Registers refreshed 2026-11-20.See refresh dates

IEC 60068-2-14 Accredited Testing Labs Worldwide

292 accredited laboratories in 18 countries hold IEC 60068-2-14 in their accredited scope. We don't know yet whether 158 of them take outside work. Primary accreditors include Deutsche Akkreditierungsstelle, American Association for Laboratory Accreditation, United Kingdom Accreditation Service.

Total labs
292
Countries
18

Available in 18 Countries

Germany
133 labs
United States
26 labs
China
25 labs
United Kingdom
22 labs
Poland
18 labs
Italy
13 labs
Spain
12 labs
Canada
7 labs
Mexico
7 labs
France
5 labs
Netherlands
4 labs
Sweden
3 labs
Finland
3 labs
Taiwan
3 labs
Australia
2 labs
Japan
2 labs
Thailand
2 labs
Ireland
1 lab

Sample labs

Phoenix Contact GmbH & Co. KG Laboratory Industrial Cabinet Connectivity
Blomberg, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14: 2009-01 Umgebungseinflüsse – Teil 2-14: Prüfverfahren – Prüfung N: Temperaturwechsel Environmental testing – Part 2-14: Tests – test N: Change of temperature Außer Prüfung nach Abs. 9 Prüfung Nc Zwei Bäder- Me

Siemens Aktiengesellschaft SIMATIC Type Test Karlsruhe
Karlsruhe, DE
We don't know yet whether this lab takes outside work.

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Umweltprüfungen DIN EN 60068 -2- 1:2008-01 Umgebungseinflüsse − Teil 2 -1: Prüfverfahren − Prüfung A: Käl

Intercable Automotive Solutions Srl Brunico
Brunico, IT
We don't know yet whether this lab takes outside work.

Intercable Automotive Solutions Srl Brunico UNI CEI EN ISO/IEC 17025:2018 Allegato al certificato di accreditamento n. 02096 rev. 1 del 23/01/2025 Via Campi della Rienza 21 39031 Brunico BZ Revisione: 1 Sede A Data: 23/01/2025 p

Continental Autonomous Mobility Philippines
Calamba City, PH
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 Na; ISO 16750-4 (Section 5.3.2) IEC 60068-2-11; ISO 16750-4 (Section 5.5.2) IEC 60068-2-27; ISO 16750-3 IEC 60068-2-31 (Section 5.2 Free Fall – Procedure 1) IEC 60068-2-64, 60068-2-6; ISO 16750-3

KFE Kompetenzzentrum Fahrzeug Elektronik
Lippstadt, DE
We don't know yet whether this lab takes outside work.

Bereich Norm/ Prüfverfahren/Version Titel des Standards oder Prüfverfahrens Prüfbereich/ Einschränkung 2 Standort: Ostenfeldmark 2, 59557 Lippstadt 2.1 Elektrotechnik / Umweltsimulationsprüfungen Umwelt DIN EN 60068-2-1: 2008-01 Um

ZF Global Electronics - Validation
Farmington Hills, MI, US
We don't know yet whether this lab takes outside work.

IEC 60068-2-14; SAE J1455; CS-11982; DC-10611; 9.90111/02; CS-00056; ES-5F9T-14A626-AA; ES-BT4T-13D061-AA; CETP00.00-E-412; GMW 3172; TSC7000G; TSC0511G; 7796Z-FC0T-P000; 7794Z-T5A-J810-M1; 9.90110; ES 95400-10; ES95910-93; M

ZF Global Electronics - Czestochowa Engineering Center - Validation
Czestochowa, PL
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 Thermal Shock (-70 to 200 [+/- 2.0]) °C IEC 60068-2-14; PF-9688; PF-8982; CS-11982; DC-10611; ES-DG9T-14B522-AB; ES-5F9T-14A626-AA; ES-BT4T-13D061-AA; GM 9110P; TSC7000G; 7794Z_S3V_0000; 7794Z_TR0A_0000; 7794Z

Motorola Penang Product Quality And Reliability Engineering
Penang, MY
We don't know yet whether this lab takes outside work.

