Registers refreshed 2026-11-20.See refresh dates

IEC 61215 Accredited Testing Labs Worldwide

IEC 61215, all parts. Each lab card shows which parts it holds.

30 accredited laboratories in 9 countries hold IEC 61215 in their accredited scope. We don't know yet whether 7 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Entidad Nacional de Acreditación.

Total labs
30
Countries
9

Available in 9 Countries

United States
10 labs
Germany
5 labs
Spain
5 labs
China
3 labs
Italy
3 labs
France
1 lab
Japan
1 lab
Nigeria
1 lab
Thailand
1 lab

Sample labs

DEKRA Testing and Certification, S.A.U.
Malaga, ES
Holds: Part 1 · Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1-2 IEC 61215-1-3 IEC 61215-1-4 EN IEC 61215-1-2 EN IEC 61215-1-3 EN IEC 61215-1-4 UNE EN IEC 61215-1-2 UNE EN IEC 61215-1-3 UNE EN IEC 61215-1-4 A Comportamiento en condiciones estándar de medida (CEM) y a temperatura

RETC (Renewable Energy Test Center)
Fremont, CA, US
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1-3 2016 “Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 1-3: Special requirements for testing of thin-film amorphous silicon based photovoltaic (PV) modules” IEC 61215-1-3 2021 “Terrestr

Touchstone Systems & Services
Wyoming, MI, US
Holds: Part not stated on the certificate

IEC 61215, IEC 61646; GM9505P (supurseded 2005 except cycle J) 2, GMW 14124 (except cycle J), GM9132P (superseded 2016)2, GMW 3217, GM2210M (superseded 2017)2; DC-10611; PF9688; FORD 00.00EA-D11-1; FORD WSS-M15P34-D/E; NISSAN NES M

ENERTIS SOLAR, S.L. (Unipersonal) (ENERTIS APPLUS+)
San Sebastián de los Reyes, ES
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-2 + IEC 61215-1-1 A Determinación de potencia máxima (MQT 02) Maximum power determination (MQT 02) IEC 61215-2 + IEC 61215-1-1 A, I Ensayo de Aislamiento (MQT 03) Insulation test (MQT 03) IEC 61215-2 + IEC 61215-1-1 A, I

PAConsult
Hamburg, DE
Holds: Part 2

IEC 61215 -2 2021 -02 Terrestrial photovoltaic (PV) modules - Design qualification and type approval – Part 2: Test procedures MIL -STD 810 2019 -01 +Change 1 2022 -05 Environmental engineering considerations and laboratory tes

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA
Baltimore, MD, US
Holds: Part 2

IEC 61215, Section 10.10; IEC 61646, Section 10.10 Fluid Immersion GR-950; FOTP-12; IEC 60529; ISO 20653; EN 60945 Sec. 8.11; SAE J1455 Sec. 4.4 Waterproofness / Rain RTCA/DO-160 D through G, Sec 10.0; MIL-STD-108 E; MIL-STD-810

SolarPTL, LLC.
Tempe, AZ, US
Holds: Part 2 · Part 4

IEC 61215-4.18; UL 61215-2-4.18; IEC 61730-2-10.8; UL 61730-2-10.8; IEC 61730-2-10.19; UL 61730-2-10.19 Current Injection IEC 61215-4.11 Electrical Insulation ANSI/UL 1703-21; ANSI/UL 1703-26; ULC/ORD C1703-01-5.4; ULC/ORD C170

Auto Technology Company
Strongsville, OH, US
Holds: Part 2

IEC 61215 IEC 61646 IEC 61730-2 IEC 62108

Chemitox, Inc., Yamanashi Testing Center KAI
Yamanashi-ken 408-0103, JP
Holds: Part 2

IEC 61215-2 (Section 4.2, MQT 02); JIS C61215-2 (Section 4.2, MQT 02) Measurement of Temperature Coefficient IEC 61215-2 (Section 4.4, MQT 04); JIS C61215-2 (Section 4.4, MQT 04) Performance at STC IEC 61215-2

