ISO 15883 Accredited Testing Labs Worldwide
ISO 15883, all parts: Washer-disinfectors. Each lab card shows which parts it holds.
- ISO 15883-1Part 1: General requirements, terms and definitions and tests21 labs →
- ISO 15883-2Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for critical and semi-critical medical devices12 labs →
- ISO 15883-3Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers5 labs →
- ISO 15883-4Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes16 labs →
- ISO 15883-5Part 5: Performance requirements and test method criteria for demonstrating cleaning efficacy11 labs →
- ISO 15883-6Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection for non-critical medical devices and health care equipment5 labs →
- ISO 15883-7Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-critical thermolabile medical devices and health care equipment7 labs →
30 accredited laboratories in 5 countries hold ISO 15883 in their ISO/IEC 17025 scope. Primary accreditors include Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service, Irish National Accreditation Board. In the register, ISO 15883 scope entries most often cover Sterilität, Pseudomonas Aeruginosa, Biofilm Levels in Water, Drinking water, Medical devices.
Available in 5 Countries
Top matrices for ISO 15883
Top analytes for ISO 15883
- Sterilität (3)
- Pseudomonas Aeruginosa (2)
- Biofilm Levels (1)
- Environmental Mycobacteria (1)
- Free Nh2 Groups Of Blood Proteins (1)
- Geobacillus Stearothermophilus (1)
- Geobacillus Stearothermophilus Spores (1)
- Enterococci (1)
Sample labs
ISO 15883-6 (2016-04); DIN EN ISO 15883-7 (2016-10); Brill, Krüger, Zschaler: Kapitel I, 2.5 (2017-08); Brill, Krüger, Zschaler: Kapitel 3.5.3 (2017-08) (W: nur Dekontaminationslösungen) Bioindikatoren, Desinfektions- mittellösungen B, L, W
ISO 15883- 1:2006/Amd 1:2014 Washer Disinfectors Part 1 and ISO 15883- 4:2018 Washer Disinfectors - Part 4 Incubation and Enumeration of SDA Plates at 22.5ᵒC Plate count Factory Hygiene Surfaces Factory Hygiene Air N/A CLS
ISO 15883-4: 2019-06 Reinigungs-Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN EN ISO 15883-5: 2021-11 Reinigungs-Desinfektionsg
ISO 15883- 4:2024, Annex E3, HTM 01-06 Part E, WHTM 01-06 Part ,NI/HTM 0106 part E and SHTM 0106 part E D Washer Disinfector, Final Rinse Waters (fed by reverse osmosis supply), Reverse Osmosis water, AER Final Rinse Water En
Edition 9, 16/01/2026 Scope of Accreditation Head Office Biological and Veterinary Testing Category: A Biology/veterinary field - Tests Test name Technique Matrix Equipment St
ISO 15883-1 Reinigungs-Desinfektionsgeräte — Teil 1: Allgemeine Anforderungen, 2014-10 Begriffe und Prüfverfahren DIN EN ISO 15883-2 2009-09 DIN EN ISO 15883-4 2019-06 Reinigungs-Desinfektionsgeräte —Teil 2: Anforderungen und Prüfverfahren
ISO 15883-3:2006) DIN EN ISO 15883-4 : 2019-09 Reinigungs-Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope (ISO 15883-4:2018) DIN I
ISO 15883-2 : 2009-09 Washer-disinfectors - Part 2: Requirements and tests for washer- disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. (ISO 1
ISO 15883- 4:2018, Annex E3 and HTM 01-06 Part E 2016 L Heater Cooler Unit Waters Environmental Mycobacteria at 35 °C for 6-8 weeks L015 using membrane filtration onto supplemented Middlebrook 7H11 Agar and Ziehl Neelsen S
ISO 15883-1: 2014-10 Washer-disinfectors - Part 1: General requirements, terms and definitions and tests (ISO 15883-1:2006 + Amd. 1:2014) DIN EN ISO 15883-4: 2019-06 Washer-disinfectors - P art 4: Requirements and tests for washer- dis
ISO 15883- 4:2018 and Annex B, plus HTM 01- 06 Part E 2016
ISO 15883-1 : 2014-10 Reinigungs-Desinfektio nsgeräte - Teil 1: Allgemeine Anforderungen, Begriffe und Prüfverfahren (ISO 15883-1:2006 + Amd 1:2014) DIN EN ISO 15883-2 : 2009-09 Reinigungs-Desinfektio nsgeräte - Teil 2: Anforderungen un
ISO 15883- 5:2009 Annex F Evaluation of Bacterial Contamination levels as a measure of Disinfection Efficacy SOP 107 assessment of contamination levels of Pseudomonas aeruginosa, Escherischia coli and Staphylococcus aureus leve
ISO 15883-1: 2024. Lab Ref L006 803 Culture of organisms in liquid or agar based culture media with visual or instrument monitoring for growth - .02 Culture of fungi Culture of organisms in liquid or agar based culture media with vi
ISO 15883-1 : 2014-10 Reinigungs-Desinfektionsgeräte - Teil 1: Allgemeine Anforderungen, Begriffe und Prüfverfahren (ISO 15883-1 : 2006 + Amd 1 : 2014) DIN EN ISO 15883-2 : 2009-09 Reinigungs-Desinfektionsgeräte - Teil 2: Anforderungen u
Assessment Manager: PC3 Page 1 of 1 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 10547 Accredited to ISO/IEC 17025:2017 Medipure Lt