Hoffer Calibration Services, LLC (a Subsidiary of Hoffer Flow Controls, Inc.)
107 Kitty Hawk Lane, 27909, Elizabeth City, NC, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 4916.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | Light Hydrocarbons | See scope document |
| 2 | - | Water; Liquid Nitrogen, Liquid Oxygen, and Liquid Argon; Liquid Carbon Dioxide (CO2)Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4916.01) 04/18/2024 Page 2 of 3
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Volumetric Flow Rate –
Measure & Measuring
Equipment (cont)
Water
(1.0 to 260) gpm
(3.785 to 984.207) lpm
(0.75 to 243) gpm
(2.839 to 919.855) lpm
(5.0 to 1525) gpm
(18.927 to 5772.753) lpm
0.20 %
0.20 %
0.20 %
Transfer standard
Volumetric Flow Rate3 –
Measure & Measuring
Equipment
Cryogenic –
Liquid Nitrogen, Liquid
Oxygen, and Liquid
Argon
Liquid Carbon
Dioxide (CO
2)
(20 to 60) gpm
(75.708 to 227.124) lpm
(20 to 130) gpm
(75.708 to 492.102) lpm
(20 to 200) gpm
(75.708 to 757.082) lpm
(20 to 60) gpm
(75.708 to 227.124) lpm
(20 to 130) gpm
(75.708 to 492.102) lpm
(20 to 200) gpm
(75.708 to 757.082) lpm
0.60 %
0.60 %
0.60 %
0.40 %
0.40 %
0.40 %
Prover 1''
Prover 1 1/2''
Prover 2''
Prover 1''
Prover 1 1/2''
Prover 2''
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service. | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4916.01) 04/18/2024 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - Norfolk, NCELIZABETH CITY, NC · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - HamptonHampton, VA · ~81 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VA · ~100 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TRESCAL, INC. - Richmond, VAProvidence Forge, VA · ~147 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SP HB Instrument Calibration LaboratoryPocomoke City, MD · ~206 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.