Pfeiffer Vacuum

4037 Guion Lane, 46268, Indianapolis, IN, United States

Visit website
A2LA 2197.01A2LA 2197.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
6
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E498
ASTM E499
ASTM E515
ASTM F2391
ASTM F3287
USP 1207

Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

2197.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 2197.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2-gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2197.01) 04/01/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Gas Flow – Volume Flow Rate (12.5 to 4166) l/min (0.025 to 100) l/min (8.33 to 42) l/min (0.83 to 21) l/min (0.083 to 2.5) l/min 0.31 % of reading 0.26 % of reading 0.33 % of reading 0.41 % of reading 0.68 % of reading Gas flow primary standards. Gas flow reference temperature and pressure: (20 to 24) °C and (99 to 101.4) kPa. III. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pneumatic Absolute Pressure – Pressure Transducers Up to 100 psia Up to 500 psia 4 inꞏH2O to 10 psia 0.013 psia 0.065 psia 0.0012 psia or 0.03 % of reading (whichever is greater) Pressure standards Vacuum – Vacuum Transducers Up to 20 Torr 0.05 Torr or 0.6 % of reading (whichever is greater) Vacuum standard IV. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Thermometers, Temperature Probes (0 to 100) °C 0.2 °C Comparison with thermistor probe and readout ________________________________ 1 This laboratory offers commercial calibration service.
-
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2197.01) 04/01/2025 Page 3 of 3 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The contributions from the “best existing device” are not included in the CMC claim.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

2197.02

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 2197.02

LineMethodMatrixRange
1ISO/IEC 17025:2017; ASTM E498/E498M; ASTM E499/E499M; ASTM E515; ATC04-9-2-4; ASTM F3287; SAE J2587; SAE J2045; SAE J2973; ATC04-9-2-5; ASTM F2391; USP 1207Medical devices-
2

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Nondestructive Scope of Accreditation. Accredited Laboratory A2LA has accredited PFEIFFER VACUUM INC. Indianapolis, IN for technical competence in the field of Nondestructive Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of April 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2197.02 Valid to March 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4037 Guion Lane, Indianapolis, IN, 46268, US

39.76833, -86.15835