ESPEC ENGINEERING (THAILAND) CO.,LTD.
Chonburi, TH
Holds: Part 1-1

IEC 61215-1-1, IEC 60068-2-14 Cold Test Up to -75 °C IEC 60068-2-1 Dry Heat Up to 200 °C IEC 60068-2-2 Temperature and humidity (-75 to 200) °C (20-95) % RH MIL-STD-810; ISO 9455-17; IEC 60068-2-78 Temperature a

PVEL
Napa, CA, US
Holds: Part 2

IEC 61215-2 (MQT 02); IEC 61215-2 (MQT 06); IEC 61215-2 (MQT 07); IEC 61730-2 (MST 02); IEC 61730-2 (MST 03); IEC 62108 (section 10.2.3) Determination of Temperature Coefficients IEC 60891; IEC 61215-2 (MQT 04) Photovoltaic

PV Lab Germany
Potsdam, DE
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215 -2 2016 Terrestrial photovoltaic (PV) modules –Design qualification and type approval –Part 2: Test procedures hier nur: MQT 01 Visual Inspection MQT 03 Insulation test MQT 04 Measurement of temperature coefficients MQT

TUV Rheinland (Shanghai) Co.,
Shanghai, CN
Holds: Part 2 · Part 22

IEC 61215-2 MQT 01; UL 61215-2 MQT 01; CAN/CSA-IEC 61215-2 MQT 01; EN 61215-2 MQT 01; EN IEC 61215-2 MQT 01; IEC 61730-2 MST 01; UL 61730-2 MST 01; EN IEC 61730-2 MST 01; CSA C22.2 No. 61730-2 MST 01; IEC TS 62782 Clause: 5, 7; EN IE

CERTISOLIS TC
LE BOURGET-DU-LAC, FR
Holds: Part 1 · Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-2 NF EN IEC 61215-1-1 NF EN IEC 61215-1-2 NF EN IEC 61215-1-3 NF EN IEC 61215-1-4 Laboratoire fixe CERTISOLIS Performances à STC et à la NMOT MST 03 Modules photovoltaïques pour application terrestre Mesure de la car

Intertek Testing Services NA
Lake Forest, CA, US
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1; IEC 61215-1-1; IEC 61215-1-2; IEC 61215-1-3; IEC 61215-1-4; IEC 61215-2; IEC 61730-1; IEC 61730-2; UL 1703; ULC/ORD-C1703; UL 61730-1; UL 61730-2; UL 61215-1; UL 61215-1-1; UL 61215-1-2; UL 61215-1-3; UL 61215-1-4; UL

Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung eingetragener Verein Fraunhofer Institut für Solare Energiesysteme (ISE) TestLab PV Modules / CallLab PV Modules
Freiburg, DE
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements [Flex A] 1.1.6 IEC 61215-1-1 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - P

WTLAB S.R.L.
Tribano, IT
Holds: Part 1-1 · Part 1-2 · Part 1-4 · Part 2

IEC 61215-1-2:2021 + CEI EN IEC 61215-1:2021 + CEI EN IEC 61215-2:2021, CEI EN IEC 61215-1-2:2021 + CEI EN IEC 61215-2:2021, EN IEC 61215-1-2:2021/A1:2022 + EN IEC 61215-1:2021/AC:2021 + EN IEC 61215-2:2021, EN IEC 61215-1-2:2021/A1:2022 +

QUALIFYING PHOTOVOLTAICS
Madrid, ES
Holds: Part 1-1 · Part 2

IEC 61215-1-1 + IEC 61215-2 (MTQ02) Determinación de la potencia máxima para módulos lineales por comparación con módulo patrón en campo QPV-PE-16 versión R.5 Método interno Caracterización de módulos de referencia en campo, determi

World Standardization Certification & Testing Group (Shenzhen) Co.,
Shenzhen, CN
Holds: Part 1

IEC 61215-1; IEC 62891

TÜV Rheinland (Shanghai) Co.,
CN
Holds: Part 1 · Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1:18* Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements Photovoltaic CAN/CSA-IEC 61215-1- 1:18* Terrestrial photovoltaic (PV) modules - Design qualification and type

Kiwa PI Berlin
Berlin, DE
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215 -1 * 2021-02 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements IEC 61215 -1-1 * 2021-02 Terrestrial photovoltaic (PV) modules - Design qualification and type ap