IEC 60068-2-14; IEC 60945 Section 8.5; EN 300 019-1-7; EN 300 019-1-5; GJB 150.5; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3 Rain and Spray MIL-STD-810 Method 506; IEC 60945 Section 8.8; GJB 150.8; NEMA 250 Section 5.7 Humidit

Preh GmbH
Bad Neustadt a.d. Saale, DE
We don't know yet whether this lab takes outside work.

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV 31850329 Rev. 004 (2014-06) EMC SYSTEM REQUIREMENTS Electromagnetic Compatibility Specification Withou

Visteon de Mexico S. de R.L.
Queretaro, Qro, MX
We don't know yet whether this lab takes outside work.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 VISTEON DE MEXICO S. DE R.L. Av. 5 de Febrero 1412A Interior 1 Colonia San Pablo CP 76159 Querétaro Qro, México Mr. Erick Cobian Phone: +52-614-429-5111 ecobian@visteon.com

EDAG Engineering GmbH ATC Fulda
Petersberg, DE
We don't know yet whether this lab takes outside work.

VW TL 226 2020-10 2018-04 2016-10 2013-08 Lackierungen auf Werkstoffen der Fahrzeug -Innenausstattung . VW TL 52726 2023-11 Kunststoffhochglanzanwendungen im Exterieurbereich . Anforderungen an die Oberfläche. 6 Umwelts

k3 works
Treuchtlingen, DE
We don't know yet whether this lab takes outside work.

Prüfungen in den Bereichen: mechanisch-technologische Prüfungen, Umweltsimulationsprüfungen und Permeationsmessungen (SHED) an technischen Produkten aus Kunststoff und Metall Dem Prüflaboratorium ist es gestattet, die mit *** gekenn

FAKT-GmbH Kraftfahrtechnisches Prüf- und Ingenieurzentrum
Heimertingen, DE
We don't know yet whether this lab takes outside work.

2. Umweltprüfungen von Systemen, Bauteilen und selbständigen technisches Einheiten für Fahrzeuge (A) DIN EN 60068 -2-1 2008-01 Umgebungseinflüsse - Teil 2-1: Prüfverfahren - Prüfung A: Kälte DIN EN 60068 -2-2 2008-05 Umgeb

Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Warszawa, PL
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2024-04 Odporność na wnikanie ciał stałych, pyłu i wilgoci do IP 68 PN-EN 60529:2003 PN-EN 60529:2003/A2:2014-07 Z wyłączeniem stopnia ochrony IP X9 (pkt 14) Wyroby elektrotechniczne Badanie rozżarzonym drutem PN-E

Panasonic Automotive Systems Europe GmbH Reliability
Langen, DE
We don't know yet whether this lab takes outside work.

verwendete Abkürzungen: siehe letzte Seite Die Urkunde samt Urkundenanlage gibt den Stand zum Zeitpunkt des Ausstellungsdatums wieder. Der jeweils aktuelle Stand des Geltungsbereiches der Akkreditierung ist der Datenbank akkreditierter

Politechnika Świętokrzyska
Kielce, PL
We don't know yet whether this lab takes outside work.

Laboratorium Elektrotechniki Pojazdowej Al. Tysiąclecia Państwa Polskiego 7; 25-314 Kielce Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Złącza instalacji elektrycznej Siły łączenia styków Wytrz

Brehmer GmbH & Co. KG
Nümbrecht, DE
We don't know yet whether this lab takes outside work.

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Test methods: DIN EN 60068 -2-1 2008-01 Environmental testing - Part 2-1: Tests - Test A: Cold DIN EN 60

Testing Center of United Automotive Electronic Systems Co.,
Pudong, Shanghai, CN
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 (excluding clause 9 Test NC: Rapid change of temperature two-fluid-bath method) Damp Heat, Cyclic IEC 60068-2-30 Salt Mist IEC 60068-2-11; ISO 9227 Human Exposure to Magnetic Field CNIRP; GB8702; GB/T 37130

ams-OSRAM International GmbH Reliability and Failure Analysis
Regensburg, DE
We don't know yet whether this lab takes outside work.

Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung Umwelt - simulation DIN EN 60068 -2-14: 2010 Umgebu

ASAP Engineering
Weyhausen, DE
We don't know yet whether this lab takes outside work.

Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist, ohne dass es einer vorher igen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormt en oder ihnen gleichzusetzenden Prüfverfahren mit untersc

Testing and Certification Center of Tianjin ENNEW Sensing Technology Co.,
Tianjin, CN
We don't know yet whether this lab takes outside work.

IEC 60068-2-14; EN IEC 60068-2-14; GB/T 2423.1; GB/T 2423.2; GB/T 2423.22 Damp Heat IEC 60068-2-78; EN 60068-2-78; BS EN 60068-2-78; IEC 60068-2-30; EN 60068-2-30; BS EN 60068-2-30; GB/T 2423.3; GB/T 2423.4

IMAT (Shenyang) Automotive Technologiy Co.,
CN
We don't know yet whether this lab takes outside work.

2 Environmental tests with temperature, humidity, solar simulation and in combination (qualification tests) on pre- and end-products as well as automobile industry components [Flex B] UNE -EN IEC 60068 -2-14 2023 -11 Environmental t

ZF Global Electronics - Eurofren Investment Mexico - Validation
Guadalupe, Neuvo Leon, MX
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 Temperature Tests (-55 to 135) °C ISO 16750-4; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14 Humidity Tests (20 to 95) %RH ISO 16750-4; IEC 60068-2-30; IEC 60068-2-38; IEC 60068-2-56; IEC 60068-2-78 Vibration w

Gentherm Investment (Shanghai) Co.,
Pudong New Area, Shanghai, CN
We don't know yet whether this lab takes outside work.

IEC 60068-2-14, -30, -38, -78; Hyundai ES-95400-10 (Sections 6.3.5, 6.3.6, 6.3.8); GMW 3172 (Sections 6.1, 9.4.3, 9.4.5); Mazda MES PW 67601 (Sections 7.2.5, 7.2.8, 7.2.11); Toyota TSC7000G (Sections 4.1, 4.7, 4.8); Toyota TSC7019G (Se

Deutsche Gesetzliche Unfallversicherung e.V. (DGUV) DGUV Test, Prüf- und Zertifizierungsstelle Elektrotechnik Fachbereich Energie, Textil, Elektro und Medienerzeugnisse
Köln, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2009-01 EN 60068-2-14:2009-07 DIN EN 60068-2-14 (VDE 0468-2-14):2010-04 Umgebungseinflüsse - Teil 2-14: Prüfverfahren - Prüfung N: Temperaturwechsel Environmental testing - Part 2-14: Tests - Test N: Change of tem

SIAC Test
Johnson City, TN, US
We don't know yet whether this lab takes outside work.

IEC 60068-2-14, Test Na

AERA Consulting & Engineering Gesellschaft für Umweltmeßtechnik mbH
Mühlhausen, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2009); Deutsche Fassung EN 60068-2-14:2009 Ohne Kapitel: 9, Prüfung Nc DIN EN 60068-2-27; 2010-02 (VDE 0468-2-27) Prüfung Ea und Leitfaden: Schocken (IEC 60068-2-27:2008); Deutsche Fassung EN 60068-2-27:2009 DIN

Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Warszawa, PL
We don't know yet whether this lab takes outside work.

