ASTM E83 Accredited Testing Labs Worldwide
30 accredited laboratories in 4 countries hold ASTM E83 in their accredited scope. We don't know yet whether 6 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Comité français d'accréditation.
Available in 4 Countries
Sample labs
ASTM E83, ISO 9513 Glass scale, digital calipers Linear incremental scale Magnetic scale (Class C) Linear encoder US MX
ASTM E83 & ISO 9513; Gage blocks, extensometer calibrator; uncertainties listed in displacement Gage blocks Caliper Micrometers³ – Up to 6 in (> 6 to 20) in (71 + 0.6R) µin (200 + 0.6R) µin Gage b
ASTM E83 II. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Force3 – Measure Tension 0.022 lbf (10 gf) 0.0551 lbf (25 gf) 0.11 lbf (50 gf) 0.22 lbf (100 gf) (1 to 9) lbf
ASTM E83, ISO 9513 Digital caliper Heidenhain glass scale Displacement 3 – Measure (0.001 to 1.0) in (1.0 to 40) in 0.000 062 in 0.0017 in ASTM E 2309 Heidenhain length gages Morehouse reado
ASTM E83 with: Precision micrometer Gauge block set Caliper Digital encoder
ASTM E83, ASTM E399, E1820 Caliper ASTM E2309 Digital indicator Dial indicator Cable transducer ASTM E2658 cable extension transducer and stopwatch
ASTM E83, ISO 9513 ASTM E2309 Using precision micrometer system or linear precision scale Gage blocks Testing Machine Crosshead Speed 3 – Measure Displacement Time (0.002 to 50) in/min --
ASTM E83 Gauge Length Up to 300 mm (300 to 600) mm 0.07 mm 1 mm BS EN ISO 9513 & ASTM E83 Micrometer External Length3 Up to 25 mm 2.0 µm JIS B 7502
ASTM E83 ASTM E399 Material Testing System Crosshead Displacement or Actuator Stroke3 Up to 24 in 0.001 in Method: ACP-052; ASTM E2309/E2309M Material Testing System Crosshead/Actuator Speed 3 12 in/min
ASTM E83, calibrator, gage blocks Caliper Calibration of Stage Micrometers Up to 10 mm 3.5 µm Non-contact 2 axis CMM (vision system)
ASTM E83 Principaux moyens utilisés : Banc micrométrique et capteurs de déplacement Sur site Portée flexible FLEX1 : le laboratoire est reconnu compétent pour pratiquer les méthodes référencées et leurs révisions ultérieures. (*)
ASTM E83: Micrometer head Calipers Linear Displacement 3 – Measure (0.1 to 1) in (0.25 to 25) in (0.25 to 50) in 0.000 52 in 0.031 in 0.036 in ASTM E2309: Digital indicator Linear encoder
ASTM E83 w/ calibrated scale Rubber Hardness – Block Standardization: Shore A Shore C Shore D Shore M IRHD M (0 to 100) units (0 to 100) units (0 to 100) units (0 to 100) units (0 to 100) units
ASTM E83 Principaux moyens utilisés : Banc micrométrique Sur site Portée flexible FLEX1 : Le laboratoire est reconnu compétent pour pratiquer les méthodes référencées et leurs révisions ultérieures .
ASTM E83, ISO 9513 using digital high accuracy length scale Scales & Balances 3 (0.01 to 1000) lbf 4.5 g to 454 kg 0.01 % + 0.6R Master dead weights ASTM E898 Torque 3 – Measuring Equipment (0.1 to 150) lbf∙ft
ASTM E83, E399, ISO 9513 Extensometer calibrator Laser interferometer Extensometer calibrator (excluding ASTM E399) Optical & extensometer calibrator Caliper North America, Japan Norden North
ASTM E83-16 parts 4; 5 7; 8. Torque Wrenches 4 lbfꞏin to 600 lbfꞏft 0.79 % rdg ASME B107.300 Pressure Gages (0 to 6) psig (>6 to 30) psig (>30 to 100) psig (>100 to 500) psig (>500 to 1000) psig (>1000 to 5000
ASTM E83, calibrated bar ASTM E83 using caliper Digital position kit Digital speed/position kit Load cell & die Calculated from force to pressure Scales & Balances 3 (1 to 10) g (>10 to 220) g (>220 to 500) g
ASTM E83 ASTM E2309 / Sur site Extensomètres Dispositifs d'allongement Longueur Vérification d’extensomètre par variation de longueur, comparaison à une chaine de mesure de déplacement (banc micrométrique) Méthode interne n° MET-FO
ASTM E83 Calipers3 Up to 6 in Up to 12 in Up to 48 in 300 µin 320 µin 760 µin Gage blocks, length bar
ASTM E83, Class 2 gage blocks, steel rule Steel rule Stopwatch Vacuum Gauges3 (0 to 24) in·Hg 0.64 in·Hg ASME B40.1.91, vacuum gage
ASTM E83 Displacement Measurement System3 (0.05 to 8) in 170 μin Digital indicator (w/ guage blocks) ASTM E2309
ASTM E83 w/ micrometer heads Calipers and outside micrometers Epsilon 3590 VHR ASTM E2309- 2309M w/ dial indicator
Parameter/Equipment Range CMC2 (±) Comments Radius gauges Up to 150 mm 0.028 mm Measuring microscope Gauge of Punches Up to 200 mm 0.004 mm Gauge blocks Surface of hole / Chamfers -
ASTM E83
ASTM E83 ASTM E399 Principaux moyens : banc micrométrique et capteurs de déplacement Sur site Machines de dureté BRINELL Dureté Vérification globale de la machine de dureté par Méthode indirecte NF EN ISO 6506-2 ASTM E10 Prin
ASTM E83, ISO 9513 using a model 3590 calibration test stand II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure (0 to 50) mV (0 to 10) V 0.0087 mV
ASTM E83 / Traverses ou vérins Longueur, temps Vérification de la vitesse de déplacement à l'aide d’un comparateur dimensionnel différentiel numérique et chronomètre ASTM E2658 / Capteurs d’ouverture Longueur Vérification de la linéar
ASTM E83 NF EN ISO 527-1 - Annexe C Principaux moyens utilisés : Pied à coulisse Capteur de déplacement Banc micrométrique Sur site Capteurs d’ouverture Linéarité Vérification des capteurs d’ouverture pour essais K1c ASTM E399 Pri
ASTM E83 w/ Class B1, B2, C, D, & E; ISO 9513 w/ Class 0.5, 1, 2, 3 Using CAL 60 Using CAL 60 or long travel rig Using short travel rig or CAL 60 Using short travel rig or CAL 60 Direc