AKUVIB Engineering and Testing
Bochum, DE
IEC 61000-4-4-2012); Deutsche Fassung EN 61000-4-4:2012 Prüflinge bis 400 V / 63 A
99 laboratories in Germany are accredited by DAKKS to perform IEC 61000-4-4 testing. We don't know yet whether 47 of them take outside work. From the accredited scope text: “IEC 61000-4-4 2012-04 Ed. 3.0 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test EN 61000-4-5 2014-08 +A1:2017-11 Electr” “IEC 61000-4-4:2004) EMV DIN EN 61000 -4-5 VDE 0847-4-5: 2007 Elektromagnetische Verträglichkeit (EMV) - Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen (IEC 61000-4” “IEC 61000-4-4:2012) EMV DIN EN 61000 -4-5:2009 -03 +Correction 1:2021-04 (EN 61000-4-5:2014 + A1:2017) Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immuni” “IEC 61000-4-4:2012) EMV DIN EN 61000 -4-5 VDE 0847-4-5:2019 (EN 61000-4-5:2014+ A1:2017) Ele ktromagnetische Verträglichkeit (EMV) – Teil 4-5: Prüf- und Messverfahren – Prüfung der Störfestigkeit gege”
Bochum, DE
IEC 61000-4-4-2012); Deutsche Fassung EN 61000-4-4:2012 Prüflinge bis 400 V / 63 A
Essen, DE
IEC 61000-4-4:2012) Deutsche Fassung EN 61000-4-4:2012 EMV DIN EN 61000-4-5:2019-03 VDE 0847-4-5:2019-03 Elektromagnetische Verträglichkeit (EMV) - Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen
Regensburg, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen 1 Grundnormen EMV DIN EN 61000 -4-2 (VDE 0847-4-2) 2009 Elektromagnetische Verträglichkeit (EMV) - Teil 4-
Maulburg, DE
IEC 61000-4-4:2012); German Version EN 61000-4-4:2012 Only single-phase CDN for supply line EMC IEC 61000-4-4:2012 Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques - Electrical fast transient/burst
Erlangen, DE
IEC 61000-4-4:2004 Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques - Electrical fast transient / burst immunity test
Heidesee OT Kolberg, DE
IEC 61000-4-4:2012) EMV DIN EN 61000-4-5: 2019-03 EMV Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen (IEC 61000-4-5:2014 + A1:2017) Prüfung nur auf Netzleitungen EMV DIN EN 61000-4-6: 2014-0
Karlsruhe, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4- 4:2012 EMV IEC 61000 -4-4:2012 -04 (Edition 3.0) Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity t
Lippstadt, DE
Bereich Norm/ Prüfverfahren/Version Titel des Standards oder Prüfverfahrens Prüfbereich/ Einschränkung EMV ISO 7637 -2:2011 -03 Road vehicles − Electrical disturbances from conduction and coupling – Part 2: Electrical transient condu
Bad Neustadt a.d. Saale, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4-4:2012 EMV DIN EN 61000-4-5 VDE 0847-4-5 (2015-03) Elektromagnetische Verträglichkeit (EMV) Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen
Kirchheim, DE
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens 1 Prüfbereich / Einschränkungen 1 Grundnormen EMV DIN EN 61000 -4-2:2009 -12; VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil
Petersberg, DE
IEC 61000-4-4:2012) DIN EN 61000 -4-5 2019-03 Elektromagnetische Verträglichkeit (EMV) - Teil 4 -5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen (IEC 61000-4-5:2014 + A1:2017) DIN EN 61000 -4-8 2010-
Regensburg, DE
IEC 61000-4-4 Ed 3.0 2012-04 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test EMV IEC 61000-4-5 Ed 3.1 2017-08 Electromagnetic compatibility (EMC) –
Oberkochen, DE
EMV am Standort Aalen Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung 1. Elektromagnetische Verträglichkeit 1.1. Grundnormen EMV DIN EN 61000 -4-2: 2009 EN 61000-4-2
Lüdenscheid, DE
IEC 61000-4-4:2012) EMV IEC 61000 -4-4:2012 -04 Edition 3.0 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test EMV DIN EN 61000 -4-5: 2015-03 (
Überlingen, DE
IEC 61000-4-4 (2012) Elektromagnetische Verträglichkeit (EMV) – Teil 4-4: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgrößen/Burst Electromagnetic compatibility (EMC) – Part 4-4 : Tes
Brühl, DE
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Testing field Standard / in house procedure / Version Title of standard or in house procedure Test range / r
Amberg, DE
IEC 61000-4-4:2012) EMV IEC 61000 -4-5:2014 + AM1:2017 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test only one line measurement no 10/700 μs combination EMV DI
Böblingen, DE
IEC 61000-4-4:2004); Deutsche Fassung EN 61000-4-4:2004 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4:2004); German version EN 61000-4
Ostfildern, DE
Bereich Norm/ Hausverfahren/ Version Titel der Norm Prüfbereich / Einschränkungen EMV IEC 61000 -4-4:2012 -04 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/ burst im
Karlsruhe, DE
Fach - bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren CISPR 14 -2:2015 Electromagnetic compatibility - Requirements for household appliances, electric tool
Bergisch Gladbach, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4-4:2012 Tischgeräte, einphasig DIN EN 61000-4-5:2015 (EN 61000-4-5:2014) Elektromagnetische Verträglichkeit (EMV) - Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigke
Bielefeld, DE
This document is a translation. The definitive version is the original German annex to the accreditation certificate. The listed testing methods are exemplary. The testing laboratory maintains a current list of all testing methods withi
Regensburg, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV IEC 61000 -3-12 Ed 2.1 2021-06 Electromagnetic compatibility (EMC) – Part 3-12: Limits - Limits for