Standards Organisation of Nigeria, Son Laboratory Services
Lagos, NG
Holds: Part 1-1 · Part 2

IEC 61215-1-1, IEC 61215-2 Maximum Power IEC 61215-1-1, IEC 61215-2 Insulation IEC 61215-1-1, IEC 61215-2 Wet Leakage IEC 61215-1-1, IEC 61215-2

TÜV Rheinland Solar
Köln, DE
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215 -2* 2018-09 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 2: Test procedures EN IEC 61215 -1* 2021-04 + AC:2021-06 Terrestrial photovoltaic (PV) modules - Design qualification an

FUNDACIÓN CIRCE, Centro de Investigación de Recursos y Consumos Energéticos.
Zaragoza, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-2 + IEC 61215-1-1 + IEC 61215-1 I Determinación de potencia máxima (MQT 02) Maximum power determination (MQT 02) IEC 61215-2 + IEC 61215-1-1 I Funcionamiento en condiciones estándar de medida (CEM) (MQT 06.1) Performanc

FUNDACIÓN CENER
Sarriguren, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 1-1 · Part 1-2 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-2 + IEC 61215-1-2 IEC TS 63126 A Estabilización (MQT 19) Stabilization (MQT 19) IEC 61215-2 + IEC 61215-1-2 A, I Ensayo cargas mecánicas cíclicas (MQT 20) Cyclic mechanical loads (MQT 20) IEC 61215-2 IEC 61215-1-2 A

Eurac Research - Istituto per le Energie Rinnovabilii
Bolzano, IT
We don't know yet whether this lab takes outside work.
Holds: Part 1-1 · Part 2

IEC 61215-1-1:2016 + IEC 61215-2:2016/Cor1:2018 - solo/only CEI EN 61215-1-1:2016 § 11.6; CEI EN 61215-2:2017 § 4.6.1, § 4.6.2, § 4.6.3.1; IEC 61215-1-1:2016 § 11.6; IEC 61215-2:2016 § 4.6.1, § 4.6.2, § 4.6.3.1 CEI EN IEC 61215-1-1:2021 +

CS Sunshine Holdings
Mesquite, TX, US
We don't know yet whether this lab takes outside work.
Holds: Part 2

IEC 61215-2 MQT 13 IEC 61730-2 MST 53 UL 61730-2 MST 53 Thermal Cycling Test IEC 61215-2 MQT 11 IEC 61730-2 MST 51 UL 61730-2 MST 51 IEC TS 63126 5.2.5 Humidity-freeze Test IEC 61215-2 MQT 12 IEC 61730-2 MST 52 UL 61730-2 MST 52 P

Illuminate USA
Etna, OH, US
We don't know yet whether this lab takes outside work.
Holds: Part not stated on the certificate

IEC 61215, IEC 61730 Maximum Power Determination IEC 61215, IEC 61730 Insulation Tests IEC 61215, IEC 61730 Performance at STC IEC 61215, IEC 61730 Performance at Low Irradiance IEC 61215 Outdoor Exposure Test IEC 61215 Hot Spot Endur

CFV Solar Test Laboratory, Inc.
Albuquerque, NM, US
We don't know yet whether this lab takes outside work.
Holds: Part 2

IEC 61215-2; IEC 61646 Incidence Angle Effects / Incident Angle Modifier IEC 61853-2 Visual Inspection IEC 61215-2; IEC 61730-2; IEC 61646 Electrical Performance, I-V Characteristics & Max Power (at STC, NOCT/NMOT, Low Irrad

Enel Green Power S.p.A. - Passo Martino Innovation Lab & Hub
Catania, IT
We don't know yet whether this lab takes outside work.
Holds: Part 1-1 · Part 1-3 · Part 1-4 · Part 2

IEC 61215-1-4:2021 + CEI EN IEC 61215-2:2021 _ Moduli Fotovoltaici (FV) per applicazioni terrestri a film sottile in Silicio amorfo/Thin-film amorphous silicon based photovoltaic (PV) modules Denominazione della prova / Campi di prova M