Ohm-Labs
611 E. Carson Street, 15203-1021, Pittsburgh, PA, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 2481.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 100 to 1000000 |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 2 of 4
Parameter/Equipment
Range3
CMC2, 6 (±)
Comments
Resistance – Measure
(cont)
(1 to <10) Ω
(10 to <100) Ω
(100 to <1000) Ω
(1 to 10) kΩ
(>10 to 100) kΩ
(>0.1 to 1) MΩ
(>1 to 10) MΩ
(>10 to 100) MΩ
(>100 to 1000) MΩ
(>1 to 10) GΩ
(>10 to 100) GΩ
(>100 to 1000) GΩ
(>1 to 10) TΩ
(0 to 10) Ω
(>10 to 100) Ω
(>100 to 1000) Ω
(>1 to 10) kΩ
(>10 to 100) kΩ
(>100 to 1000) kΩ
(>1 to 10) MΩ
(>10 to 100) MΩ
0.12 μΩ/Ω
0.15 μΩ/Ω
0.15 μΩ/Ω
0.12 μΩ/Ω
0.30 μΩ/Ω
1.8 μΩ/Ω
3.5 μΩ/Ω
6.0 µΩ/Ω
11 µΩ/Ω
20 µΩ/Ω
50 µΩ/Ω
0.010 % of rdg
0.020 % of rdg
35 µΩ/Ω + 0.06 mΩ
20 µΩ/Ω + 0.6 mΩ
15 µΩ/Ω + 0.6 mΩ
15 µΩ/Ω + 6 mΩ
20 µΩ/Ω + 60 mΩ
25 µΩ/Ω + 3 Ω
70 µΩ/Ω + 120 Ω
600 µΩ/Ω + 1200 Ω
MI 6242D bridge
Comparison with
guarded dual source
bridge
Measurement with
Agilent 3458A DMM
AC Voltage –
Measure, (50 & 60) Hz
(0 to 10) V
(>10 to 100) V
(>100 to 500) V
0.020 % of rdg + 0.20 mV
0.030 % of rdg + 2.0 mV
0.050 % of rdg + 22 mV
Agilent 3458A DMM
AC Voltage – Measure,
(50 & 60) Hz
(0.5 to 1.0) kV
(>1.0 to 10) kV
(>10 to 80) kV
(>80 to 100) kV
0.030 % of rdg + 0.050 V
0.030 % of rdg + 0.50 V
0.030 % of rdg + 5.0 V
0.040 % of rdg + 4.0 V
Agilent 3458A DMM
& MI 2500A divider
Agilent 3458A DMM
& Ohm-Lab’s HVT
divider
AC High Voltage
Ratio – Applied Voltage –
Measure
(100 to 100 000):1
(0.1 to 100) kV @
(50 or 60) Hz
0.050 % of ratio
Agilent 3458A
DMMs, MI 2500A
divider, Ohm-Labs
HVT divider | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 3 of 4
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC – DC Difference –
Measure
(2 to 10) mA
(>10 to 100) mA
(>0.1 to 1.0) A
(>1.0 to 2) A
(>2 to 20) A
(>20 to 50) A
(>50 to 100) A
(0.2 to 1.0) V
(>1 to 10) V
(>10 to 50) V
(>50 to 200) V
(>200 to 500) V
10 Hz to 50 kHz
>50 kHz to 1 MHz
10 Hz to 100 kHz
10 Hz to 100 kHz
(10 to 20) Hz
>20 Hz to 100 kHz
(10 to 20) Hz
>20 Hz to 50 kHz
(>50 to 100) kHz
10 Hz to 30 kHz
(>30 to 50) kHz
(>50 to 70) kHz
(>70 to 100) kHz
10 Hz to 50 kHz
(>50 to 70) kHz
(>70 to 100) kHz
10 Hz to 50 kHz
>50 kHz to 1 MHz
10 Hz to 100 kHz
>100 kHz to 1 MHz
10 Hz to 100 kHz
>100 kHz to 1 MHz
(10 to 100) Hz
(>0.01 to 100) kHz
(10 to 100) Hz
(>0.01 to 100) kHz
11 μA/A
16 μA/A
11 μA/A
15 μA/A
18 μA/A
15 μA/A
22 μA/A
28 μA/A
34 μA/A
28 μA/A
33 μA/A
37 μA/A
42 μA/A
45 μA/A
65 μA/A
85 μA/A
11 μV/V
16 μV/V
12 μV/V
22 μV/V
15 μV/V
30 μV/V
18 μV/V
15 μV/V
28 μV/V
22 μV/V
Comparison with
thermal voltage
converter
Comparison with
coaxial AC current
shunts using thermal
voltage converters
Comparison with
thermal voltage
converter
Comparison with
coaxial AC resistors
using thermal
voltage converters | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 4 of 4
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature –
Measure
(18 to 30) °C
(0 to 200) °C
0.020 °C
0.20 °C
Measurement with
Fluke 1504
thermometer
Measurement with
Isotech MilliK
thermometer
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Where ranges are not specified, the CMC stated is for the cardinal points only.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Process InstrumentsPittsburgh, PA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsAliquippa, PA · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation Powerlabs - Madison, PAMadison, PA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- JM Test SystemsMt. Braddock, PA · ~63 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~100 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.