Oppenweiler, DE
IEC 61000-4-4: 2012-04 ed.3.0 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test EMV DIN EN 61000-4-5 Ber 1 VDE 0847-4-5:2021-04 Elektromagnetische V
Nürnberg, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4-4:2012 keine Prüfung am Aufstellungsort; nur ≤ 16 A einphasig EMV EVS-EN 61000-4-4:2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical
Garching, DE
IEC 61000-4-4:2004); Deutsche Fassung EN 61000-4-4:2004 IEC 61000-4-4:2004 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test DIN EN 61000-4-4:2013
Neuhausen auf den Fildern, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4-4:2012 EMV DIN EN 61000-4-5; VDE 0847-4-5:2019 Elektromagnetische Verträglichkeit (EMV) - Teil 4-5: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Stoßspannungen (IEC 6100
Brühl, DE
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Depart ment Standard / in house procedure / Version Title of standard or in house procedure Test area / reduct
Waldkirch, DE
Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN 61000 -4-4:2013 Elektromagnetische Verträglichkeit (EMV) – Teil 4-4: Prüf- und Messverfahren
Schwieberdingen, DE
IEC 61000-4-4: 2012 (EN 61000-4-4) Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test EMV IEC 61000-4-5: 2014 + A1:2017 (EN 61000-4-5) Electromagneti
Regensburg, DE
IEC 61000-4-4 (2012) Electromagnetic compatibility (EMC) – Part 4-4 : Testing and measurement techniques – Electrical fast transient/burst immunity test EMV DIN EN 61000-4-5 (2019) Elektromagnetische Verträglichkeit (EMV) – T
Würzburg, DE
IEC 61000-4-4 2012-04 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test (Adopted IEC 61000-4-4:2012, third edition, 2012-04) Nur 6.2+6.3 für DC Aut
Fulda, DE
IEC 61000-4-4:2012) EMV DIN EN 61000 -4-5 VDE 0847-4-5:2019 (EN 61000-4-5:2014+ A1:2017) Ele ktromagnetische Verträglichkeit (EMV) – Teil 4-5: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen Stoßspannungen (IEC 61000-
Wuppertal, DE
IEC 61000-4-4:2012- 04 Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test DIN EN 61000-4- 4:2013-04 Teil 4-4: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle transient
München, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren / Einschränkungen 1 Grundnormen EMV DIN EN 61000 -4-2; VDE 0847-4-2:2009 (EN 61000-4-2) Elektromagnetische Verträglichkeit
Balingen, DE
IEC 61000-4-4:2012) EMV DIN EN 61000 -4-5:2009 -03 +Correction 1:2021-04 (EN 61000-4-5:2014 + A1:2017) Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test (IEC 61000-4-5:201
Ratingen, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren 1 Elektromagnetische Verträglichkeit (EMV) 1.1 Grundnormen EMV EN 61000-4-2:2009 DIN EN 61000-4-2; VDE 0
Werdohl, DE
Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der mit [Flex A] gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormt
Kassel, DE
IEC 61000-4-4:2012); Deutsche Fassung EN 61000-4-4:2012 max. 63A/Phase EMV DIN EN 61000-4-4; VDE 0847-4-4:2005 Elektromagnetische Verträglichkeit (EMV) - Teil 4-4: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle t
Erlangen, DE
Bereich Norm / Hausverfahren/ Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Norm- verfahren angeben) Prüfbereich/ Einschränkung EMV IEC 61000 -4-4:2012 Electromagnetic compatibility (EMC)
Langen, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren inductive coupling via lines other than supply lines EMV ISO 10605:2023 -06 Edition 3.0 Road vehicles – T
Dortmund, DE
DIN EN 1158 2003-04 Berichtigung 1 2006-06 Schlösser und Baubeschläge - Schließfolgeregler - Anforderungen und Prüfverfahren DIN EN 1191 2013-04 Fenster und Türen – Dauerfunktionsprüfung - Prüfverfahren DIN EN 1628 2
Zwickau, DE
IEC 61000-4-4 ed 2.0 - 2004 Elektromagnetische Verträglichkeit (EMV) - Teil 4-4: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgrößen/Burst Ladeleistung ≤ 50 kW, max. 32 A AA
Niestetal, DE
Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist, ohne dass es einer vorher igen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormt en oder ihnen gleichzusetzenden Prüfverfahren mit unter
Lübeck, DE
IEC 61000-4-4 2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient / burst immunity test Single phase only DIN EN 61000-4-4: 2013-04 Electromagnetic compatibility (EM
Detmold, DE
IEC 61000-4-4:2012); German version EN 61000-4-4:2012 PB) EMC IEC 61000 -4-5 :2014 Electromagnetic compatibility (EMC) - Part 4 - 5: Testing and measurement techniques - Surge immunity test PB) EM C DIN EN 61000 -4-5 :2015 Elect
Heimsheim, DE
IEC 61000-4-4 2012-04 Teil 4-4: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgrößen/Burst Without: CCC EMV IEC 61000-4-5 2017-08 Part 4-5: Testing and measurement techniques - Surg
Jena, DE
Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Einschränkung zum Prüfverfahren 2 Fachbereich Elektromagnetische Verträglich
Braunschweig, DE
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren 1 Elektromagnetische Verträglichkeit 1.1 Grundnormen EMV DIN EN 61000-4-2; VDE 0847-4-2:2009 (EN 61000-4-2)
Showing labs 51–99 of 99. Use pagination below to see more.
Deutsche Akkreditierungsstelle (DAKKS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Germany.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.