United States

PVSR Corporation dba ProvenSmart

Bayamon, United States

Visit website
A2LA 7474.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 7474.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7474.01) Revised 03/25/2026 Page 2 of 3 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature – Environmental Measuring Equipment (5 to 70) °C 0.08 °C Thunder Scientific 2500 humidity generator Temperature – Measure Portable Liquid Baths, Dry Wells, Incubators, Freezers, Furnaces, Refrigerators or Portable Chambers3 (-195 to -80) °C (-80 to 0) °C (0.0 to 30) °C (30 to 157) °C (157 to 232) °C (232 to 420) °C 0.05 °C 0.06 °C 0.07 °C 0.09 °C 0.10 °C 0.14 °C PRT probe, temperature readout, bath Temperature – Measuring Equipment (LIG Thermometers) (-20 to 150) °C 0.58 °C Comparison with SPRT/PRT and temperature readout Relative Humidity – Measuring Equipment (Humidity Meters, Chart Recorder, Transmitters) (10 to 95) % RH @23 °C 0.51 % RH Thunder Scientific 2500 Relative Humidity – Measure3 (11 to 95) % RH > 95 % RH 1.1 % RH 1.7 % RH Humidity standard III. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches & Timers (0 to 86 400) s/day 0.051 s Timometer 4500 ______________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7474.01) Revised 03/25/2026 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentage refers to percent of reading, unless otherwise noted. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.