ISO 4892-3; SAE J2412
ISO 4892, all parts: Plastics - Methods of exposure to laboratory light sources11 laboratories in United States are accredited by A2LA for at least one part of ISO 4892. Each lab card shows which parts it holds. From the accredited scope text: “ISO 4892-1, WST stands for White Standard Temperature according to DIN EN ISO 4892- 1, BPT stands for Black Panel Temperature according to ASTM G179-04, and WPT stands for White Panel Temperature acco” “ISO 4892-3; SAE J2412” “ISO 4892-2 Exposure to Laboratory Light Sources – Xenon-arc Lamps ISO 4892-3 Exposure to Laboratory Light Sources – Fluorescent UV Lamps ISO 4892-4 Exposure to Laboratory Light Sources – Open Flame ca” “ISO 4892-2 Xenon Arc Ex posure ISO 20795-1 Dentistr y: Denture Base Polymers Microscope Manual Li ght Microscopy: Image Analysis, Light Microscope, Optical Microscopy MIL-STD-202-208 Solderabilit y of”
Wyoming, MI, US
ISO 4892-3; SAE J2412
Hillsboro, OR, US
ISO 4892-3; SAE J2020 Xenon Weathering Test MIL-STD-810 E, F, G, H Method 505; ISO 4892-2; SAE J1885 Protection Against Solid Foreign Objects IEC 60529 Sec. IP 1X, IP 2X, IP 3X, IP 4X, IP 5X, IP 6X Fluid Susceptibility RTCA
Sylvania, OH, US
ISO 4892-3; ISO 11507 (Method A); NES M0007 (Section 48 UV Method); SAE J2020 Filiform ASTM D2803 (Procedures A-C); HES D6501 (Section 3.16.1); IEC 60068-2-52; NES M0007 Section 35; Subaru TS312-01-051 Rating and Evaluation
Kentwood, MI, US
ISO 4892-3; ASTM D4329; ABYC H-31; ABYC S-31 Salt Spray/Humidity/CASS ASTM B117; ASTM B368; ASTM D1735; ASTM D2247; Chrysler LP-463PB-9-01; Chrysler LP-463PB-10-01; FLTM BI 103-01; FLTM EU BQ-005-02; GM 4298P, 4465P; SAE J575, J138
Miami, FL, US
ISO 4892-2 Exposure to Laboratory Light Sources – Xenon-arc Lamps ISO 4892-3 Exposure to Laboratory Light Sources – Fluorescent UV Lamps ISO 4892-4 Exposure to Laboratory Light Sources – Open Flame carbon-arc Lamps I
This page is a fixed slice of the register: every ISO 4892 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.
Search labs in United StatesAmerican Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.