Przedmiot badań/wyrób Material/product tested Rodzaj działalności/badane cechy/metoda Type of activity/parameter/ characteristic tested Dokumenty odniesienia Reference documents Wyroby elektryczne, Oprogramowanie, Wyroby i materiał

Kostal of America Test
Troy, MI, US
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 IEC 60068-2-30 IEC 60068-2-70 USCAR-21 SAE J1211 Force* (0.05 to 500) N22 PF11109 SAE USCAR 2 Torque* 0.05 Ncm to 3 Nm3 PF 11109 Vibration (Sine, Random, and Shock) Temperature/Humidity Using AGR

LABCO
Loxstedt-Stotel, DE
We don't know yet whether this lab takes outside work.

VDA 233-102 2013-06 Zyklische Korrosionsprüfung von Werkstoffen und Bauteilen im Automobilbau VDA 621-415 1982-02 Prüfung des Korrosionsschutzes von Kraftfahrzeuglackierungen bei zyklisch wechselnder Beanspruchung (zurückgezogene

Materialforschungs- und -prüfanstalt an der Bauhaus-Universität Weimar
Weimar, DE
We don't know yet whether this lab takes outside work.

DIN EN 60068 -2-6; VDE 0468-2-6 2008-10 Umweltprüfungen – Teil 2-6: Prüfungen – Prüfung Fc: Schwingen, sinusförmig DIN EN 60068 -2-13 2000-02 Umweltprüfungen – Teil 2: Prüfungen – Prüfgruppe M: Niedriger Luftdruck DIN EN 600

Jiaxing Hella Lighting Co.,
CN
We don't know yet whether this lab takes outside work.

K DAkkS Deutsche Akkreditierungsstelle Department Standard / In house procedure / Version Title of standard or in house procedure (Deviations / Modifications of standard) Test area / Reductions Location Location A: No. 1188 Kaixi Road, Jiax

APL Automobil-Prüftechnik Landau
Landau, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2009); German version EN 60068-2-14:2009 DIN EN 60068-2-30 2006-06 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h +12 h) (IEC 60068-2-30:2005); German version EN 60068-2-30:2005 DIN EN

BCS Automotive Interface Solutions Italy
Nichelino, IT
We don't know yet whether this lab takes outside work.

BCS Automotive Interface Solutions Italy s.r.l. UNI CEI EN ISO/IEC 17025:2018 Allegato al certificato di accreditamento n. 01346 rev. 5 del 19/12/2025 Via Miraflores 20 10042 Nichelino TO Revisione: 11 Sede A Data: 19/12/2025 pa

Xiamen Hongfa Transportation Electronics Co., Ltd Technical Center
CN
We don't know yet whether this lab takes outside work.

IEC 60068-2-14: 2009-01 Environmental testing - Part 2-14: Tests - Test N: Change of temperature; Only Perform: Na, Nb Environmental testing DIN EN 60068-2-14: 2010-04 Environmental testing - Part 2-14: Tests - Test N: Change of

SIGNAL CERT
Katowice, PL
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2024-04 Elementy i urządzenia mechaniczne oraz mechaniczno- elektryczne Siła Zakres: 15 kN, 100 kN Procedura LB-1.07 wersja 3.01 z 06.06.2024 r. Wersja strony: A

Bertrandt Ingenieurbüro
Köln, DE
We don't know yet whether this lab takes outside work.

Prüfungen in den Bereichen: Temperatur, Feuchte, Sonnenstrahlung, Infrarotbestrahlung, Betriebsfestigkeit, Vibration und mechanischer Stoß sowie in deren Kombination Umweltsimulationsprüfungen (Qualifikationsprü- fungen) an technischen Pr

UK Grid Solutions
Stafford, GB
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2009:N IEC 60068-2-14:2023: Test N Test Nb: Change of temperature with specified rate of change Max temp: +85oC Min temp: -40oC Max rate 1oC/min Max chamber size: 970 mm x 970 mm x 1050 mm Real time dig

Magna Electronics
Southfield, MI, US
We don't know yet whether this lab takes outside work.

