IEC 60601-2-52 Accredited Testing Labs Worldwide
33 accredited laboratories in 7 countries hold IEC 60601-2-52 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle. In the register, IEC 60601-2-52 scope entries most often cover Hardness, Pressure, Radiation, Ionizing/Non-Ionizing in Electrical equipment, Machines and equipment, Medical equipment, electrical safety and EMC.
Available in 7 Countries
Top matrices for IEC 60601-2-52
Top analytes for IEC 60601-2-52
- Hardness (1)
- Pressure (1)
- Radiation, Ionizing/Non-Ionizing (1)
Sample labs
Leistungsmerkmale von Geräten zur Stimulation von Nerven und Muskeln (IEC 60601-2-10:2012 + A1:2016); Deutsche Fassung EN 60601-2-10:2015 + A1:2016 DIN EN 60601-2-18 : 2016-10 Medizinische elektrisch e Geräte - Teil 2-18: Besondere Fes
IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION; IEC 60601-2-54 Edition 2.0 2022-09; ISO 80601-2-55 Second edition 2018-02; ISO 80601-2-55 Second edition 2018-02 [Including AMD1:2023]; IEC 80
IEC 60601-2-52; IEC 60601-2-57; IEC 60601-2-5; IEC 60601-2-7; IEC 80601-2-69; UL 187; UL 60601-1 (excluding Clauses 36, 37, 40, 41, and 44.7) Miscellaneous Electrical Equipment CAN/CSA B149.3; CAN/CSA-C22.2 No. 102; CAN/CSA-
IEC 60601-2-52; IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION; IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-54 (Ed 1.1, Ed 1.2); IEC 60601-2-54 Edition 2.0 2022-09; IEC 60601-2-63; IEC 60601-2-63 Edition 1.2 2021-05 C
DIN EN 60601-2-47:2016-02 Medizinische elektrische Geräte - Teil 2-47: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von ambulanten elektrokardiographischen Systemen (IEC 60601-2-47:2012); De
Department Standard / in house procedure / Version Title of standard or in house procedure (deviaBons /reducBons modificaBons of standard) LocaBon/ reducBons VDE 0750 -2-50: 2022 Product Safety IEC 60601 -2-52:2009 + A1:
Test Technology: Test Method(s)2,3: Medical Equipment (cont.) EN 60601-2-336 (Excluding Cl 201.17, 202); EN 60601-2-34 (Excluding Cl 201.17
IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION; IEC 60601-2-54 Edition 2.0 2022-09; ISO 80601-2-55 Second edition 2018-02; ISO 80601-2-55 Second edition 2018-02 [Including AMD1:2023]; ISO 80
IEC 60601-2-52:2009); Deutsche Fassung EN 60601-2-52:2010 VDE 0750-2-52:2010-12 DIN EN 60601-2-54 : 2020-03 Medizinische elektrische Geräte - Teil 2-54: Besondere Festlegungen für die Sicherheit und die wesentlichen Leistungsmerkmale vo
IEC 60601-2-52 (Ed. 1 + Am 1); IEC 80601-2-26 (Ed. 1 + Am 1); IEC 80601-2-30 (Ed. 1.1, Ed. 2.0); ANSI/AAMI/IEC 80601-2-30:2018; IEC 80601-2-35 (Ed. 1 + Am 1) (excluding cl 201.8.8.4.101); IEC 80601-2-49 (Ed. 1); IEC 80601-2-60 (Ed. 1,
DIN EN ISO 1923 1995-06 Cellular plastics and rubbers - Determination of linear dimensions DD DIN EN ISO 2439 2009-05 Flexible cellular polymeric materials - Determination of hardness (indentation technique) DD DIN
IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION 6-489 IEC 60601-2-52 Edition 1.0 2009-12 6-321 IEC 60601-2-57 Edition 1.0 2011-01 12-242 IEC 61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION 19-34 IEC 60601-1 Edition 3.2 2020-08
IEC 60601-2-52; EN 60601-2-52; CAN/CSA-C22.2 No. 60601-2-52 Part 2-57: Particular Requirements for the Basic Safety and Essential Performance of Non-Laser Light Source Equipment Intended for IEC 60601-2-57; EN 60601-2-57; CAN/CSA-C
IEC 60601-2-52; IEC 60601-2-52:2009; EN 60601-2-52 Medical electrical equipment - Part 2-46: Particular requirements for basic safety and essential performance of operating tables IEC 60601-2-46; EN IEC 60601-2-46 Medical electri
IEC 60601-2-52; EN 60601-2-52; CAN/CSA-C22.2 No. 60601-2-52 X-ray equipment for radiography and radioscopy IEC 60601-2-54; EN 60601-2-54; CAN/CSA-C22.2 No. 60601-2-54 Non-laser light source equipment IEC 60601-2-57; EN 6060
Quellenverzeichnis Regelwerke/Prüfverfahren: DIN EN 1865-1 : 2015-08 Krankentransportmittel im K rankenkraftwagen - Teil 1: Allgemeine Krankentragesysteme und Krankentransportmittel; Deutsche Fassung EN 1865-1:2010+A1:2015 DIN EN ISO 10
IEC 60601-2-52: Edition 1.0 2009-12; IEC 60601-2-57: Edition 1.0 2011-01; IEC 61010-1: Edition 3.1 2017-01; IEC/ANSI/AAMI 60601-1-12; IEC/EN/UL 61010-2-030; CSA C22.2 No. 61010-2-030 Enclosure Integrity IEC 60529; IPX1 and IPX 2
IEC 60601-2-52 : 2009-12 Medical electrical equipme nt - Part 2-52: Particular requirements for basic safety and essential performance of medical beds + Amendment 1: 2015-03 IEC 60601-2-66 : 2015-06 ⊗ Medical electrical equipment - Part
IEC 60601-2-52; EN 60601-2-52; CAN/CSA-C22.2 No. 60601-2-52; IEC 80601-2-59; EN IEC 80601-2-59; CAN/CSA-C22.2 No. 80601-2-59; IEC 80601-2-60; EN IEC 80601-2-60; CAN/CSA-C22.2 No. 80601-2-60; ISO 7494-1; EN ISO 7494-1; ISO
IEC 60601-2-52; EN 60601-2-52; CAN/CSA-C22.2 No. 60601-2-52 Medical electrical equipment – Part 2-54: Particular requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy IEC 60601-2-
IEC 60601-2-52; EN 60601-2-52; DIN EN 60601-2-52; VDE 0750-2-52; IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION Medical electrical equipment − Part 2-54: Particular requirements for
IEC 60601-2-52; IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-52 Edition 1.1 2015-03 Consolidated Version; IEC 60601-2-66; IEC 60601-2-68;
IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION (Section(s) 201.17/202) 1; IEC 60601-2-54 Edition 2.0 2022-09; IEC 60601-2-57 Edition 1.0 2011-01 (Section(s) 201.17/202) 1; IEC 60601-2-57 Edition 2.0 2023-07; IEC 60601-2-6 Edit
Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Medyczne urządzenia elektryczne – stoły operacyjne Trwałość oznakowania Czytelność oznakowania Pomiar napięc
IEC 60601-2-52 (Medical Beds); EN/IEC 60601-2-54 (X-ray Equipment or Radiography and Radioscopy); IEC 60601-2-57 (Non-Laser Light Source Equipment); EN/IEC 60601-2-63 (Dental Extra-oral X-ray Equipment); IEC 60601-2-65 Dental Intra-Oral
Test(s): Test Method(s) 1,2: Medical electrical equipment – Part 2-69: Particular requirements for basic safety and essential performance of oxygen concentrator equipment ISO 80601-2-69; EN ISO 80601-2-69; CAN/CSA-C22.2 No.80601-
IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION (excluding clauses listed in the “Exclusion” table above) 6-489 IEC 61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION (excluding clauses listed in the “Exclusion” table above) 1
Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Medyczne urządzenia elektryczne – łóżka medyczne Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjent
IEC 60601-2-52:2009 + Cor.:2010 + A1:2015); German version EN 60601-2-52:2010 + AC:2011 + A1:2015 DIN EN 60601-2-52 : 2010-12 ⊗ - Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential perfo
IEC 60601-2-52:2009 + A1:20151; EN 60601-2-52:2010 + A1:2015; Respiratory Gas Monitors ISO 80601-2-55:20181; EN ISO 80601-2-55:2018; Clinical Thermometers for Body Temperature Measurement ISO 80601-2-56:20171; EN ISO 80601-2-56:2017;
IEC 60601-2-52:2009); German version EN 60601-2-52:2010 Medical Equipment # IEC 60601 -2-54:2022 Medical electrical equipment - Part 2 -54: Particular requirements for the basic safety and essential performance of X- ray equipment
Test Technology: Test Method(s): Product Safety (Cont’d) AS/NZS 60669.1 (excluding: 22.5, 25); IEC/EN 60669-2-1 (excluding: 22.5, 25); BS
IEC 60601-2-52 Edition 1.0 2009-12 6-321 IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION 6-489 IEC 61010-1 Edition 3.1 2017-01 19-34 ANSI UL 61010-1 3rd Ed, dated May 12, 2012 with revision through July 19, 2019 19-41 IEC 80601