FindTestingLabs
Registers collected 2026-08-22.See collection dates
ISO/IEC 17025 directory

ASTM D1654 Accredited Testing Labs in United States

15 laboratories in United States are accredited by A2LA under ISO/IEC 17025 to perform ASTM D1654 testing. From the accredited scope text: “ASTM D1654 Evaluation of Painted or Coated Specimens to Corrosive Environments ASTM D1729 Visual Evaluation of Color Difference of Opaque Materials ASTM D1925-70 (Withdrawn 1995) Test Method for Yello” “ASTM D1654 Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments ASTM D2565 Operating Xenon-Arc Type Light Exposure Apparatus With and Without Water for Exposure of Plastics AS” “ASTM D1654 Evaluation: Tape Adhesion ASTM D3359 Altitude (Barometric Pressure) Temperature Altitude (-1,500 to 70,000) ft (-70 to 140) ºC (-50 to 80) oC 8,000 to 55,000 ft. MIL-STD-810E, Method 500.3;” “ASTM D1654 Alkali Resistance ASTM D1308; Honda HES D2008, D2016, D2021, Honda 5100-SGO-A000 (6-14), Honda 5100-SEO-000 (6-13), Honda HES D6501 (3.24, 3.28), Honda 5100Z-TR0-6001, 5100Z-3MAA-8000, 5100”

Labs
15
Primary AB
A2LA15 labs

Accredited Labs

ACT Test Services

Hillsdale, MI, US

Scope

ASTM D1654; Ford BI 169-01; GM 9102P (2010) GMW15282; ISO 4628-8; ISO 17872; VOLVO STD 1021,2

View lab

Element Broken Arrow

Broken Arrow, OK, US

Scope

Test Test Method(s) Metallographic Evaluation (cont’d) Microhardness Knoop (100 to1000) gf ASTM B578, E92, E384, F606/F606M; NASM 1312-6; NAVSEA S9074-GIB-010/248 Vickers (100 to 1000) gf ASTM B578, E92, E384, F606/F60

View lab

Pridgeon & Clay Advanced Engineering

Grand Rapids, MI, US

Scope

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PRIDGEON & CLAY ADVANCED ENGINEERING LAB 50 Cottage Grove SW Grand Rapids, MI 49507 Brandon Luxford Phone: 616-252-2384 MECHANICAL Valid To: July 31, 2026 Certificate

View lab

Touchstone Systems & Services

Wyoming, MI, US

Scope

Test Test Method(s) ENVIRONMENTAL SIMULATION (cont’d) Immersion ASTM D870, D2248; IEC 60529; FLTM BI 104-01; GM4431M (superseded 2016)2; HES D2016-99A, HES D6501-03; Toyota TSH1505G Moisture / Rain / Icing RTCA/DO-160 C/D/

View lab

Michigan Testing Institute

Sterling Heights, MI, US

Scope

ASTM D1654; FORD FLTM CA 005-01, GM 9102P (Inactive 12/10), 9511P (Inactive 12/10), GMW 3286, 15282, 15288; ISO 9227 (5.2); NISSAN NES M0158, NES M0007 (2014-1) (33); SAE J1389; Stellantis CS.00251; TOYOTA TSH1555G (A), PPS 1001;

View lab

Scientific Control Laboratories, Inc.

Chicago, IL, US

Scope

ASTM D1654 Humidity ASTM D1735, D2247 Salt Spray/CASS ASTM B117, B368 (CASS); ISO 9227 Metallography Coating Thickness ASTM B244, B487, B499; ISO 1463 Discontinuities in Chromium Plating ASTM B456 (Appendix X4 and X5) Micro-Hardne

View lab

Bureau Veritas Consumer Products Services

Sunnyvale, CA, US

Scope

ASTM D1654 Flammability of Blankets ASTM D4151 Standard Test Method for Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Striker Impacted by a Falling Weight (Gardner Impact) ASTM D5420 Flame Resistance of Text

View lab

Element Materials Technology Portland

Hillsboro, OR, US

Scope

ASTM D1654 Evaluation: Tape Adhesion ASTM D3359 Altitude (Barometric Pressure) Temperature Altitude Range: Up to 100,000 ft (-65 to 150) ºC MIL-STD 810 E, F, G, H Methods 500, 520; MIL-STD 202 G Method 105; MIL-STD

View lab

Ghesquiere Plastic Testing

Harper Woods, MI, US

Scope

ASTM D1654, ASTM D2059; Fiat 50180; Ford FLTM BI 004-03, FLTM BI 103-01, FLTM BQ 007-02, FLTM BQ 105-01; GMW3286, GMW14458, GMW15282, GMW16862; Honda HES D6501; ISO 4611, ISO 4628-1, ISO 4628-2, ISO 4628-3, ISO 4628-8, ISO 922

View lab

National Exposure Testing

Sylvania, OH, US

Scope

ASTM D1654; DIN EN ISO 4628-2; DIN EN ISO 4628-3; DIN EN ISO 4628-8; GM 8101G (superseded 2009)1; GM 9102P (superseded 2010)1; GMW15282; GMW15357; GMW15359; ISO 4628-2; ISO 4628-3; ISO 4628-4; ISO 4628-5; ISO 4628-8; ISO 1028

View lab

Intertek Testing Services NA

Kentwood, MI, US

Scope

ASTM D1654; FLTM BO 115-01; GM 9125P Xenon (Interior, Exterior) ASTM D4459; ASTM G26-96 (Withdrawn 2000) 3; ASTM D2565; ASTM G155 (except methods 9 & 10); SAE J1885 (Withdrawn 2008) 3, J1960 (Withdrawn 2008) 3; SAE J2412; SAE J2527;

View lab

ELEMENT MATERIALS TECHNOLOGY DENVER – LONGMONT

Longmont, CO, US

Scope

ASTM D1654 Evaluation: Tape Adhesion ASTM D3359 Altitude (Barometric Pressure) Temperature Altitude (-1,500 to 70,000) ft (-70 to 140) ºC (-50 to 80) oC 8,000 to 55,000 ft. MIL-STD-810E,

View lab

Miami Valley Materials Testing Center

Tipp City, OH, US

Scope

ASTM D1654 Alkali Resistance ASTM D1308; Honda HES D2008, D2016, D2021, Honda 5100-SGO-A000 (6-14), Honda 5100-SEO-000 (6-13), Honda HES D6501 (3.24, 3.28), Honda 5100Z-TR0-6001, 5100Z-3MAA-8000, 5100Z-3MAA-6000, 9000Z-T2A-A000 Coat

View lab

Q-Lab Arizona Desert Testing

Wittmann, AZ, US

Scope

ASTM D1654 Evaluation of Painted or Coated Specimens to Corrosive Environments ASTM D1729 Visual Evaluation of Color Difference of Opaque Materials ASTM D1925-70 (Withdrawn 1995) Test Method for Yellowness Index of Plastics

View lab

Atlas Weathering Services Group

Miami, FL, US

Scope

ASTM D1654 Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments ASTM D2565 Operating Xenon-Arc Type Light Exposure Apparatus With and Without Water for Exposure of Plastics ASTM D2803 Standard Guide for Testing F

View lab
Refine these results

This page is a fixed slice of the register: every ASTM D1654 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United States

Top matrices for ASTM D1654 in United States

Top analytes for ASTM D1654 in United States

  • Hardness1
  • Hexavalent Chromium1

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.