IEC 60068-2-14; ISO 16750-4

Vitesco Technologies GmbH EMOB R&D T&V ENT NUE
Nürnberg, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14: 2023-7 Environmental testing – Part 2-14: Tests – Test N: Change of temperature Without Prüfung Nc; Umwelt- simulation DIN EN IEC 60068-2-14: 2025-03 VDE 0468-2-14: 2025-03 Umgebungseinflüsse – Teil 2-14: Prüf

Siemens Aktiengesellschaft AG SI EP EMS R&D TC3
Amberg, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14 Edition 6.0, 2009-01 Environmental testing – Part 2-14: Tests Test N: Change of temperature Only test Na , Nb EN 60068-2-14 2009-07 Environmental testing – Part 2-14: Tests Test N: Change of temperature Only test

iwis mobility systems GmbH & Co. KG iTC - iwis Test Center iwis Werk München
München, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14: 2023-7 Environmental testing – Part 2-14: Tests – Test N: Change of temperature Without Prüfung Nc; Umwelt- simulation DIN EN IEC 60068-2-14: 2025-03 VDE 0468-2-14: 2025-03 Umgebungseinflüsse – Teil 2-14: Prüf

HIMA Paul Hildebrandt GmbH Abteilung EDS, Team TLab
Brühl, DE
We don't know yet whether this lab takes outside work.

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Testing field Standard / in house procedure / Version Title of standard or in house procedure Test range / r

Siemens Aktiengesellschaft SIMATIC TYPE Test Amberg
Amberg, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14: 2023) Umweltprüfungen - Teil 2: Prüfungen; Prüfung N : Temperaturwechsel (IEC 60068-2-14:2023) Ohne Prüfung Na, Nc Umwelt - prüfungen IEC 60068 -2-27 :2008 Environmental testing – Part 2-27: Tests – Test E

Keysight Technologies Deutschland GmbH Hardware Test Center Europe
Böblingen, DE
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature Umwelt- Simulation DIN EN 60068-2-27:2010 VDE 0468-2-27:2010 EN 60068-2-27:2009 Umgebungseinflüsse - Teil 2-27: Prüfverfahren - Prüfung

Leonardo UK
Edinburgh, GB
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:1984 Two chamber method BS EN 60068-2-14:2000 BS EN 60068-2-14:2009 MIL-STD-810B, 503 Max temp: +80°C MIL-STD-810C, 503.1 MIL-STD-810D, 503.2 Min temp: -60°C MIL-STD-810E, 503.3 Max chamber size: 1 m x 1 m

Faurecia R&D Center
Grójec, PL
We don't know yet whether this lab takes outside work.

Przedmiot badań/wyrób Product tested/material Rodzaj działalności/ badane cechy/metoda Type of test/properties measured/method Dokumenty odniesienia Reference documents Siedzenia, Elementy siedzeń, Wyposażenie wewnętrzne po

Pilz GmbH & Co. KG
Ostfildern, DE
We don't know yet whether this lab takes outside work.

Bereich Norm/ Hausverfahren/ Version Titel der Norm Prüfbereich / Einschränkungen 3.1 Grundnormen Umwelt IEC 60068 -2-1:2007 -03 Environmental testing - Part 2 -1: Tests - Test A: Cold Bis max. -50 °C Umwelt DIN EN 60068 -2-1:

Jordan Design and Development Bureau
Jordan, JO
We don't know yet whether this lab takes outside work.

IEC 60068-2-14:2023 Test Na MIL STD 810H Method 503.7 ISO 16750-4:2023 ISO 16750-4:2012 Clauses 5.2, 5.3.1 HUMIDITY TESTS Temperature from -40°C to +150°C Humidity from 10 to 98 % rh IEC 60068-2-30 2005 Test Db IEC 60

DIXI MICROTECHNIQUES
MARCHAUX-CHAUDEFONTAINE, FR
We don't know yet whether this lab takes outside work.

Equipements industriels et produits d’ingénierie / Tout équipement et produit (industriel et de consommation) soumis à des essais en environnement climatique et mécanique / Essais en environnement climatique (38) Référence portée généra

Showing labs 151–200 of 292. Use pagination below to see more.