CMT Technical Services
Stafford, TX, US
ASTM E709 Magnetic Particle Testing 1 This laboratory performs field testing activities for these tests.
24 laboratories in United States are accredited by A2LA to perform ASTM E709 testing. We don't know yet whether 4 of them take outside work. From the accredited scope text: “ASTM E709 Magnetic Particle Testing (Dry & Wet - Yoke Method) AWS D1.1 (Clause 6 Inspection); AWS D1.3 (Clause 6 Inspection); AWS D1.5 (Clause 6 Inspection) Visual Weld Inspection AISC Section 16.1 N5” “ASTM E709 Magnetic Particle Testing 1 This laboratory performs field testing activities for these tests.” “ASTM E709; ASME Section V (Article 7) Magnetic Particle Testing (Dry - Yoke Method)” “ASTM E7091 (Yoke - Dry) Magnetic Particle Testing AWS D1.1 (Clause 6 Part C) Magnetic Particle Testing AWS D1.8 (Annex G) Magnetic Particle Testing ASTM E797, E164, E587 (Contact Straight Beam, Contac”
Stafford, TX, US
ASTM E709 Magnetic Particle Testing 1 This laboratory performs field testing activities for these tests.
Houston, TX, US
ASTM E709, E1444; ANSI/ASME B31.1, B31.3; API 1104, 6A; ASME Section V, Article 7; MIL STD 1949; AWS D1.1 (Clause 6 Part C, Clause 9 Part F) Radiographic1, 2 X-ray Gamma ASTM E94, ASTM E1742, ASTM E2033; ANSI/ASME B31.1, B31.3; AP
Whitmore Lake, MI, US
ASTM E709), D17.1/D17.1M (sec. 7.3.2, ASTM E1444/E1444M); ASTM E709; NAVSEA T9074-AS-GIB-010/271 (sec. 4); ASTM E3024 Visual Inspection ASME BPVC Section V, Article 9; AWS D1.1/D1.1M (sec. 8, part A, B, & C), D1.2/D1.2M (sec.
Houston, TX, US
ASTM E709; ASME Section V (Article 7) Magnetic Particle Testing (Dry - Yoke Method)
Marietta, GA, US
ASTM E709; EN 1290; API-1104; NAVSEA T9704-AS-GIB-010/271
Tukwila, WA, US
ASTM E709 Standard Guide for Magnetic Particle Testing 1 This laboratory performs field testing activities for these tests. SATELLITE LOCATION PROFESSIONAL SERVICE INDUSTRIES, INC. 104 E 9th St. Wenatchee, WA 98801 Eric Allen
Dayton, OH, US
ASTM E709, E3024 (Yoke Dry Visible and Wet Fluorescent)1 E1444/E1444M; P3TF9, P3TF48; IFC40-932-01E; NAVSEA T9074-AS-GIB-010/271 Radiography (X-ray Film) ASTM E94/E94M, E1742/E1742M, E2104; P3TF5; RRP58006; NAVSEA T9074-AS-GIB-010/2
Tonawanda, NY, US
ASTM E709 Tensile Testing* ASME Sec. IX; API 1104; AWS D1.1/D1.1M, D1.2/D1.2M, D1.3/D1.3M, D1.5M/D1.5, D1.6/D1.6M, D9.1/D9.1M, D14.1/D14.1M, D14.4/D14.4M, D14.6/D14.6M, D14.9/D14.9M, D15.1/D15.1M, D17.1/D17.1M Bend Testing* ASME Sec.
