FindTestingLabs

Gage block Testing Labs in United States

15 laboratories in United States are accredited by A2LA under ISO/IEC 17025 to perform Gage block testing. Most frequently tested analytes in this matrix in United States: Length, Ph. Accredited providers include Technical Maintenance, Inc. - PEACHTREE CORNERS, Technical Maintenance, Inc. - COLORADO SPRINGS, Technical Maintenance, Inc. - TEMPLE TERRACE, Technical Maintenance, Inc. - WINDSOR, NOVASTAR SOLUTIONS.COM LLC DBA NOVASTAR METROLOGY. Sites located in Peachtree Corners, GA, Colorado Springs, CO, Temple Terrace, FL, Suite B Windsor, CT, Livonia, MI.

Labs
15
Top method
Top analyte
Length
1 labs
Primary AB
A2LA
15 labs

Accredited Labs

Technical Maintenance, Inc. - PEACHTREE CORNERS
Peachtree Corners, GA, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Technical Maintenance, Inc. - COLORADO SPRINGS
Colorado Springs, CO, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Technical Maintenance, Inc. - TEMPLE TERRACE
Temple Terrace, FL, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

Technical Maintenance, Inc. - WINDSOR
Suite B Windsor, CT, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

NOVASTAR SOLUTIONS.COM LLC DBA NOVASTAR METROLOGY
Livonia, MI, US

(A2LA Cert. No. 1277.01) Revised 07/16/2025 Page 2 of 24 II. Chemical Parameter/Equipment Range CMC2, 6, 10 (±) Comments pH3 – Measuring Equipment 4.01 pH unit 7.01 pH unit 10.01 pH unit 0.019 pH unit

Global Mozon Laboratory for calibration and Supporting Services
Yanbu, US

(A2LA Cert. No. 4218.01) Revised 12/24/2025 Page 14 of 26 Parameter/Equipment Range CMC2, 4 (±) Comments Location9 Dial Indicators Up to 25 mm (≥ 25 to 50) mm 6 μm 10 μm VDI/VDE/DGQ 2618 Steel &

International Process Solutions
San Carlos, CA, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

Technical Maintenance, Inc. - Dallas
Dallas, TX, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

Technical Maintenance, Inc. - MADISON
Madison, AL, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Technical Maintenance, Inc. - POMPANO BEACH
Pompano Beach, FL, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Technical Maintenance, Inc. - HILLIARD
Hilliard, OH, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Micro Quality Calibration
Chatsworth, CA, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Technical Maintenance, Inc. - MELBOURNE
Melbourne, FL, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

Technical Maintenance, Inc. - ROCKFORD
Rockford, IL, US

Page 163 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Indicators Test3 – Up to 0.05 in Up to 1.25 mm 15 µin 0.38 µm Calibration tester, gage blocks Cylindri

Technical Maintenance, Inc. - MORRISVILLE
Morrisville, NC, US

Page 162 of 205 (A2LA Cert. No. 2348.01) Revised 03/04/2026 Parameter/Equipment Range CMC2, 8 (±) Comments Gage Block – Parallelism Up to 4 in Up to 100 mm (5 to 20) in (125 to 500) mm 2.7 µin 0.069 µm 1.6 µin 0.04

Top analytes for Gage block in United States

  • Length (1)
  • Ph (1)

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.