FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates

EN 1363-2 Accredited Testing Labs Worldwide

Part of a series

See all 20 labs worldwide for EN 1363 (any part)

Part 1: 19 labs · Part 2: 20 labs

Go to the series ↑

20 accredited laboratories in 7 countries hold EN 1363-2 in their ISO/IEC 17025 scope. Primary accreditors include Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, EN 1363-2 scope entries most often cover Insulation, Thermal Insulation in Steel, Building materials, Food industry environment samples.

Total labs
20
Countries
7

Available in 7 Countries

United Kingdom
7 labs
Germany
7 labs
Italy
2 labs
Poland
2 labs
United States
1 lab
Sweden
1 lab
United Arab Emirates
1 lab

Top matrices for EN 1363-2

Top analytes for EN 1363-2

  • Insulation (1)
  • Thermal Insulation (1)

Sample labs

UL International Germany
Neu-Isenburg, DE

This document is a translation. The definitive version is the original German annex to the accreditation certificate. The testing laboratory is permitted to use standardised or equivalent test methods listed here with different issue da

Cambridge Fire Research
Cambridge, GB

EN 1363-2:1999, Section 8 Walls and partitions Fire resistance BS 476 Part 22:1987, Section 5 BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987, Sections 6, 7 and 8 BS EN 1634-1:2014+A1:2018

CERTBUD Sp. z o.o.
Warszawa, PL

EN 1363-2:2001 PN-EN 13501-2:2023-09 * Systemy transportowe i ich zamknięcia Szczelność ogniowa, izolacyjność ogniowa, natężenie promieniowania, samozamykalność - utrzymywanie się płomienia - otwory i pęknięcia - zapalenie tamponu

DMT GmbH & Co. KG Prüfstelle für Brandschutz
Dortmund, DE

3 Standort Verl (V) 3.1 Feuerwiderstand DIN EN 1363 -1 2020-05 Feuerwiderstandsprüfungen - Teil 1: Allgemeine Anforderungen DIN EN 1363 -2 1999-10 Feuerwiderstandsprüfungen - Teil 2: Alternative und ergänzende Verfahren DIN

Efectis UK/Ireland
Jordanstown, GB

EN 1363-2:1999 EN 1363-2:1999 Jordanstown Cardiff STRUCTURAL MEMBERS Resistance to fire tests Horizontal protective membranes. BS EN 13381-1:2020 EN 13381-1:2020 Jordanstown Vertical protective membranes. B

Vetrotech Saint-Gobain (International) AG IFTS International Fire Testing + Services
Herzogenrath, DE

Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist, ohne dass es einer vorher igen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormt en oder ihnen gleichzusetzenden Prüfverfahren mit unter

RISE Research Institutes of Sweden
Lund, SE

EN 1363-2 Brandmotstånd Byggprodukter Ja 2 Nej EN 1364-1 Brandmotstånd Byggprodukter Ja 2 Nej EN 1364-2 Brandmotstånd Byggprodukter Ja 2 Nej EN 1365-1 Brandmotstånd Byggprodukter Ja 2 Nej EN 1365-2 Brandmotstånd Byggprodukter Ja 2 Nej EN 13

Materialprüfanstalt für das Bauwesen (MPA BS) Fachbereich 1 - Konstruktionen und Baustoffe Fachbereich 2 - Brandschutz
Braunschweig, DE

This document is a translation. The definitive version is the original German annex to the accreditation certificate. 2 Department 2 - Fire Safety 2.1 Fire behaviour of building materials and building components ISO 1928 2020-1

ift Rosenheim
Rosenheim, DE

BS 476 -22 1987 Fire tests on building materials and structures – Part 22: Methods for determination of the fire resistance of non-loadbearing elements of construction OF21 DIN 4102 -2 1977 -09 Brandverhalten von Baustoffe

Saint-Gobain Construction Products UK LTD t/a The Building Test Centre
Leicestershire, GB

EN 1363-2: 1999 BS EN 13381-2:2014 ASTM E119 (excluding hose stream test) A LIGHTWEIGHT PARTITIONS – NON- LOADBEARING Extended application of results from fire resistance tests BS EN 15254-3:2019 A FLOORS and FLAT ROOFS

