ASTM E18 Accredited Testing Labs Worldwide
470 accredited laboratories in 23 countries hold ASTM E18 in their accredited scope. We don't know yet whether 192 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Italian Accreditation Body, United Kingdom Accreditation Service.
Available in 23 Countries
Sample labs
ASTM E18 Indirect Verification of Brinell Hardness Testers at Test Conditions 3 HBW 10/500/15 (HBW 217) HBW 10/1500/15 (HBW 186) HBW 10/3000/15 (HBW 230) 5.0 HBW 1.9 HBW 2.8 HBW Indirect ve
ASTM E18-20 Indirect Verification of Brinell Hardness Testers 3 HBW 2.5/62.5 HBW: Low High 1.7 HBW 2.4 HBW Indirect verification per ASTM E10-15a Rotational Speed, RPM 3 – Me
ASTM E18; GB/T 230.1 Vickers (1/5/10/30 kgf) ASTM E92, E384; GB/T 4340.1 Metallographic Evaluation Grain Size ASTM E112; GB/T 6394 Decarburization Depth (Metallographic Method Only) GB/T 224 Nonmetallic Inclusions (Method A Only) ASTM
ASTM E18 Vickers (5, 10 and 30 kgf) Vickers Micro-indentation (0.1, 0.3, 0.5 and 1.0 kgf) BS EN ISO 6507-1; ASTM E92, ASTM E384 Shore A & D ASTM D2240; ISO 868
ASTM E18 Standard Practice for General Techniques of Infrared Microanalysis ASTM E334 Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique ASTM F1057 Standard Practic
ASTM E18 using hardness test blocks Vickers Hardness Tester 3 (100 to 650) HV (650 to 940) HV 5 HV 2.5 HV Indirect Verification per ASTM E92 using hardness test blocks Mass Determination 1 g 100 g 200 g 500 g
ASTM E18 Microhardness (Vickers & Knoop) ASTM E384/E92 1 This laboratory performs field testing activities for these tests. 2 Lambda Research, Inc. in-house method. The laboratory is only accredited for the test methods lis
ASTM E18, ASTM F606/F606M; ISO 898-1 Microhardness (Vickers HV 500 gf) ASTM E384 Case Depth SAE J423, Paragraphs 4.2 and 5.3 Decarburization ASTM F2328; ISO 898-1 Tensile (Proof, Axial, Wedge Tensile) ASTM F606/F606M,
ASTM E18, E140 Brinell (500, 1500, 3000 Kg) ASTM E10 Mechanical Tensile (Room Temperature, Up to 200k lbs.) (Non-Ambient, -65 to +300 ºF, Up to 33,500 lbs.) ASTM A370, B557, E8/E8M ASTM E21 Compression
ASTM E18 Microhardness Knoop (100) gf ASTM E384 Vickers (100, 300, 500) gf, ASTM C1327, ASTM E384 Failure Analysis ASM Handbook 11
ASTM E18 TPA ATL
ASTM E18 Pressure – Measure & Measuring Equipment3 (3 to 60) psi (> 60 to 270) psi (> 500 to 1000) psi (> 1000 to 5000) psi (> 5000 to 9000) psi 0.41 psi 0.82 psi 7.7 psi 22 psi 23 psi Master pressure gage
ASTM E18 (ISO 6508-2); Standard blocks Direct Verification of Rockwell Hardness Testing Machine 3 – Verification of the Test Force Verification of the Measuring Device 98.07 N Preliminary test force
ASTM E18-22 Vickers (HV10 & HV30) BS EN ISO 6507-1:2023 ASTM E92-23 Corrosion Resistance to pitting corrosion ASTM G48-11(2020) (Method A) Inter-granular corrosion ASTM A262-15 Practice E(2021) ASTM G28- 22 Method
ASTM E18
