ISO 14708 Accredited Testing Labs Worldwide
ISO 14708, all parts: Implants for surgery - Active implantable medical devices. Each lab card shows which parts it holds.
- ISO 14708-1Part 1: General requirements for safety, marking and for information to be provided by the manufacturer13 labs →
- ISO 14708-2Part 2: Cardiac pacemakers9 labs →
- ISO 14708-3Part 3: Implantable neurostimulators9 labs →
- ISO 14708-4Part 4: Implantable infusion pump systems8 labs →
- ISO 14708-5Part 5: Circulatory support devices2 labs →
- ISO 14708-6Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)5 labs →
- ISO 14708-7Part 7: Particular requirements for cochlear and auditory brainstem implant systems5 labs →
19 accredited laboratories in 7 countries hold ISO 14708 in their accredited scope. We don't know yet whether 2 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.
Available in 7 Countries
Sample labs
ISO 14708-4 Ed 2.0 (2022-02) – (only Section 27.103 and Section 27.104); ISO 14708-4 Ed 1.0 (2008-11-15) – (only Section 27.103 and Section 27.104); IEC 80601-2-49:2018 Ed.1.0 (Only Section 202.8.102); IEC 61000-4-9 AEI Issued:03/01/20
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, Issue 7; I
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022 Clause 27; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, I
ISO 14708-1; ANSI/AAMI EC12; ANSI AAMI EC53; ANSI/AAMI EC57; ANSI/AAMI BP22 (Excluding Cl 5.1.2 n); ANSI/AAMI DF80 (Excluding Cl 44.6,36); EN 60601-16 (Excluding Cl 8.8.4.1, 9.7.5, 10.4, 11.6.5, 17); EN 60601-1-36; EN 60601-1-6; E
ISO 14708-1(Ed. 2, Ed. 1); ISO 14708-3 (Ed. 2, Ed. 1); ISO 14708-4 (Ed. 1); (All ISO 14708 standards exclude Cl.14.2 and Cl.22); ISO 80601-2-12 (Ed. 1, Ed. 2, Ed. 3); ISO 80601-2-55 (Ed. 1, Ed. 2 + Am 1); ISO 80601-2-56 (Ed. 1, Ed.2 +
ISO 14708.1; AS 14708.1; IATA PI968; IEC 61243-2; ISO 15003; ISO 16750-4; GMW3172; GMW14650; Ford CETP 00.00-E-412; SAE/USCAR-2; CS.00056
ISO 14708 -5:2022 -12 Implants for surgery - Active implantable medical devices - Part 5: Circulatory support devices (ISO 14708-5:2020); German version EN ISO 14708-5:2022 ISO 18193 : 2021 -08 / AMD1:2025-07 Cardiovascular implants
ISO 14708-1, ISO 14708-2 ISO 14708-3, ISO 14708-4 ISO 14708-5, ISO 14708-6 ISO 14708-7 Airborne Particle Testing (APT) SOP 48/F1 ISO 14644-1:2015 ISO 14644-5:2004 ISO 14644-7:2004 ISO 14644-1:1999 ISO 18562-1, ISO 18562-2 A
ISO 14708-7:2019); Deutsche Fassung EN ISO 14708- 7:2022 DIN EN ISO 21647 : 2009-09⊗ Medizinische elektrische Geräte - Besondere Festlegungen für die grundlegende Sicherheit und grundlegenden Leistungsmerkmale von Überwachungsgeräten für
ISO 14708-1; EN ISO 14708-1 Respiratory equipment - Particular requirements for basic safety and essential performance of infant cardiorespiratory monitors ISO 18778; EN ISO 18778
ISO 14708 -2 : 2019 -09 Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers ISO 14708-2 : 2012-08 ⊗ - Implants for surgery -- Active implantable medical devices -- Part 2: Cardiac pacemakers ISO 14708
ISO 14708-3; TSC-3000G High Temperature2 200 °C MIL-STD-202 E, F, G, (Method 108); MIL-STD-810 Base, A, B, C, D, E, F, G, H, (Method 501); SAE/USCAR 24 (Inflator Requirements) June 2004; SAE/USCAR 28 (Initiator Requirements) June 2
ISO 14708-4 Ed 2.0 (2022-02) – (Only Section 27.103 and Section 27.104); ISO 14708-4 Ed 1.0 (2008-11-15) – (Only Section 27.103 and Section 27.104); IEC 80601-2-49:2018 Ed.1.0 (Only Section 202.8.102); AIM Standard 7351731 Rev. 3.00 20
ISO 14708-1 : 2014-08 Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer ASTM E 3060 – 23 Standard Guide for Subvisible Part
ISO 14708-1:2014 **1,2,4 V 9 kHz - 40 GHz ISO 14708-2:2019 Clause 24 (ESD) and 27 (EMC) V 9 kHz - 40 GHz ISO 14708-3:2017 Clause 24 (ESD) and 27 (EMC) Alarm systems - (Alarm transmission systems and equipment) V See 3
ISO 14708-1 (clause 27 only); ISO 14708-3 (clause 27 only); ISO 14708-7 (clause 27 only); ISO 14117:2019, Sections 4-6; ANSI/USEMCSC C63.27 2021; EN 45502-1 (Section 27); EN 45502-2-1 (Section 27); EN 45502-2-3 (Section 27); ISO 7
ISO 14708-2 : 2022-12 2 Chirurgische Implantate - Aktive implantierbare medizinische Geräte - Teil 2: Herzschrittmacher (ISO 14708 -2:2019); Deutsche Fassung EN ISO 14708-2:2022 DIN EN ISO 7198 : 2017-07 3 Kardiovaskuläre Implantate und
ISO 14708-2: Cl. 23.5 ISO 14708-6: Cl. 23.5 THD-0406-XXXX-0004 EN 45502-2-1: Cl. 23.5 EN 45502-2-2: Cl. 23.5 ISO 14708-2: Cl. 23.5 ISO 14708-6: Cl. 23.5 THD-0406-XXXX-0030 Packaging / Distribution Standard: Clause (Cl.) Internal
ISO 14708-2:2019 punkt 6.1.2 Wersja strony: A