EN 55016 Accredited Testing Labs Worldwide
EN 55016, all parts. Each lab card shows which parts it holds.
- EN 55016-1-1Part 1-11 lab →
- EN 55016-1-2Part 1-25 labs →
- EN 55016-1-3Part 1-32 labs →
- EN 55016-1-4Part 1-45 labs →
- EN 55016-2Part 21 lab →
- EN 55016-2-1Part 2-152 labs →
- EN 55016-2-2Part 2-222 labs →
- EN 55016-2-3Part 2-346 labs →
- EN 55016-2-4Part 2-410 labs →
- EN 55016-4-2Part 4-21 lab →
58 accredited laboratories in 9 countries hold EN 55016 in their ISO/IEC 17025 scope. Primary accreditors include Deutsche Akkreditierungsstelle, Italian Accreditation Body, United Kingdom Accreditation Service. In the register, EN 55016 scope entries most often cover Conducted Emissions, Harmonics, Hochfrequente Störaussendung in Electrical equipment.
Available in 9 Countries
Top matrices for EN 55016
Top analytes for EN 55016
- Conducted Emissions (1)
- Harmonics (1)
- Hochfrequente Störaussendung (1)
- Interference Emission (1)
- Oberschwingungsströme (1)
- Radiated Emissions (1)
- Rf Voltages (1)
- Unintentional Radiators Emissions (1)
Sample labs
EN 55016-2-1:2014/A1:2017/AC:2020 _ _ _ _ Misura dei disturbi irradiati/Radiated disturbance measurements EN 55016-2-3:2017/A1:2019/A2:2023 _ Par 5.03 - Variazioni di alimentazione/Supply voltage variations, Par 5.04 - Sovratensione
EN 55016-2-3 Oulu (Yrttipellontie), Salo Specification for radio disturbance and immunity measuring apparatus and methods – Part 2-1: Methods of measurement of disturbances and immunity – Conducted disturbance measurements CISPR 16-2-1 / EN
EN 55016-2-1:2004 + A1:2005 EN 55016-2-1:2009 + A1:2011 EN 55016-2-1:2014 + A1:2017 ISM Equipment EN 55011:1998 + A1:1999 + A2:2002 IT Equipment Laboratory Equipment EN 55011:2007 + A2:2007 Medical/Dental Equipment EN 55011-2009
EN 55016-2-3:2010 including A1:2010 and A2:2014 EN 55016-2-3:2017 EN 55022:2010 EN 55032:2012 EN 55032:2015 including A11:2020 ANSI C63.4:2014 FCC CFR 47: Part 15B FCC CFR 47: Part 18 ICES-001 issue 5 ICES-003 issue 7
EN 55016-2-1:2019-11 (EN 55016-2-1:2014 + A1:2017) Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit – Teil 2-1: Verfahren zur M
EN 55016-2-1, CISPR 16-2-1 EN 55011, CISPR 11 OS EMC.E.03 Electric- and electronic equipment Conducted Emissions Voltage method (LISN) 9 kHz – 30 MHz document 850 EN 55016-2-1, CISPR 16-2-1 EN 55011, CISPR 11 EN 55014-1, CISPR 14
EN 55016-2- 1:2009 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit – Teil 2-1: Verfahren zur Messung der hochfrequenten Störau
EN 55016-1-4:2010/A1:2012/A2:2017, EN IEC 55016-1-4:2019/A1:2020 CISPR 16-1-2:2014/AMD1:2017, EN 55016-1-2:2014/A1:2018 EN 61000-4-13:2002/A1:2009/A2:2016, IEC 61000-4-13:2002/AMD1:2009/AMD2:2 015 Prove di immunità a buchi di tensione, b
Showing labs 51–58 of 58. Use pagination below to see more.