ASTM E18 Indirect Verification of Rockwell & Rockwell Superficial Hardness Testers 3 – (cont) HR30TW: Low Medium High HR45TW: Low Medium High 1.9 HR30TW 2.0 HR30TW 1.8 HR30TW
ASTM E18, F606/F606M; MIL-STD 1312-6 (withdrawn 1997) Brinell (500 kg, 3000 kg) ASTM E10 Microhardness, Vickers and Knoop (100 to 500) g ASTM E384, E92 Tensile (to 300 klbs - Room Temperature): Axial & Wedge ASTM
ASTM E18, F606/F606M; ISO 898-2, 6508-1 ISO 898-2, 6507-1; ASTM E92 Microhardness – HV0.3 ASTM E384 Tensile Strength on Wire (Ultimate Strength, % Elongation, % RA) ASTM E8/E8M Proof Load – Internal Threads (Cone and A
ASTM E18-25 - escluso/except par 5.8 _ Durezza Vickers/Vickers hardness (HV5, HV10) Durezza Vickers/Vickers hardness (HV5, HV10) Esame macroscopico/Macroscopic examination Esame microscopico/Microscopic examination Frazione di volume
ASTM E18 hardness standards
ASTM E18, F606/F606M Average Grain Size (Comparison) ASTM E112 Microhardness (HK 0.1, 0.5; HV 0.1, 0.5) ASTM E92, E384 Fastener Tensile (Axial & Wedge) ASTM F606/F606M Inclusion Content ASTM E45 (Method A) SEM/EDS Analysis
ASTM E18, ASTM F606/F606M; ISO 6508-1, ISO 898-1 ASTM E92, ASTM E384, ASTM F606/F606M; ASME B18.6.3, ASME B18.6.5M; SAE J81, SAE J933, SAE J1237; ISO 898-1, ISO 6507-1 Tensile - External Thread Axial & Wedge, Proof Lo
ASTM E18, F606, F606M Microhardness (HV 300, 500g) (HK 300, 500g) ASTM B578, E384 Scanning Electron Microscopy (SEM) MM00051, ASTM B748 Tensile, Yield, Elongation, Reduction of Area ASTM A370, E8 (Room Temperature) LAP Shear AS
ASTM E18, ISO 6508-1, ISO 6508-2 VDM 5 Determination of weld defects in fillet welds; Fillet weld fracture test WI-C2 API 1104, ASME IX, AWS D1.1/D1.1M, AWS D1.2/D1.2M, AWS D1.6/D1.6M, ISO 9017 VDM 6 Determination of weld structur
ASTM E18 Indirect Verification of Brinell Hardness Testers at Test Conditions 10/3000/15 (100 to 199) HBW 6.6 HBW Indirect comparis
ASTM E18
ASTM E18, ASTM F606/F606M Brinell (10 mm ball, 3000 Kg load) ASTM E10 Pitting/Corrosion ASTM G48 - Method A Detecting Detrimental Intermetallic Phase ASTM A923 Methods A, B, and C Intergranular Attack in Ferritic Stainless Steels ASTM A
ASTM E18 & test blocks Vickers Hardness Testers3 < 402 HV (403 to 694) HV > 694 HV 12 HV 8.6 HV 14 HV Indirect verification per ASTM E92 & test blocks
ASTM E18
ASTM E18 / Matériaux métalliques Essai de dureté Brinell Dureté HBW 2,5/62,5 et HBW 2,5/187,5 NF EN ISO 6506-1 - 04/2006 (norme annulée) * NF EN ISO 6506-1 ASTM A370-02* ASTM A370 ASTM E10 / Matériaux métalliques Essai de dureté
ASTM E18 Indirect Verification of Brinell Hardness Testers3 HBW 10/3000/15 239 HBW 290 HBW 528 HBW 4.5 HBW 4.5 HBW 6 HBW Indirect verification per ASTM E10, ASTM E110 Mass - Fixed Points
ASTM E18 -24 2024 Standard Test Methods for Rockwell Hardness of Metallic Materials HE ASTM E384 -22 2022 Standard Test Method for Microindentation Hardness of Materials HE DIN 50159 -1 2022 -06 Metallische Werks
ASTM E18