Intertek Testing Services NA
Kentwood, MI, US

EN 1363-2 Fire resistance tests - elements of building construction part 2: alternative and additional procedures EN 1364-1 Fire resistance tests for non-loadbearing elements – part 1: walls EN 1365-1 Fire resistance tests for loadb

Attain RTC
North Yorkshire, GB

EN 1363-2:1999 BS 476 :Part 20 :1987 WALLS and PARTITIONS Fire Resistance BS 476:Part 22:1987 Clause 5 BS EN 1364-1:2015 DOORS & SHUTTER ASSEMBLIES Fire Resistance BS 476:Part 22:1987 Clause 6,7 & 8. BS EN 1634-1:2014

United Kingdom Testing & Certification
Glasgow, GB

EN 1363-2:1999 – Section 8 CAVITY BARRIERS Fire Resistance - vertical specimens EOTA Technical Report 31:2008 DOOR and SHUTTER ASSEMBLIES and ARCHITECTURAL HARDWARE Fire resistance BS 476-22:1987 – Sections 6, 7 & 8 BS EN

CSI SpA
Bollate, IT

EN 1363-2:2001 + UNI EN 15725:2023 + UNI EN 15882-2:2022 Prove al fuoco Resistenza al fuoco/Fire resistance (CPR Annex V.3 Resistance to fire, così come modificato dal REGOLAMENTO DELEGATO (UE) N. 568/2014 DELLA COMMISSIONE del 18 febbra

Centrum Techniki Okrętowej Spółka Akcyjna
Gdańsk, PL

EN 1363-2 z wył./excl. p. 7 PN-EN 13501-4 Przewody oddymiające obsługujące jedną strefę pożarową E Single compartment smoke extraction ducts E Przecieki, m3/(m2h) Zmniejszenie pola przekroju, % Stabilność mechaniczna Lea

RINA SERVICES S.p.A. - LABORATORIO PROVE
Genova, IT

EN 1363-2:1999, UNI EN 1364-1:2015 + UNI EN 1363-1:2020 + UNI EN 1363-2:2001 Prove al fuoco Porte e sistemi di chiusura e finestre apribili/Door and shutter assemblies and openable windows Denominazione della prova / Campi di prova Capa

Thomas Bell-Wright International Consultants
PO Box 26385, Corner of 46th and 47th Streets, Jebel Ali Industrial Area 1, Dubai, United Arab Emirates, GB

EN 1363-2:1999 (Clauses 1 to 6 and clause 8) ISO 834-1:1999 (Amd 1:2012 & Amd 2 :2021) IS/ISO 834-1:1999 (Amd 1:2012) Lab WALLS AND PARTITIONS - Non load bearing Fire resistance EN 1364-1:2015 BS 476 - 22: Se

Warringtonfire Testing and Certification Limited, trading as Warringtonfire
Cheshire, GB

EN 1363-2:1999 A WALLS and PARTITIONS Fire Resistance BS 476:Part 8:1972:Section 2 BS 476:Part 21:1987:Section 8 FTSG Resolutions 47, 88 and 70 BS 476:Part 22:1987:Section 5 ISO 834:1975:Sections 5, 6, 7 and 8 BS EN 1364-1:201

TÜV NORD Systems GmbH & Co. KG Prüfstelle für Brandschutz
Dortmund, DE

3 Standort Verl (V) 3.1 Feuerwiderstand DIN EN 1363 -1 2020-05 Feuerwiderstandsprüfungen - Teil 1: Allgemeine Anforderungen DIN EN 1363 -2 1999-10 Feuerwiderstandsprüfungen - Teil 2: Alternative und ergänzende Verfahren DI

Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Leipzig, DE

17 Brandverhalten von Baustoffen, Bauarten und Bauprodukten - europäisch (La) [Flex A] DIN EN ISO 9239 -1 2010-11 Prüfungen zum Brandverhalten von Bodenbelägen - Teil 1: Bestimmung des Brandverhaltens bei Beanspruchung mit

Other parts