Huston-DePue Calibration
Oklahoma City, OK, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 4167.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4167.01) 05/30/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Voltage – Measure
100 mV
1 V
10 V
100 V
1000 V
0.0036 % + 1 μV
0.0015 % + 1 μV
0.0016 % + 15 μV
0.0036 % + 1.5 mV
0.0023 % + 1.5 mV
Agilent 34401A
DC Current – Measure
10 mA
100 mA
1 A
3 A
0.014 % + 0.2 μA
0.013 % + 1 μA
0.028 % + 40 μA
0.044 % + 40 μA
Agilent 34401A
DC Current – Generate
(0 to 3.299 99) mA
(0 to 32.9999) mA
(0 to 329.999) mA
(0 to 2.199 99) A
(0 to 11) A
0.011 % + 0.05 μA
0.0083 % + 0.25 μA
0.0086 % + 3.3 μA
0.025 % + 44 μA
0.049 % + 330 μA
Fluke 5500A/
SC600
Resistance – Generate
(0 to 10.99) Ω
(11 to 32.999) Ω
(33 to 109.999) Ω
(110 to 329.999) Ω
330 Ω to 1.0999 kΩ
(1.1 to 3.299 99) kΩ
(3.3 to 10.9999) kΩ
(11 to 32.9999) kΩ
(33 to 109.99) kΩ
(110 to 329.999) kΩ
330 kΩ to 1.099 99 MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.999) MΩ
(110 to 330) MΩ
0.053 % + 0.006 Ω
0.034 % + 0.01 Ω
0.014 % + 0.01 Ω
0.0094 % + 0.01 Ω
0.011 % + 0.06 Ω
0.0085 % + 0.06 Ω
0.011 % + 0.6 Ω
0.0085 % + 0.6 Ω
0.013 % + 6 Ω
0.011 % + 6 Ω
0.016 % + 55 Ω
0.013 % + 55 Ω
0.050 % + 0.55 kΩ
0.079 % + 0.55 kΩ
0.39 % + 5.5 kΩ
0.39 % + 17 kΩ
Fluke 5500A/
SC600
Resistance – Measure
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
0.0052 % + 0.0014 Ω
0.0035 % + 0.002 Ω
0.0035 % + 0.02 Ω
0.0036 % + 0.2 Ω
0.0039 % + 2 Ω
0.016 % + 50 Ω
0.067 % + 3 kΩ
Agilent 34401A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4167.01) 05/30/2025 Page 3 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(1 to 32.999) mV
(33 to 329.999) mV
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
45 Hz to 1 kHz
(1 to 10) kHz
45 Hz to 1 kHz
0.17 % + 20 μV
0.20 % + 20 μV
0.24 % + 20 μV
0.045 % + 20 μV
0.085 % + 20 μV
0.13 % + 40 μV
0.029 % + 60 μV
0.064 % + 60 μV
0.12 % + 0.3 mV
0.035 % + 0.6 mV
0.068 % + 2.6 mV
0.16 % + 5.0 mV
0.045 % + 6.6 mV
0.063 % + 15 μV
0.046 % + 80 mV
Fluke
5500A/SC600
AC Voltage – Measure
100.000 mV
1.000 00 V
10.0000 V
100.000 V
750.00 V
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
0.043 % + 8 μV
0.041 % + 50 μV
0.020 % + 0.2 mV
0.025 % + 2 mV
0.042 % + 10 mV
Agilent 34401A
AC Current – Generate
(0.029 to 0.329 99) mA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 2.199 99) A
(2.2 to 11) A
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
(45 to 65) Hz
0.16 % + 0.25 μA
0.087 % + 0.30 μA
0.078 % + 3 μA
0.081 % + 30 μA
0.090 % + 0.3 mA
0.061 % + 2 mA
Fluke
5500A/SC600
AC Current – Measure
1.000 000 A
3.000 00 A
10 Hz to 5 kHz
10 Hz to 5 kHz
0.092 % + 0.2 mA
0.080 % + 0.2 mA
Agilent 34401A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4167.01) 05/30/2025 Page 4 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
Capacitance – Generate
(0.000 33 to 0.0005) μF
(0.0006 to 0.0011) μF
(0.0012 to 0.0033) μF
(0.0034 to 0.011) μF
(0.012 to 0.033) μF
(0.034 to 0.11) μF
(0.12 to 0.33) μF
(0.34 to 1.1) μF
(1.2 to 3.3) μF
(3.3 to 11) μF
(12 to 33) μF
(34 to 110) μF
(111 to 1100) μF
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 1000) Hz
(50 to 400) Hz
(50 to 400) Hz
(50 to 200) Hz
(50 to 100) Hz
(50 to 100) Hz
2.0 % + 0.000 01 μF
1.1 % + 0.000 01 μF
0.63 % + 0.000 01 μF
0.46 % + 0.000 01 μF
0.43 % + 0.0001 μF
0.26 % + 0.0001 μF
0.26 % + 0.0003 μF
0.26 % + 0.001 μF
0.34 % + 0.003 μF
0.45 % + 0.01 μF
0.51 % + 0.03 μF
0.46 % + 0.1 μF
0.61 % + 0.3 μF
0.80 % + 0.3 μF
Fluke
5500A/SC600
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Electrical Simulation of
Thermocouples – Generate
and Measure
Type B
Type E
Type K
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
0.51 °C
0.39 °C
0.35 °C
0.40 °C
0.58 °C
0.19 °C
0.16 °C
0.19 °C
0.24 °C
0.41 °C
0.22 °C
0.2 °C
0.3 °C
0.46 °C
Fluke
5500A/SC600
_______________________________________________________
1 This laboratory offers commercial calibration. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4167.01) 05/30/2025 Page 5 of 5
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. All calibrations will take place within 23 plus or minus 5 ° C.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aldinger Company DBA Quality Control ServicesMilwaukie, ORA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994