ISO 11997 Accredited Testing Labs in United States

ISO 11997, all parts: Paints and varnishes - Determination of resistance to cyclic corrosion conditions10 laboratories in United States are accredited by A2LA for at least one part of ISO 11997. We don't know yet whether 4 of them take outside work. Each lab card shows which parts it holds. From the accredited scope text: “ISO 11997-1 (Cycle B); LP-463PB-22-01 (Method II and IV); LP-463PB-52-01; MBN 10494-6 Section 5.4; NES M0007-33.4; PV1210; SAE J2334; SAE J1563 Section 10 figure 4; VDA 621-415 Filiform ASTM D2803; HE” “ISO 11997-2, SAE J2020, IEEE C57.12.31 (5.4.5) Cyclic Corrosion ASTM G85 Annex A1, A2, A5, SAE J2334, GMW 14872, ISO 9227, 11997-1, AAMA 2603 (8.7.2), 2604 (8.8.2), 2605 (8.8.2) Filiform Corrosion GMW” “ISO 11997-1; JIS Z 2371 IGC Sensitivity/ Resistance ISO 11846, ASTM G110 1 Test Methods developed and verified in house. 2Please note that this is not a test method but rather a heat treatment specifi” “ISO 11997-1; VDA 621-415L Humidity, Condensation/Water Fog ASTM D1735, D2247; DIN 50017; ISO 6270-2, 4628-3 Hydrogen Embrittlement ASTM F519 Salt Spray ASTM B117, D610, G85 (Except A4); DIN 50021; HES”

Labs
10
Primary AB
A2LA10 labs
Parts of this series

Accredited Labs

Durham Holdings Corporation dba MME Testing

Suwanee, GA, US

HoldsPart 1
Scope

ISO 11997-1, Cycle B; GMW14872; PV 1210; VDA 621-415 Degree of Blistering ASTM D714; ISO 4628-2 Degree of Rusting ASTM D610 Fluid Resistance via Immersion, Drip, and Pooling at Room or Elevated Temperature for Acids, Adhesiv

View lab

Michigan Testing Institute

Sterling Heights, MI, US

HoldsPart 1
Scope

ISO 11997-1; NISSAN NES M0158; NES M0007 (2014-1) (34); RIVIAN RTS.1681; SAE J2334; SAE J2721; TESLA TP-0000808, TP-0000588; TOYOTA TSH1555G (A); VOLKSWAGEN PV1210 VDA 233-102 Dead Load Seam Strength ASTM D751 (80-83) Detergen

View lab

Applied Technical Services

Marietta, GA, US

HoldsPart 1
Scope

ISO 11997 (Part 2, Part 5, Part 6) CASS ASTM B368 Filiform Corrosion ASTM D2803; DIN 3665 Neutral Salt Spray ASTM B117; DIN EN ISO 9227; DIN 50021; ISO 7253; MBN 10494 Temperature / Humidity MIL-STD-810H (Method 501, 502,

View lab

National Exposure Testing

Sylvania, OH, US

HoldsPart 1
Scope

ISO 11997-1 Cycles A-D; ISO 12944-6 Annex B; JASO M609; JASO M610; Navistar MPAPS GT-Paint GT-7D; NES M0007 Section 34; NES M0158, CCT-I; NES M0158, CCT-IV; Peugeot B21 7130 (Appendix 3); SAE J2334; Tesla TP-0000808 (Humidity Fog)

View lab

Assured Testing Services

Ridgway, PA, US

HoldsPart 2
Scope

ISO 11997-2 Cyclic Corrosion Resistance1 Temperature: Ambient to 70°C -70 to 190°C Relative Humidity: 30 to 100% CNH MTM0106; Delphi DX900115; Ford 00.00-L-467; Ford 00.00-L-3190; For

View lab

IMR Test Labs - Louisville

Louisville, KY, US

HoldsPart 1
Scope

ISO 11997-1; VDA 621-415L Humidity, Condensation/Water Fog ASTM D1735, D2247; DIN 50017; ISO 6270-2, 4628-3 Hydrogen Embrittlement ASTM F519 Salt Spray ASTM B117, D610, G85 (Except A4); DIN 50021; HES 6501; ISO 9227; MIL-STD 1312-1 (

View lab

Hydro Aluminum Technology Center (HATC)

Cassopolis, MI, US

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

ISO 11997-1; JIS Z 2371 IGC Sensitivity/ Resistance ISO 11846, ASTM G110 1 Test Methods developed and verified in house. 2Please note that this is not a test method but rather a heat treatment specification covering the pyrometric

View lab

PPG Industrial Electrocoat Performance

Springdale, PA, US

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

ISO 11997-1 (Cycle B); LP-463PB-22-01 (Method II and IV); LP-463PB-52-01; MBN 10494-6 Section 5.4; NES M0007-33.4; PV1210; SAE J2334; SAE J1563 Section 10 figure 4; VDA 621-415 Filiform ASTM D2803; HES D6501-3.16.1 Film Thickness

View lab

Protech Powder Coatings

STRONGSVILLE, OH, US

We don't know yet whether this lab takes outside work.
HoldsPart 2
Scope

ISO 11997-2, SAE J2020, IEEE C57.12.31 (5.4.5) Cyclic Corrosion ASTM G85 Annex A1, A2, A5, SAE J2334, GMW 14872, ISO 9227, 11997-1, AAMA 2603 (8.7.2), 2604 (8.8.2), 2605 (8.8.2) Filiform Corrosion GMW 15287, SAE J2635 Water Resistance

View lab

Robert Bosch

Plymouth, MI, US

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

ISO 11997-1 (2017); JIS Z 2371 (2015); GMW3172 (2010, 2012, 2014, 2015, 2018, 2023); TP-0000808 (Rev. 04 and 05); IEC 60068-2-52 (2017); CETP 00.-L-467-Ford; (2020); SAE J2334 (2003,2016); ESLX61-8C607-A2-CC (2015); BI 123-03 (Coo

View lab

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.