ASTM E18 V. Thermodynamics Parameter/Equipment Range CMC2, 5, 8 (±) Comments Infrared Temperature Indicators 3 (Optical Pyrometers) @ 35 °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C
ASTM E18 2022 Standard Test Methods for Rockwell Hardness of Metallic Materials ASTM E92 2023 Standard Test Methods for Vickers Hardness of Metallic Materials ASTM E384 2022 Standard Test Method for Microindentation Hardness o
ASTM E18 Calibration of Force Gages, Load Cells, Dynamometers & Cable Tensiometers 3 Up to 200 lbf (0 to 500) lbf (0 to 1000) lbf (0 to 10 000) lbf 0.02 % + 0.6R 0.32 lbf + 0.6R 0.94 lbf + 0.6R
ASTM E18 Brinell – 3000 kgf ASTM E10 Vickers (100, 200, 300, 500,) gf Vickers (5, 10, 30) Kgf ASTM E384 ASTM E92 Impact – Charpy Method ASTM E23 Guided Bend Test for Ductility of Welds ASTM E190 Metallographic Evaluati
ASTM E18 Indirect Verification of Brinell Hardness Testers 3 215 HBW 232 HBW 1.9 HBW 4.9 HBW Indirect verification per ASTM E10 Indirect Verification of Leeb Reference Hardness Testers3 762 HLD 6 HLD Indire
ASTM E18-25 ASTM E92-23 ISO 6507-1:2023, UNI EN ISO 6507-1:2023 _ _ _ _ _ _ _ Esame macroscopico/Macroscopic examination Esame microscopico/Microscopic examination Frazione di volume mediante sistematico conteggio manuale di pun
ASTM E18:2024 Metallurgical tests Grain size determination ASTM E112:2024 Inclusion content ASTM E45:2018a Method A Stainless steels Determination of intergranular attack ASTM A262:2021 Practice A Corr
ASTM E18
ASTM E18; ISO 6508-1 Brinell (500, 3000) Kg ASTM E10 Vickers (100, 200, 300, 500, 1000) gf ASTM E92, E384 Knoop (100, 200, 300, 500, 1000) gf ASTM E92, E384 Impact (Charpy / (-320 to 450) oF) ASTM A370, E23; ISO 148-1
ASTM E18 Vickers ( HV10 and HV30) BS EN ISO 6507-1 ASTM E92 Vickers Micro-hardness (HV0.3, HV0.5 and HV1.0) BS EN ISO 6507-1 ASTM E384 Impact: Izod BS 131:Part 1 Charpy (V and U notches) (temperatures, -
ASTM E18-24 - escluso/except Par. 5.8 ASTM A370-24a - escluso/except durometri portatili Durezza Vickers/Vickers hardness (HV0,2 - HV0,5 - HV1 - HV5 - HV10) ASTM E92-23 Durezza Vickers/Vickers hardness (HV0,2 - HV0,5 - HV1 - HV5 - HV1
ASTM E18 ___________________________________________ 1 This laboratory offers commercial and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a la
ASTM E18 TPA ATL
ASTM E1820; BSI 7448; ISO 12135, ISO 15653 Nick-Break Test AWS B4.0 Hardness Rockwell (B, C) Vickers Macro Hardness (10 kg) ASTM E18, ASTM E140 ASTM E92 Vickers Micro Hardness (100, 200,
ASTM E18
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AGM CON-TEST 116 Viceroy Road Building C, Units 11-12 Concord, Ontario, Canada L4K 2M3 Lyudmyla Boyko Phone: 905 760 9322 MECHANICAL Valid To: July 31, 2028
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FASTENAL COMPANY LABORATORY - SHANGHAI Plant B, Building A5, No.3802 Shengang Road, Songjiang District, Shanghai, People’s Republic of China
Showing labs 101–150 of 470. Use pagination below to see more.