ISO 11452-4 Accredited Testing Labs in United Kingdom

8 laboratories in United Kingdom are accredited by UKAS under ISO/IEC 17025 to perform ISO 11452-4 testing. From the accredited scope text: “ISO 11452-4:1995 1 MHz to 400 MHz A, B ISO 11452-4:2005 including Corrigendum 1:2009 excluding clause 7.6.2; Figure 2 and clause 8.3.2 A, B ISO 11452-4:2011 excluding clauses 6.2, 7.6.2 & E.1.2 A, B I” “ISO 11452-4:2011 (excludes TWC) A A 10.3.4 Vehicular Transient ISO 7637-1:1990 A, C Testing ISO 7637-2:1990 12 and 24 V ISO 7637-2:2004, pulses 1, 2a, 2b, Emissions and 3a, 3b and 4 only ISO 16750-2:2” “ISO 11452-4:2001 15 V rms Injection via coupling 2004/104/EC Annex IX networks, direct current 11452-4:2005 injection or bulk current injection ECE Regulation 10.6** EN 61000-4-6:2009 IEC 61000-4-6:20” “ISO 11452-4:2001 A, B 150 kHz to 230 MHz ISO 11452-4:2005, subst. method ISO 11452-4:2011 (excluding TWC RF Voltage up to 10 Vrms test method) ISO 11452-4:2020 (excluding TWC BCI 100 kHz to 400 MHz te”

Labs
8
Primary AB
UKAS8 labs

Accredited Labs

TUV SUD Limited (Trading as TUV SUD)

Hampshire, GB

Scope

ISO 11452-4:1995 1 MHz to 400 MHz A, B ISO 11452-4:2005 including Corrigendum 1:2009 excluding clause 7.6.2; Figure 2 and clause 8.3.2 A, B ISO 11452-4:2011 excluding clauses 6.2, 7.6.2 & E.1.2 A, B ISO 11452-5:2002 A, B SAMA

View lab

UL International (UK)

Hampshire, GB

Scope

ISO 11452-4:2001 15 V rms Injection via coupling 2004/104/EC Annex IX networks, direct current 11452-4:2005 injection or bulk current injection ECE Regulation 10.6** EN

View lab

Element Materials Technology Warwick

Worcestershire, GB

Scope

ISO 11452-4:2011 (excludes TWC) A A 10.3.4 Vehicular Transient ISO 7637-1:1990 A, C Testing ISO 7637-2:1990 12 and 24 V ISO 7637-2:2004, pulses 1, 2a, 2b, Emissions and 3a, 3b and 4 only ISO 16750-2:2012 Section 4

View lab

3C Test

Northamptonshire, GB

Scope

ISO 11452-4:2001 A, B 150 kHz to 230 MHz ISO 11452-4:2005, subst. method ISO 11452-4:2011 (excluding TWC RF Voltage up to 10 Vrms test method) ISO 11452-4:2020 (excluding TWC BCI 100 kHz to 40

View lab

Electromagnetic Testing Services

Essex, GB

Scope

ISO 11452-4:2005 2.5 Transient Immunity UNECE Reg 10.5 Conducted immunity on supply lines ISO 7637-2:2004 + A1:2008 2.6 Radiated Immunity ISO 11452-2:2004 Absorption Chamber Substitution meth

View lab

ZF Automotive UK

West Midlands, GB

Scope

ISO 11452-4:1995 ISO 11452-4:2001 ISO 11452-4:2005 ISO 11452-4:2011 BS3G100:Part 4: Section 2 1973/1980 UNECE Regulation 10.06 including Amendment 1: 2020 DEF STAN 59-41: Issue 3:1988 DEF STAN 59-41: Issue 5:1995 Sup

View lab

Skyships Automotive

Chelmsford, GB

Scope

ISO 11452-4:2001 ISO 11452-4:2005 ISO 11452-4:2020 (excluding TWC and HV/AN methods for high voltage or shielded power systems) 1.6 Electrostatic Discharge Immunity: ISO 10605:2001 ISO 10605:2008

View lab

Kiwa Ltd t/a Kiwa Electrical Compliance

Essex, GB

Scope

ISO 11452-4:2005 (substitution method only) ISO 11452-4:2011 (substitution method only) 1.2.4 Vehicle Transient ISO 7637-2:2004 Emissions and Immunity Pulses 1, 2a, 2b, 3a, 3b & 4 12 and 24 v Systems UN Regula

View lab
Refine these results

This page is a fixed slice of the register: every ISO 11452-4 scope we hold for United Kingdom. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United Kingdom

Top matrices for ISO 11452-4 in United Kingdom

About ISO/IEC 17025 in United Kingdom

United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches