Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

EN 55025 Accredited Testing Labs in United States

7 laboratories in United States are accredited by A2LA to perform EN 55025 testing. We don't know yet whether 1 of them takes outside work. From the accredited scope text: “EN 55025 (sections 6.3 and 6.4); ECE Regulation 10 ESD ISO 10605; ISO 10605:2008 Bulk Current Injection (BCI) ISO 11451-1; ISO 11452-4 Immunity of vehicles to electromagnetic disturbances from on-boar” “EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017 RF Immunity – Absorber Lined Shielded Enclosure (ALSE) ISO 11452-2 RF Immunity – Bulk Current Injection (BCI) ISO 11452-4; SAE J1113-4; ISO 11451-2” “EN 55025; EN 55022; CISPR 22; AS/NZS/CISPR 11; AS/NZS/CISPR 22; AS/NZS/CISPR 32; RRL 2006-84; RRL 2005-128; RRL 2005-96; CISPR 11; EN 55011; KS C 9811; EN 55014-1 (excluding measurements of clicks); K” “EN 55025 (clauses 6.3, 6.4, 6.5 only) Current Harmonics EN/IEC 61000-3-2 Voltage Fluctuations & Flicker EN/IEC 61000-3-3”

Labs
7
Primary AB
A2LA7 labs

Accredited Labs

Nebraska Center for Excellence in Electronics

Lincoln, NE, US

Scope

EN 55025; CISPR 25 (Section 6.2, 6.3, and 6.5 only) Immunity, Multimedia Equipment EN 55035; CISPR 35; KS C 9835; SANS 2335 Emissions, Multimedia Equipment EN 55032; CISPR 32; KS C 9835; AS/NZS CISPR 32 Electrical and Electroni

View lab

Element Materials Technology - Melbourne

Melbourne, FL, US

Scope

EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017 RF Immunity – Absorber Lined Shielded Enclosure (ALSE) ISO 11452-2 RF Immunity – Bulk Current Injection (BCI) ISO 11452-4; SAE J1113-4; ISO 11451-2

View lab

Element Materials Technology Chicago - Mt. Prospect

Mount Prospect, IL, US

Scope

EN 55025 (sections 6.3 and 6.4) Conducted Transient Immunity along supply lines ISO 7637-2 Conducted Transient Immunity via lines other than supply lines ISO 7637-3 ESD ISO 10605; ISO 10605:2008 Immunity of vehicles to elec

View lab

Element Materials Technology Rockford

Rockford, IL, US

Scope

EN 55025 (sections 6.3 and 6.4); ECE Regulation 10 ESD ISO 10605; ISO 10605:2008 Bulk Current Injection (BCI) ISO 11451-1; ISO 11452-4 Immunity of vehicles to electromagnetic disturbances from on-board transmitters ISO 11451-

View lab

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA

Santa Clara, CA, US

Scope

EN 55025; EN 55022; CISPR 22; AS/NZS/CISPR 11; AS/NZS/CISPR 22; AS/NZS/CISPR 32; RRL 2006-84; RRL 2005-128; RRL 2005-96; CISPR 11; EN 55011; KS C 9811; EN 55014-1 (excluding measurements of clicks); KS C 9814-1:2022; VCCI V-3 (up t

View lab

Element Materials Technology Boxborough

Boxborough, MA, US

Scope

EN 55025 (clauses 6.3, 6.4, 6.5 only) Current Harmonics EN/IEC 61000-3-2 Voltage Fluctuations & Flicker EN/IEC 61000-3-3

View lab

Garmin Compliance

Olathe, KS, US

We don't know yet whether this lab takes outside work.
Scope

EN 55025: 2017; EN 55025: 2022; EN 55025; EN 55032: 2012 +AC: 2013; EN 55032: 2015 +A11: 2020; EN 55032: 2015 +A1: 2020; EN 55032; EN 61000-3-2: 2014; EN 61000-3-2: 2018; EN 61000-3-2: 2018 +A1:2020; EN 61000-3-2: 2018 +A1: 2

View lab

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches