FindTestingLabs
Registers collected 2026-08-22.See collection dates

ISO 9513 Accredited Testing Labs Worldwide

10 accredited laboratories in 2 countries hold ISO 9513 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Comité français d'accréditation.

Total labs
10
Countries
2

Available in 2 Countries

Top analytes for ISO 9513

  • Force (1)
  • Hardness (Brinell, Rockwell, Vickers) (1)
  • Linear Displacement (1)
  • Linear Magnification (1)

Sample labs

Cal-Rite Corporation
Naperville, IL, US

ISO 9513; Gage blocks, extensometer calibrator; uncertainties listed in displacement Gage blocks Caliper Micrometers³ – Up to 6 in (> 6 to 20) in (71 + 0.6R) µin (200 + 0.6R) µin Gage blocks

National Force Calibrations Plus
Chattanooga, TN, US

ISO 9513 Digital caliper Heidenhain glass scale Displacement 3 – Measure (0.001 to 1.0) in (1.0 to 40) in 0.000 062 in 0.0017 in ASTM E 2309 Heidenhain length gages Morehouse readout linear

CERIB
EPERNON, FR

NF EN ISO 9513 / Sur site

Instru-Met Corporation
Union, NJ, US

ISO 9513 ASTM E2309 Using precision micrometer system or linear precision scale Gage blocks Testing Machine Crosshead Speed 3 – Measure Displacement Time (0.002 to 50) in/min -- 37 μ

ZWICKROELL
ARS-LAQUENEXY, FR

ISO 9513 ASTM E83 Principaux moyens utilisés : Banc micrométrique et capteurs de déplacement Sur site Portée flexible FLEX1 : le laboratoire est reconnu compétent pour pratiquer les méthodes référencées et leurs révisions ultérieure

TRESCAL
RUNGIS, FR

ISO 9513 ASTM E83 Principaux moyens utilisés : Banc micrométrique Sur site Portée flexible FLEX1 : Le laboratoire est reconnu compétent pour pratiquer les méthodes référencées et leurs révisions ultérieures .

TESTCAL PLUS
Riverview, MI, US

ISO 9513 using digital high accuracy length scale Scales & Balances 3 (0.01 to 1000) lbf 4.5 g to 454 kg 0.01 % + 0.6R Master dead weights ASTM E898 Torque 3 – Measuring Equipment (0.1 to 150) lbf∙ft (0.136 t

MTS Systems Corporation - MTS Calibration Organization
Eden Prairie, MN, US

ISO 9513 Extensometer calibrator Laser interferometer Extensometer calibrator (excluding ASTM E399) Optical & extensometer calibrator Caliper North America, Japan Norden North America, Japan

Martin Calibration, Inc dba Great Lakes Calibration,
Suite E Addison, IL, US

Parameter/Equipment Range CMC2, 4, 7 () Comments Optical Comparators 3 – Linear Magnification Angle Up to 12 in Up to 100x (15,30,45,60,90, 120,150,180,270,360) deg (120 + 3.8L + 0.6R)

MI METROLOGIE - OSTWALD
OSTWALD, FR

ISO 9513 ASTM E83 ASTM E2309 / Sur site Extensomètres Dispositifs d'allongement Longueur Vérification d’extensomètre par variation de longueur, comparaison à une chaine de mesure de déplacement (banc micrométrique) Méthode interne