ISO 11608 Accredited Testing Labs in United States

ISO 11608, all parts: Needle-based injection systems for medical use - Requirements and test methods6 laboratories in United States are accredited by A2LA for at least one part of ISO 11608. Each lab card shows which parts it holds. From the accredited scope text: “ISO 11608-4 (Ed. 2); ISO 14708-1(Ed. 2, Ed. 1); ISO 14708-3 (Ed. 2, Ed. 1); ISO 14708-4 (Ed. 1) (All ISO 14708 standards exclude Cl.14.2 and Cl.22); ISO 80601-2-12 (Ed. 1, Ed. 2, Ed. 3); ISO 80601-2-5” “ISO 11608-1 Environmental Conditioning Free Fall Testing Vibration Testing Dose Accuracy Sharps Injury Protection – Requirements and Test Methods – Sharps Protection Features for Single-use Hypodermic” “ISO 11608-1 Temperature and Humidity Temperature Range: -45 C to 120 C Humidity Range: RH 10% to 95% ASTM F1980; ASTM F2825; ASTM D618; ASTM D4332 Distribution Testing ASTM D4169 Altitude ASTM D6653 D” “ISO 11608-1 (Section 11); CISPR 24 (2010+C1:2011+A1:2015, 2015) ; EN 50130-4; EN 55020”

Labs
6
Primary AB
A2LA6 labs
Parts of this series

Accredited Labs

Intertek Testing Services NA

Duluth, GA, US

HoldsPart 4
Scope

ISO 11608-4 (Ed. 2); ISO 14708-1(Ed. 2, Ed. 1); ISO 14708-3 (Ed. 2, Ed. 1); ISO 14708-4 (Ed. 1) (All ISO 14708 standards exclude Cl.14.2 and Cl.22); ISO 80601-2-12 (Ed. 1, Ed. 2, Ed. 3); ISO 80601-2-55 (Ed. 1, Ed. 2 + Am 1); ISO 8060

View lab

DDL, Inc. - DDL CA

Irvine, CA, US

HoldsPart 1
Scope

ISO 11608-1 Environmental Conditioning Free Fall Testing Vibration Testing Dose Accuracy Intravascular Catheters – Sterile and Single-use Catheters – Part 1: General Requirements ISO 10555-1 Corrosion Resistance Peak Tensi

View lab

DDL, Inc.

Eden Prairie, MN, US

HoldsPart 1
Scope

ISO 11608-1 Environmental Conditioning Free Fall Testing Vibration Testing Dose Accuracy Sharps Injury Protection – Requirements and Test Methods – Sharps Protection Features for Single-use Hypodermic Needles, Introducers for

View lab

TUV SUD America

San Diego, CA, US

HoldsPart 1
Scope

ISO 11608-1 (Section 11); CISPR 24 (2010+C1:2011+A1:2015, 2015) ; EN 50130-4; EN 55020

View lab

Eurofins Lancaster

Lancaster, PA, US

HoldsPart 1
Scope

ISO 11608-1 Cartridge Holder Removal Force of Pen- or Auto- Injectors (Axial Load) ISO 11608-1 Dose Accuracy of Pen- or Auto-Injectors ISO 11608-1 Drop Testing of Pen- or Auto-Injectors ISO 11608-1 Injection Force Activation for Pen-

View lab

DDL MN2

Minnetonka, MN, US

HoldsPart 1
Scope

ISO 11608-1 Temperature and Humidity Temperature Range: -45 C to 120 C Humidity Range: RH 10% to 95% ASTM F1980; ASTM F2825; ASTM D618; ASTM D4332 Distribution Testing ASTM D4169 Altitude ASTM D6653 Drops ASTM D5276

View lab
Refine these results

This page is a fixed slice of the register: every ISO 11608 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United States

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches