH > 95 % RH 1.1 % RH 1.7 % RH Humidity standard III. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches & Timers (0 to 86 400) s/day 0.051 s Timometer 4500 ______________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.

Part 3 of 4

(A2LA Cert. No. 7474.01) Revised 03/25/2026 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentage refers to percent of reading, unless otherwise noted. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.

Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.