Erie, PA, US
ASTM E709, E1444/E1444M; MIL-STD-271F (Canceled 1998, Replaced by NAVSEA T9074-AS- GIB-010/271), MIL-STD-1949 (Canceled 1993, Replaced by ASTM E1444)
Wilsonville, OR, US
ASTM E7091 (Yoke - Dry) Magnetic Particle Testing AWS D1.1 (Clause 6 Part C) Magnetic Particle Testing AWS D1.8 (Annex G) Magnetic Particle Testing ASTM E797, E164, E587 (Contact Straight Beam, Contact Angled Beam) Ultrasonic Testing
Seattle, WA, US
ASTM E709 Magnetic Particle Testing (Wet & Dry Methods with Yoke in AC/DC Mode)
Portland, OR, US
ASTM E709, E3024/E3024M; AWS D1.1/D1.M, D1.2/D1.2M, D1.3/D1.3M, D1.5M/D1.5, D1.6/D1.6M, D1.9/D1.9M, D4.1/D14.1M, ASME Section IX Structural Welding AWS D1.1/D1.1M, Clause 8 (A, B, and C) & Clause 6, AWS D1.1/D1.M, D1.2/D1.2M, D1.3/
Johnstown, PA, US
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 RNDT, INC. 228 Maple Avenue Johnstown, PA 15901 Kevin R. McMonagle Phone: 814 535 5448 Email: kevin@rndt.net NONDESTRUCTIVE Valid To: January 31, 2028
Winona, MN, US
ASTM E709, E1444/E1444M; NAVSEA T9074-AS-GIB-01/27 ASTM E165/E165M, E1417/E1417M, NAVSEA T9074-AS-GIB-01/27 Chemical Analysis Spark Atomic Emission Spectroscopy C & low alloy steel Austenitic Stain
Bloomington, MN, US
ASTM E709, E1444/E1444M; ASME V (Article 7), VIII (Appendix 6), B31.1 (Chapter VI), B31.3 (Chapter VI), B16.34 (Appendix II); AWS D1.1/D1.1M (Clause 8 & Clause 10 Part F), D1.5/D1.5M (Clause 8), D14.1/D14.1M (Clause 9), D17.1/D17.1M (
Houston, TX, US
ASTM E709 Magnetic Particle Testing 1 This laboratory performs field testing activities for these tests.
Bellingham, WA, US
ASTM E709 Magnetic Particle1 Yoke – Visible (Dry) ASTM E1444 Magnetic Particle1 Yoke – Visible (Dry) AWS D1.1 & D1.8 (Clause 6 Part C, Clause 9 Part F) Magnetic Particle1 Yoke – Visible (Dry) Building Envelope ASTM E783 Field M
Fort Myers, FL, US
ASTM E709
Vancouver , WA, US
ASTM E709 Standard Guide for Magnetic Particle Testing - AC Yoke , Wet/Dry ASTM E164 Contact Ultrasonic Testing of Weldments - Straight & Angle AWS D1.1 Structural Welding Code – Steel (Clause 8, Inspection) AWS D1.3 Structural Welding
Houston, TX, US
ASTM E709 Magnetic Particle Testing (Dry & Wet - Yoke Method) AWS D1.1 (Clause 6 Inspection); AWS D1.3 (Clause 6 Inspection); AWS D1.5 (Clause 6 Inspection) Visual Weld Inspection AISC Section 16.1 N5.6 / RCSC, Section 9 Inspection
Jackson, MI, US
ASTM E709, ASTM E3024/E3024M; ASME Section V, Art. 7, ASME SE709 Ultrasonic (Contact Method, Straight and Angle Beam) ASTM E114, ASTM E164, ASTM E273, ASTM E587, ASTM E797/E797M; ASME Section V, Art. 4 Visual AWS D1.1/D1.
Frankfort, IN, US
ASTM E709 (Wet magnetic particle technique) I. Dimensional Testing1 Parameter/Equipment Range CMC2 (±) Technique / Method Length3 - 1D Up to 6 in Up to 12 in Up to 1 in (1 to 2) in 0.002 in 0.002 i
Wallingford, CT, US
ASTM E709, ASTM E1444 I. Dimensional Testing1 Parameter Range CMC2 (±) Technique/Method Internal Socket3 (0.050 to 1.00) in (1.5 to 32) mm N/A N/A Hex Go/No-Go/ASME B18.3 Hex Go/No-Go/ASME B18.3.1M L
Saginaw, MI, US
ASTM E709 (2015), ASTM E1444 (2016) 1This laboratory’s scope contains withdrawn or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered “historical” and not that th
American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.