South Holland Metal Finishing
Monee, IL, US
ISO 16047; SAE/USCAR 10, 11
20 laboratories in United States are accredited by A2LA to perform ISO 16047 testing. We don't know yet whether 14 of them take outside work. From the accredited scope text: “ISO 16047 Torque Testing ASTM F738 (Sec. 10.2.4), F880 (Sec. 12.3),” “ISO 16047; LTP11 LTP 2 Automatic1, LTP 3 Manual1 LTP 18 Automatic, LTP 14 Manual LTP 21 Automatic, LTP 4 Manual GMW 14334 Class B; LTP 29, LTP 301 Plating Lab: Cass Salt Spray Thickness of Platings (x” “ISO 16047; GMW3044, GMW16819, GMW 3359; Ford WZ100, Ford WZ101; JDM F15, F22, F23, F26; SAE J1965 Prevailing Torque ASME B18.16.6, B18.16.6M; IFI 124, IFI 125, IFI 524, IFI 525; Ford ES-21006-S100; WS” “ISO 16047; GM9064P (Superseded November 2012) Chemical Tests Brookfield Viscosity Up to 8,000,000 cPs ASTM D1084 Method B, ASTM D2556; ISO 2555 Zahn Cup Viscosity Cup #2 & #3 ASTM D1084 Method D, ASTM”
Monee, IL, US
ISO 16047; SAE/USCAR 10, 11
Cleveland, OH, US
ISO 16047 Torque Testing ASTM F738 (Sec. 10.2.4), F880 (Sec. 12.3),
Lakeside, CA, US
ISO 16047
Machesney Park, IL, US
ISO 16047; SAE J1965; SAE/USCAR10; USCAR11; TP-02 In-Joint Torque/Tension with Ultrasonics
Winona, MN, US
ISO 16047 Metallographic Evaluation Macro-etch Testing Steel Bars, Billets, Blooms, and Forgings ASTM E381 Case Depth SAE J423, J78, J81, J933 Decarburization ASTM F835, F835M (2015), F2328; ISO 898-1, 898-5; SAE
Tipp City, OH, US
ISO 16047; GMW3044, GMW16819, GMW 3359; Ford WZ100, Ford WZ101; JDM F15, F22, F23, F26; SAE J1965 Prevailing Torque ASME B18.16.6, B18.16.6M; IFI 124, IFI 125, IFI 524, IFI 525; Ford ES-21006-S100; WSD-M21P27-A4 GM6175M, GM6194M, GM6
Addison, IL, US
ISO 16047 Metallurgical Case Depth GM6010M1 (4.3) (Inactive 2011), GM6171M1 (4.3) (Inactive 2011); SAE J81 (3.3), J933 (3.3), J1237 (4.3) Coating Thickness by X-Ray Fluorescence ASTM B568 Decarburization ASTM F2328 S
Addison, IL, US
ISO 16047, JDM F27 1This laboratory’s scope contains inactive, withdrawn, or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered “historical” and not that the l
Frankfort, IN, US
ISO 16047 Torque Tension ISO 16047 Assembly Installation Tension Test ASTM F3125/F3125M Metallographic Evaluation Coating Thickness (Eddy Current & X-ray) ASTM B568, ASTM E376 Decarburization & Case Depth (Optical & Hardn
Sterling Heights, MI, US
ISO 16047; SAE/USCAR-10, -11 Salt Fog ASTM B117; ISO 9227; GMW 3286; SAE/USCAR-1 Coating Thickness Electromagnetic ASTM B499, E376 Coating Weigh t Gravimetric ASTM A90/A90M, B767
Independence, OH, US
ISO 16047 Torque to Failure Ford FST-10, TM-00.00-L-10704; Navistar MAT-WI-013
Utica, MI, US
ISO 16047; SAE/USCAR 10, 11 FORD WA970, WX200, WZ100, WZ101, ESS-M11P24-A1, ESS-M11P24-A2 A2 (2013); MNP SOP 525, 526; GMW 25, GMW 3359 I. Dimensional Testing2: Parameter/Equipment Range CMC3 (±) Comments Torque Angle
Port Huron, MI, US
ISO 16047; USCAR-10, -11 (Both stabilized 2020); DTNA – 49-00231-007, DTNA – 49-00231-009 Coating Thickness (MMS) Measurement ASTM B499 Cyclic Corrosion Testing (CCT)
Orchard Park, NY, US
ISO 16047; LTP11 LTP 2 Automatic1, LTP 3 Manual1 LTP 18 Automatic, LTP 14 Manual LTP 21 Automatic, LTP 4 Manual GMW 14334 Class B; LTP 29, LTP 301 Plating Lab: Cass Salt Spray Thickness of Platings (x-ray) Adhesion (Saw/Grind)
Madison Heights, MI, US
ISO 16047 Tensile Testing Axial/Wedge F606/F606M used to satisfy ISO 898-1 requirements; FMVSS 571.209 Rockwell Hardness (C) ASTM E18 Hydrogen Embrittlement (Torque Method) SAE/USCAR 7 I. Dimensional Testing2
Chardon, OH, US
ISO 16047 (International); ISO 2320 (International); IFI 101; VDA 235-203; VW 01129, VW 011331-1, VW 01131-2 HTES-1107, HTES-1105, HTES-1161 Scanning Electron Microscope (SEM) ASTM B487; ISO 1463; ASTM B748 1 All QP test methods
Troy, MI, US
ISO 16047; GM9064P (Superseded November 2012) Chemical Tests Brookfield Viscosity Up to 8,000,000 cPs ASTM D1084 Method B, ASTM D2556; ISO 2555 Zahn Cup Viscosity Cup #2 & #3 ASTM D1084 Method D, ASTM D4212
Roseville, MI, US
ISO 16047
New Hudson, MI, US
ISO 16047; USCAR-10, USCAR-11; Presence of Hexavalent Chromium in Chromate Coatings ISO 3613 (Section 6.5.3, 6.5.4) Calcium Chloride (Russian) Mud ASTM B995; Nissan M4063 (Section 4.5.2) Microindentation Hardness ASTM B57
Greenwood, IN, US
ISO 16047 II. Dimensional Testing2: Parameter/Equipment Range CMC3 (±) Comments Length4 – 1-Dimensional 3-Dimensional Up to 3 in Up to 75 mm Up to 6 in Up to 8 in Up to 12 in
American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.