EN 301-489-20 Accredited Testing Labs Worldwide
30 accredited laboratories in 7 countries hold EN 301-489-20 in their accredited scope. We don't know yet whether 5 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.
Available in 7 Countries
Sample labs
STANDARD 2,3: DESCRIPTION OF STANDARD: FREMONT EN 301 489-12 EN 301 489-12 v3.2.1 EN 301 489-12 v3.1.1 ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 12: Specific conditions for Very Small Aperture T
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK TUV SUD Limited (Trading as TÜV SÜD) Issue No:
Test: Test Methods1: EU Radio Standards (continued) EN 302 208; EN 302 574-3; EN 303 345-1; EN 303 345-3; EN 303 413; EN 303 417; ETSI EN 303 687 Sound System Equipment BS EN/EN 50332-1; BS EN/EN 50332-2 EU EMC Standards E
Test Technology: Test Method(s)1: Product Standards (Cont.) Generic Emissions for Industrial Environments IEC 61000-6-4; EN 61000-6-4; AS/NZS 61000.6.4; KS C 9610-6-4 Maritime navigation and radiocommunication equipment and
Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkung zum Prüfverfahren Funk ETSI EN 301 489-19 V2.1.1 ElectroMagnetic Compatibility (EMC) standard for radio equipment and serv
Test Technology: Test Method(s)1: Voltage Dips and Interrupts IEC 61000-4-11;EN 61000-4-11; BS EN 61000-4-11; AS/NZS 61000.4.11 Product Family and Industry Specific Standards CISPR 35; EN 55035; BS EN 55035; AS/NZS CISPR 35;
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung EMV ETSI EN 301 489 -9 V2.1.1 (2019-04) Electromagnetic Compatibility (EMV) standard for radio equipment and services; P
Test: Test Method(s) 1: Automotive EMC Radiated & Conducted Emissions CISPR 25 (sections 6.3, 6.4, 6.5 only); UNECE Regulation 10, Revision 6, Electronic Sub-assemblies (ESA), Sections 6.5, 6.6, 7.10 Radiated Immunity (ALSE) ISO
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV ETSI EN 301 489 -17 V3.3.1 (2024-09) ElectroMagnetic Compatibility (EMC) standard for radio equipment an
Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV / EMC EN 301 489-16 V1.2.1:2002-08 Electromagn
Test: Test Methods: U-NII without DFS Intentional Radiators (AC Conducted Emissions Only) 47 CFR FCC Part 15, Subpart E (U-NII without DFS), (using ANSI C63.10-2013 and ANSI C63.10-2020); ANSI C63.10-2020/COR 1-2023); ANSI C63.10-
Test Technology: Test Method(s)2: Generic/Product Family/ Product Specific Standards (continued) ETSI TS 136 113; 3GPP TS 36.113; ETSI TS 137 113; 3GPP TS 37.113; ETSI TS 138 113; 3GPP TS 38.113; ETSI TS 138 114; 3GPP TS 38.11
Normative document: EN ISO/IEC 17025:2017 Registration number: L 022 of DEKRA Certification B.V. This annex is valid from: 18-06-2026 to 01-05-2030 Replaces annex dated: 08-01-2026 Dutch Accreditation Council RvA Page 37
18855 Adams Court Building AM1, AM2 Morgan Hill, CA 95037 Test Technology: Test Method(s): Emissions Radiated and Conducted (3m semi-anechoic chambers) CFR 47 FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47 FCC Part 18 (
Test Description: Test Method 2: Low Frequency Conducted Disturbance IEC 61000-4-16; EN 61000-4-16 Automotive (Generic) UNECE REG 10; EU 2015/208:2018 AUTOMOTIVE Electrostatic Discharge (ESD) ISO 10605; SAE J1113-13 Conducted E
