Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

ASTM B568 Accredited Testing Labs in United States

18 laboratories in United States are accredited by A2LA to perform ASTM B568 testing. We don't know yet whether 15 of them take outside work. From the accredited scope text: “ASTM B568 Metallography: Microetching ASTM E407 Microhardness Knoop and Vickers (100 gf, 500 gf) ASTM E384 Preparation ASTM E3 Environmental Simulation: Humidity (Steady State and Cyclic) EIA 364-31;” “ASTM B568 ________________ 1 This laboratory’s scope contains cancelled or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered” “ASTM B568 and ISO guide 33:2015, 10.1.3 and 10.3.2 ASTM B568 by x-ray ratio method II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Coating Thickness – Measurement Equipment3 Up to 5000” “ASTM B568 Cleanliness Particle Size ISO 16232 Cleanliness Particle Weight ISO 16232 Salt Spray ASTM B117; ISO-9227; GMW3286; USCAR-1 Drive Testing (≤ 200 N-m) ANSI/ASME B18.6.4 and 2.91.1; CHRYSLER MS”

Labs
18
Primary AB
A2LA18 labs

Accredited Labs

South Holland Metal Finishing

Monee, IL, US

Scope

ASTM B568 Rockwell Hardness (A, B, C, 15N, 30N) ASTM E18 Salt Spray ASTM B117; ISO 9227 Torque Tension GMW 3044; ISO 16047; SAE/USCAR 10, 11

View lab

Hitachi High-Tech America

Westford, MA, US

Scope

ASTM B568 and ISO guide 33:2015, 10.1.3 and 10.3.2 ASTM B568 by x-ray ratio method II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Coating Thickness – Measurement Equipment3 U

View lab

Fischer Technology, Inc. USA

Windsor, CT, US

Scope

ASTM B568 X-ray fluorescence ASTM B568 X-ray fluorescence Digital indicator/ micrometer ASTM B567 - 14 beta backscatter ASTM B504 coulometric method Plated Cu over epoxy ASTM E376 eddy current II. Electrical –

View lab

Morgan Ohare

Addison, IL, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Decarburization ASTM F2328 Salt Spray ASTM B117 1 This laboratory’s scope contains withdrawn or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now cons

View lab

Tintronics Industries

Huntsville, AL, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 (for finish thickness); JESD213A (for confirmation of SnPb finish composition) XRF Analysis AS6171/2; MIL-STD-750; MIL-STD-883 Blacktop Test (Smear and Smudge) AS6171/2 OEM Date Code Verification

View lab

Fontana Fasteners

Frankfort, IN, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568, ASTM E376 Decarburization & Case Depth (Optical & Hardness Methods) ASTM F2328;SAE J419, SAE J423 Microetch & Preparation ASTM E3, ASTM E407 Salt Spray ASTM B117

View lab

MNP Corporation-Technical and Research Services

Utica, MI, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Hardness Rockwell (B, C, 15N, 30N) ASTM E18; SAE J417; ISO 6508-1 Hydrogen Embrittlement SAE/USCAR 7; SAE J78, J81, J773, J1237; PS-50023 Sampling Plans Customer Specs; MNP Control Plans; ASME B18.18; ASTM E1806,

View lab

UPA Technology

West Chester, OH, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 X-Ray fluorescence w/ coating thickness standard Solatron P/N 50 2000 w/ gage blocks CMI PTX w/ETP standard Coating Thickness Measuring Equipment – X-Ray Fluorescence Machines 3 Eddy Current & Magnetic

View lab

Supply Technologies

Solon, OH, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Discontinuities ASTM F788, F812, F837/F837M; ISO 6157-1, 6157-2, 6157-3; SAE J122, J123 (superseded 2012) Drill Test IFI-504; ISO 10666; FIP 1000.7; SAE J78 Drive Test ASME B18.6.3; SAE J81, J933, J1237 Ductility Te

View lab

McGard LLC/L.D. McCauley

Orchard Park, NY, US

We don't know yet whether this lab takes outside work.
Scope

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MCGARD LLC/L.D. MCCAULEY LLC 3875 California Rd. Orchard Park, NY 14127 Dennis James Sieracki Phone: 716 445 0486 MECHANICAL Valid To: February 28, 2026

View lab

Semblex Corporation

Elmhurst, IL, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Cleanliness Particle Size ISO 16232 Cleanliness Particle Weight ISO 16232 Salt Spray ASTM B117; ISO-9227; GMW3286; USCAR-1 Drive Testing (≤ 200 N-m) ANSI/ASME B18.6.4 and 2.91.1; CHRYSLER MS415 (Section 2.6);

View lab

Delta TRAC

Williamsville, NY, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 x-ray fluorescence Foil Standards (0.2 to 40) mils 4.5 % ASTM B499 magnetic induction II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2 (±) Comments Thermocouple

View lab

Riverdale Plating & Heat Treating

Riverdale, IL, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Salt Spray ASTM B117 Case Depth, Effective or Total SAE J423 Decarburization / Carburization ASTM F2328

View lab

AFCI Americas

Etters, PA, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Metallography: Microetching ASTM E407 Microhardness Knoop and Vickers (100 gf, 500 gf) ASTM E384 Preparation ASTM E3 Environmental Simulation: Humidity (Steady State and Cyclic) EIA 364-31; MIL-STD-202-103 Thermal

View lab

WN Global Laboratory

Houston, TX, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 ________________ 1 This laboratory’s scope contains cancelled or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered “historical” and not that the lab

View lab

Wolverine Plating

Roseville, MI, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Salt Spray ASTM B117; ISO 9227; JIS Z2371, JIS H8502; SAE/USCAR-1; DX900158; GMW3286; HES D6001; NES M0140; TSH 1552G Torque-Clamp Force ISO 16047

View lab

MacDermid Enthone Industrial Solutions

New Hudson, MI, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568

View lab

Würth Industrial US

Greenwood, IN, US

We don't know yet whether this lab takes outside work.
Scope

ASTM B568 Hydrogen Embrittlement ASTM F606/F606M; SAE J78, J81, J773, J1237 Proof Load (Internal Threads) ASTM F606/F606M

View lab

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches