Registers refreshed 2026-11-20.See refresh dates

IEC 61347-1 Accredited Testing Labs Worldwide

Part of a series

See all 56 labs worldwide for IEC 61347 (any part)

Part 1: 51 labs · Part 2-1: 8 labs · Part 2-2: 15 labs · Part 2-3: 15 labs · Part 2-4: 2 labs · Part 2-5: 2 labs and 9 more parts

Go to the series ↑

51 accredited laboratories in 12 countries hold IEC 61347-1 in their accredited scope. We don't know yet whether 13 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body.

Total labs
51
Countries
12

Available in 12 Countries

Germany
17 labs
China
16 labs
Italy
4 labs
Spain
4 labs
Poland
3 labs
Australia
1 lab
United Kingdom
1 lab
Hong Kong SAR China
1 lab
Japan
1 lab
Netherlands
1 lab
Thailand
1 lab
United States
1 lab

Sample labs

DEKRA Testing and Certification, S.A.U.
Malaga, ES

IEC 61347-1 Excepto Apdo./Except Sec. 14.7 Correspondientes a la versión del 2015 o apartados equivalentes en versiones posteriores. Corresponding to 2015 version or equivalent sections in later versions. UNE-EN 61347-2-2 EN 61347-

UL International Germany
Neu-Isenburg, DE

Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung Safety IEC 60335 -2- 75:2012/A1 2015 Amendment 1 - Ho

CTC Laboratories, Inc.
Shenzhen, Guangdong, CN

IEC 61347-1; EN 61347-1; EN IEC 61347-1; AS/NZS 61347.1; IEC 61347-2-13; EN 61347-2-13; EN IEC 61347-2-13; AS 61347.2.13 Plugs and receptacles for domestic and similar general use JIS C 8303; A S/NZS 3112; EN 50075; BS 1363-1 Cla

QIMA Testing (Germany)
Hamburg, DE

IEC 61347-1:2015 Geräte für Lampen – Teil 1: Allgemeine und Sicherheitsanforderungen Deutsche Fassung EN 61347-1:2015 Lamp controlgear – Part 1: General and safety requirements Ausgenommen Abschnitt 8 Prüfungen nach Einschränkung

Suzhou USAI Testing Technology Co.,
Suzhou, CN

IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1; GB 19510.1; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347.2.13; GB 19510.14; IEC 61558-1; EN 61558-1; BS EN 61558-1; AS/NZS 61558.1; GB 19212.1; IEC 61558-2-16

TÜV Rheinland LGA Products
Nürnberg, DE

IEC 61347-1 2012-11 EN 61347-1+A1+A2 2013-01 Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen. (Standort N: mit Ausnahme von Anhang D) Lamp controlgear - Part 1: General and safety requirements. (location N:

TÜV Rheinland Japan Ltd. Yokohama Laboratories Global Technology Assessment Center
JP

Department Standard / in house procedure / Version Title of standard or in house procedure (deviaBons /reducBons modificaBons of standard) LocaBon/ reducBons Product Safety IEC 61010 -2-040:2020 EN 61010-2-040:2021 DIN EN 6

Eurofins Product Service (Thailand) Co.,
Bangkok, TH

IEC 61347-1; EN 61347-1; EN IEC 61347-1 Starting devices (other than glow starters) IEC 61347-2-1; EN 61347-2-1; EN IEC 61347-2-1 A.C. and/or D.C. supplied electronic control gear for fluorescent lamps IEC 61347-2-3; EN 61347-2-3; EN I

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE

IEC 61347-1:2015 + A1:2021 EN 61347-1:2015 DIN EN 61347-1: :2021-08 VDE 0712-30:2016 VDE 0712-30:2021-08 Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen A IEC 61347-2-1:2000 + AMD1:2005 + AMD2:2013 EN 6134

CSA Group Bayern
Plattling, DE

Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkung zum Prüfverfahren Sicherheit EN 60598-2-22:2022 Luminaires - Part 2-22: Particular requirements - Luminaires for emergenc

Intertek Testing Services NA
Cortland, NY, US

IEC 61347-1, -2-13, IEC 62031; EN 60598-1:2015, -2-1:1998, -2-2:2012, -2-3:2003, -2- 4:1997, -2-5:1998, -2-18:1994, -2-22:1998, -2-23:1996, EN 61347-1:2008, -2-13:2006, EN 62031:2008; AS/NZS 60598.1, 2.1, 2.2, 2.3, 2.4, 2.5, 2.18, 2.22,

Eurofins Electrical Testing Service (Shenzhen) Co.,
Shenzhen City, Guangdong, CN

Annex CC Evaluation of integrated circuit (IC) current limiters; Annex Zx Protection against excessive sound pressure from personal music players IEC/EN 60065 6.1 Ionizing Radiation 6.2 Laser radiation 8.17 Endurance test for wou

DEKRA Testing and Certification
Stuttgart, DE

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Anforderungen - Kleinspannungsbeleuchtungssysteme für Glühlampen LITE IEC 60598 -2-24:2013 EN 60598

NEMKO
Pfinztal, DE

IEC 61347-1:2015 + A1:2017); Deutsche Fassung EN 61347-1:2015 + A1:2021 Elektro- technik DIN EN 61347-2-11:2019-11 Geräte für Lampen - Teil 2-11: Besondere Anforderungen an elektronische Module für Leuchten (IEC 61347-2-11:2001 + C

EMC Technologies Pty.
Melbourne, AU

Test Description: Test Method(s)1,2: Product Safety Lamp control gear AS/NZS 61347.1, IEC/EN 61347-1; AS/NZS 61347.2.2, IEC/EN 61347-2-2; AS/NZS 61347.2.3, IEC/EN 61347-2-3; AS/NZS 61347.2.8, IEC/EN 61347-2-8; AS/NZS 61347.2.11, IE

Eurofins Electrical Testing Service (Shanghai) Co.,
Shanghai, CN

IEC 61347-1; EN 61347-1; EN IEC 61347-1; AS/NZS 61347.1; ABNT NBR IEC 61347-1; J61347-1

Stowarzyszenie Elektryków Polskich, ul. Świętokrzyska 14, 00-050 Warszawa, Biuro Badawcze ds. Jakości
Warszawa, PL

IEC 61347-1:2015+Amd1:2017 PN-EN 61347-1:2015-09 EN 61347-1:2015 Układy elektroniczne stosowane w oprawach oświetleniowych Trwałość znakowania Napięcie, pobór prądu i mocy elektrycznej, kształt krzywej prądu Wymiary i konstrukcja z

TÜV SÜD Hong Kong
Hong Kong, HK

IEC 61347-1:2008 + A1:2010 + A2:2012 IEC 61347-1:2015 + A1:2017 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-1:2015 EN 61347-1:2015 + A1:2021 DIN EN 61347-1:2016 VDE 0712-30:2016 AS/NZS 61347.1:2002 AS/NZS 61347.1:2016 +

Element Materials Technology Straubing GmbH Element Materials Technology Straubing
Straubing, DE

IEC 61347-1:2015 + A1:2017); Deutsche Fassung EN 61347-1:2015 + A1:2021 Elektro- technik IEC 61347-1:2015-02-19 + A1:2017-09 Lamp controlgear - Part 1: General and safety requirements Elektro- technik I.S. EN 61347-2-11:2001

TÜV SÜD Product Service
Garching, DE

IEC 61347-1:2015 Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen DIN EN 61347 -2-7 (VDE 0712-37):2023-03 EN 61347-2-7:2012 + A1:2019 + A2:2022 IEC 61347-2-7:2011 + A1:2017 + A2:2021 Geräte für Lampen - Teil 2

Shenzhen Tongzhou Testing Co.,
Shenzhen, CN

IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347-1; IEC 61347-2-11; EN 61347-2-11; BS EN 61347-2-11; AS/NZS 61347-2-11; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347-2-13

Eurofins Product Service
Reichenwalde, DE

IEC 61347-1:2015 + A1:2017); Deutsche Fassung EN 61347-1:2015 + A1:2021 Elektr. Sicherheit / Safety EN 61347- 1:2015+A1:2021 Lamp controlgear - Part 1: General and safety requirements (IEC 61347- 1:2015/A1:2017) Elektr. Sic

EUROFINS ELECTRICAL AND ELECTRONIC UK LIMITED (Trading as Eurofins E&E UK – London Laboratory)
London, GB

IEC 61347-1:2015 +A1:2017 Excluding: Clause 14.7 Annex P EN 61347-1:2008, + A1 + A2 IEC 61347-1:2007, + A1 + A2 EN 61347-1:2001 (withdrawn) IEC 61347-1:2000 DC and AC supplied electronic step down converters for filament la

Intertek Deutschland
Kaufbeuren, DE

IEC 61347-1:2015 + A1:2017 EN 61347-1:2015 + A1:2021 IEC 61347-1:2015 EN 61347-1:2015 Lamp controlgear – Part 1: General and safety requirements. Geräte für Lampen – Teil 1: Allgemeine und Sicherheitsanforderungen. LITE IEC 61

Bestway Compliance Co.,
Dongguan, CN

IEC 61347-1:2015; IEC 61347-1:2015+A1:2017; EN 61347-1:2015+A1:2021; AS/NZS 61347.1:2016+A1:2018; AS/NZS 61347.1:2016 Rul 1:2020; GB19510.1-2009 Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electr

DEKRA Certification
ARNHEM, NL

IEC 61347-1, EN 61347-1 IEC 61347-2-1, EN 61347-2-1 IEC 61347-2-2, EN 61347-2-2 IEC 61347-2-3, EN 61347-2-3 IEC 61347-2-7, EN 61347-2-7 IEC 61347-2-8, EN 61347-2-8 IEC 61347-2-9, EN 61347-2-9 IEC 61347-2-11, EN 61347-2-11 IEC 61347

Elettra
Calenzano, IT

Elettra Srl via Felice Matteucci, 10 50041 Calenzano FI Allegato al certificato di accreditamento n. 00968 rev. 6 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 10 Sede A Data: 23/01/2025 pag. 32 di 32 Spine e prese pe

TUV Rheinland (Shanghai) Co.,
Shanghai, CN

IEC 61347-1; IEC 61347-1:2000; IEC 61347-1:2000+A1:2003; IEC 61347-1:2007; IEC 61347-1:2007+A1:2010; IEC 61347-1:2015; IEC 61347-1:2015+A1:2017; IEC 61347-1:2024; EN 61347-1; BS EN 61347‑1; AS/NZS 61347.1; J61347-1; JIS C 8147-1 La

Shenzhen United Testing Technology Co.,
Shenzhen, Guangdong, CN

Test Technology: Test Method(s) 1: Product Safety 2 (cont.) GB/T 7000.208 (excluding clause 6.6.2); AS/NZS 60598.2.12; IEC/EN/BS

Attestation of Global Compliance (Shenzhen) Co.,
Guangdong, CN

IEC 61347-1; EN 61347-1; AS/NZS 61347.1; BS EN 61347-1; IEC 61347-2-11; EN 61347-2-11; AS/NZS 61347.2.11; BS EN 61347-2-11; IEC 61347-2-13; EN 61347-2-13; AS/NZS 61347.2.13; BS EN 61347-2-13; IEC 61558-1/EN IEC 61558-1/AS/NZS 61558.1

WTLAB S.R.L.
Tribano, IT

WTLAB S.R.L. Via Andrea Mantegna 3-5 35020 Tribano PD Allegato al certificato di accreditamento n. 01077 rev. 4 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 26 Sede A Data: 22/12/2025 pag. 14 di 17 Unità di alimentaz