Test Technology: Test Method(s)2,3: Radio Tests (cont.) Europe/ETSI ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETIS EN 300 330; ETSI EN 300 328; ETSI EN 300 440; ETSI EN 3
Test Technology: Test Method(s): Radiated Immunity IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; AS/NZS IEC 61000.4.3 Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHENZHEN HUAK TESTING TECHNOLOGY CO., LTD. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park Heping, Fuhai Street, Bao'an District Shenzhen, 518000, People’s Republic of Chin
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical field Standard / In-house procedure / Version Title of standard or in house procedure (deviations / mod
(A2LA Certificate No. 4201.01) Revised 06/25/2026 Page 6 of 12 Test Technology: Test Methods(s) 1,2: Australia / New Zealand (cont.) Radiocommunications (121.5 MHz and 243.0 MHz Emergency Position Indicating Radio Beacons) Standard 20
(A2LA Cert No. 4267.01) REVISED 06/30/2026 Page 3 of 14 Test Technology: Test Method(s)1: Multimedia Equipment (Excluding outdoor units of home satellite receiving systems and TV) CISPR 35; EN 55035; BS EN 55035; SASO CISPR
T290/A21/2025 Liite 1 / Appendix 1 Sivu / Page 4(24) Vaatimus/Requirement SFS-EN ISO/IEC 17025:2017 30.10.2025 Päätöksen päiväys / Date of decision 31.12.2029 Päätöksen viimeinen voimassaolopäivä / Date of expiry www.finas.fi Voimassaoleva
Test Technology: Test Method(s) 1: SAR/RF Exposure (cont.) EN 50385; EN 50364; EN 50663; EN 50665; IEEE C95.3; IEEE Std C95.1; IEC 63170, IEC 63195-1 AS/NZS 2772.1; AS/NZS 2772.2; ARPANSA Radiation Protection Series S-1 (Rev. 1)
Test(s): Test Method(s)1: Generic Family, Product, or Industry Specific Specifications (continued) EN 50270; EN 50270:2015/AC:2016-08 EN 301 489-1; ETSI EN 301 489-1 V2.2.3 (2019-11); KS X 3124; SANS 301489-1; EN 301 489-3; ETSI EN 30
Test Technology: Test Method(s) 1,2: Immunity Generic Product Family Standards (cont.) EN 61547; IEC/EN 60730-1 (Sections 23 & 26); IEC/EN 60730-2-9 (Sections 23 & 26)
European Union (EU) (cont’d) ETSI EN 301 489-17 v2.1.1; ETSI EN 301 489-17 v2.2.1; ETSI EN 301 489-17 v3.1.1; ETSI EN 301 489-17 v3.2.4; ETSI EN 301 489-17 v3.3.1; ETSI EN 301 489-17; ETSI EN 301 489-19 v2.2.1; ETSI EN 301 48
Test: Test Method(s)1: Immunity (continued) Power Frequency Magnetic Field Immunity (excluding short duration mode) IEC/EN 61000-4-8; AS/NZS 61000.4.8 Voltage Dips, Short Interruptions, and Line Voltage Variations IEC/EN 6
Test Technology: Test Method(s) 1: Immunity Electrostatic Discharge (ESD) EN 61000-4-2; IEC 61000-4-2; GB/T 17626.2; AS/NZS 61000.4.2; CNS 14676-2 Radiated Immunity (up to 18 GHz, 200 V/m) EN 61000-4-3; IEC 61000-4-3; GB/T 1762
EN 301-489-20; ETSI EN 301 489-34; ETSI EN 301 489-52 Bluetooth Bluetooth Radio and Protocol Conformance Testing: RF:1; RF-PHY1; RF-PHY2; RF-PHY3; Host Layers; Traditional Profiles and Protocols; GATT-Based Profile & Service:1;
Test Technology: Test Method(s) 1: Product Family Standards and Industry Specific Standards EN 50121-1; BS EN 50121-1; EN 50121-2; BS EN 50121-2; EN 50121-3-1; EN 50121-3-2; EN 50155; EN 55014-2; BS EN 55014-2; IEC/CISPR 14-2; AS/N