ISO 14708 Accredited Testing Labs Worldwide
ISO 14708, all parts: Implants for surgery - Active implantable medical devices. Each lab card shows which parts it holds.
- ISO 14708-1Part 1: General requirements for safety, marking and for information to be provided by the manufacturer13 labs →
- ISO 14708-2Part 2: Cardiac pacemakers9 labs →
- ISO 14708-3Part 3: Implantable neurostimulators9 labs →
- ISO 14708-4Part 4: Implantable infusion pump systems8 labs →
- ISO 14708-5Part 5: Circulatory support devices2 labs →
- ISO 14708-6Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)5 labs →
- ISO 14708-7Part 7: Particular requirements for cochlear and auditory brainstem implant systems5 labs →
19 accredited laboratories in 7 countries hold ISO 14708 in their accredited scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.
Available in 7 Countries
Sample labs
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, Issue 7; I
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022 Clause 27; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, I
ISO 14708-1; ISO 14708-2; ISO 14708-3; ISO 14708-6; ISO 14708-7; ISO 10079-1; ISO 10079-2; ISO 10079-3; ISO 10079-4; ISO 15004-1; ISO 111976; ISO 151976; ISO 23402-1 (Excluding Cl 5.2.9, 5.5.4); ISO 23402-3 (Excluding Cl 7.5); ISO 536
ISO 14708-1(Ed. 2, Ed. 1); ISO 14708-3 (Ed. 2, Ed. 1); ISO 14708-4 (Ed. 1); (All ISO 14708 standards exclude Cl.14.2 and Cl.22); ISO 80601-2-12 (Ed. 1, Ed. 2, Ed. 3); ISO 80601-2-55 (Ed. 1, Ed. 2 + Am 1); ISO 80601-2-56 (Ed. 1, Ed.2 +
ISO 14708-1, ISO 14708-2 ISO 14708-3, ISO 14708-4 ISO 14708-5, ISO 14708-6 ISO 14708-7 Airborne Particle Testing (APT) SOP 48/F1 ISO 14644-1:2015 ISO 14644-5:2004 ISO 14644-7:2004 ISO 14644-1:1999 ISO 18562-1, ISO 18562-2 A
ISO 14708 -2 : 2019 -09 Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers ISO 14708-2 : 2012-08 ⊗ - Implants for surgery -- Active implantable medical devices -- Part 2: Cardiac pacemakers ISO 14708
ISO 14708-3; TSC-3000G High Temperature2 200 °C MIL-STD-202 E, F, G, (Method 108); MIL-STD-810 Base, A, B, C, D, E, F, G, H, (Method 501); SAE/USCAR 24 (Inflator Requirements) June 2004; SAE/USCAR 28 (Initiator Requirements) June 2
ISO 14708-1:2014 **1,2,4 V 9 kHz - 40 GHz ISO 14708-2:2019 Clause 24 (ESD) and 27 (EMC) V 9 kHz - 40 GHz ISO 14708-3:2017 Clause 24 (ESD) and 27 (EMC) Alarm systems - (Alarm transmission systems and equipment) V See 3
ISO 14708-1 (clause 27 only); ISO 14708-3 (clause 27 only); ISO 14708-7 (clause 27 only); ISO 14117:2019, Sections 4-6; ANSI/USEMCSC C63.27 2021; EN 45502-1 (Section 27); EN 45502-2-1 (Section 27); EN 45502-2-3 (Section 27); ISO 7