Shenzhen HUAK Testing Technology Co.,
Shenzhen, CN

IEC 61347-1, EN 61347-1, AS/NZS 61347.1 (excluding Clause 14.7); IEC 61347-2-13, EN 61347-2-13, AS/NZS 61347.2.13 (excluding Clause 14.7); IEC 60335-1, EN 60335-1, AS/NZS 60335.1 (excluding Clauses 15.1, 21.2, 22.32, 22.46

Shenzhen UnionTrust Quality and Technology Co.,
Shenzhen, Guangdong, CN

IEC 61347-1; EN 61347-1; AS/NZS 61347.1; IEC 61347-2-13; EN 61347-2-13; AS/NZS IEC 61347.2.13; BS EN 61347-1; BS EN 61347-2-13 Automatic Electrical Controls for Household and Similar use IEC 60730-1; EN 60730-1; IEC 60730-2-7; EN

Dongguan New Testing Centre Co.,
Dongguan, CN

IEC 61347-1:2015+A1:2017; EN 61347-1:2015+A1:2021; AS/NZS 61347.1:2016; AS/NZS 61347.1:2016+A1:2018; NMX-J-058-ANCE-2017; J61347-1(H29); BS EN 61347-1:2015+A1:2021 Lamp controlgear - Part 2-7: Particular requirements for batte

SLG Prüf- und Zertifizierungs
Hartmannsdorf, DE

Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions IEC 61347 -1:2015 EN 61347-1:2015 DIN EN 61347- 1:2016 Lamp con

Kiwa Primara
Kaufbeuren, DE

IEC 61347-1: 2007+ A1:2010 + A2: 2012 IEC 61347-1:2010-11 EN 61347-1:2008 + A1:2011 + A2:2013 EN 61347-1:2008/ FprA3:2013 EN 61347-1:2008/ FprA2:2011 Fpr DIN EN 61347-1/ A3:2013 DIN EN 61347-1:2013 DIN EN 61347-1:2011 DIN EN

TUV Rheinland Italia
Pogliano Milanese, IT

IEC 61347-1:2024 EN 61347-1:2015/A1:2021, IEC 61347-1:2015/AMD1:2017 Tecnica di prova O&I _ _ Metodo di prova GB/T 18387:2017 Tecnica di prova O&I _ Veicoli motorizzati leggeri per il trasporto di persone e merci e relative strut

TUV SUD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Shenzhen, CN

IEC 61347-1; EN 61347-1; GB/T 19510.1; AS/NZS 61347.1 Lamp controlgear – Part 2: Particular requirements - Section 7: Battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-7; EN 61347-2-7; G

Shenzhen VOP Testing Technology Co.,
Shenzhen, Guangdong, CN
We don't know yet whether this lab takes outside work.

IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1; IEC 61347-2-12; EN 61347-2-12; BS EN 61347-2-12; AS/NZS 61347.2.12; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347.2.13 Electric Motor-Operated Hand- He

Guangdong Asia Hongke Test Technology
Shenzhen, Guangdong, CN
We don't know yet whether this lab takes outside work.

IEC 61347-1; EN 61347-1; EN IEC 61347-1; AS/NZS 61347.1; NMX-J-058-ANCE-2017; J61347-1(2022); BS EN 61347-1; BS EN IEC 61347-1 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear fo

LABORATORIO DE ENSAYOS DEL AYUNTAMIENTO DE ZARAGOZA
Zaragoza, ES
We don't know yet whether this lab takes outside work.

Anexo Técnico Nº 21/LE270 Rev. 24 Pág. 1 de 2 LABORATORIO DE ENSAYOS DEL AYUNTAMIENTO DE ZARAGOZA Dirección: Ctra. de Cogullada, s/n; 50014 Zaragoza Norma de referencia: UNE-EN ISO/IEC 17025:2017 Actividad: Ensayo Acreditación n

Sieć Badawcza Łukasiewicz - Instytut Mikroelektroniki i Fotoniki
Warszawa, PL
We don't know yet whether this lab takes outside work.

IEC 61347-1:2015 IEC 61347-1:2024 PN-EN 61347-2-1:2005+A1+A2+AC EN 61347-2-1:2001+CORR.:2003+ A1+A2+AC IEC 61347-2-1:2000+AMD2 IEC 61347-2-1:2024 PN-EN 61347-2-2:2012 EN 61347-2-2:2012 IEC 61347-2-2:2011 IEC 61347-2-2:2024 PN-E

Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Warszawa, PL
We don't know yet whether this lab takes outside work.

Przedmiot badań/wyrób Rodzaj działalności/badane cechy/ metoda Dokumenty odniesienia Urządzenia do lamp Trwałość znakowania Wymiary i konstrukcja zacisków Ciągłość połączeń ochronnych Rezystancja połączeń ochronnych Ochrona przed p

Deutsche Gesetzliche Unfallversicherung e.V. (DGUV) DGUV Test, Prüf- und Zertifizierungsstelle Elektrotechnik Fachbereich Energie, Textil, Elektro und Medienerzeugnisse
Köln, DE
We don't know yet whether this lab takes outside work.

IEC 61347-1:2015-02 EN 61347-1:2015-05 DIN EN 61347-1 (VDE 0712-30):2016-05 Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen Lamp controlgear - Part 1: General and safety requirements Nur Prüflabor Dresden

Regierungspräsidium Kassel Hessische Geräteuntersuchungsstelle
Kassel, DE
We don't know yet whether this lab takes outside work.

Norm / Ausgabedatum Hausverfahren /Version Titel der Norm oder des Hausverfahrens Einschränkungen DIN EN 60598-2-22 / VDE 0711-2-22:2015-06 + Ber.1:2016-09 + Ber.2:2017-05 EN 60598-2-22:2014 Leuchten - Teil 2-22: Beson

IMQ IBÉRICA, S.L. (Unipersonal)
Picanya, ES
We don't know yet whether this lab takes outside work.

IEC 61347-1 EN IEC 61347-1 IEC 61347-1:2015 IEC 61347-1:2015/A1:2017 EN 61347-1:2015 EN 61347-1:2015/A1:2021 Dispositivos de control electrónicos alimentados en c.a y/o c.c. para lámparas fluorescentes, excepto dispositivos para a

LABORATORIO CENTRAL OFICIAL DE ELECTROTECNIA (LCOE) DE LA FUNDACIÓN PARA EL FOMENTO DE LA INNOVACIÓN INDUSTRIAL
Getafe, ES
We don't know yet whether this lab takes outside work.

IEC 61347-1 A Prescripciones de funcionamiento Performance requirements EN 60921 IEC 60921 A Código Validación Electrónica: 1jS0j9fs23Gd2PTjxk La acreditación mantiene su vigencia hasta notificación en contra. La presente acreditació

OSRAM
Garching, DE
We don't know yet whether this lab takes outside work.

IEC 61347-1:2015); Deutsche Fassung EN 61347-1:2015 Ausgenommen: Beständigkeit gegen Korrosion (Resistance to corrosion) Dornradprüfung (mandrel test) IEC 61347-1:2015 Lamp controlgear – Part 1: General and safety requirements

Shenzhen Haiyun Standard Technical CO.,
Shenzhen, CN
We don't know yet whether this lab takes outside work.

IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1; GB 19510.1; IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13; AS/NZS 61347.2.13; GB 19510.14; GB 19212.1 Energy ERP COMMISSION REGULATION (EU) 2019/2021; COMMISSION DELEG

Staatliches Gewerbeaufsichtsamt Hildesheim Gerätesicherheitsprüfstelle Dezernat 34
Hildesheim, DE
We don't know yet whether this lab takes outside work.

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Niederspan- nungsgeräte DIN EN 60598-2-12 (VDE 0711-2-12) 2014-03 Leuchten - Teil 2-12: Besondere Anfo

Showing labs 1–50 of 51. Use pagination below to see more.

Other parts

All parts on the series page →