ISO 14708, all parts: Implants for surgery - Active implantable medical devices. Each lab card shows which parts it holds.
- ISO 14708-1Part 1: General requirements for safety, marking and for information to be provided by the manufacturer13 labs →
- ISO 14708-2Part 2: Cardiac pacemakers9 labs →
- ISO 14708-3Part 3: Implantable neurostimulators9 labs →
- ISO 14708-4Part 4: Implantable infusion pump systems8 labs →
- ISO 14708-5Part 5: Circulatory support devices2 labs →
- ISO 14708-6Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)5 labs →
- ISO 14708-7Part 7: Particular requirements for cochlear and auditory brainstem implant systems5 labs →
19 accredited laboratories in 7 countries hold ISO 14708 in their accredited scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.
Available in 7 Countries
Sample labs
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, Issue 7; I
ISO 14708-1 (2014) clause 27; ISO 14708-3 (2017-04) clause 27; ISO 14708-4 (2008-11-15) clause 27; ISO 14708-4:2022 Clause 27; EN 60945 (2002) [excluding clauses 8 and 11]; IEC 60945 (2002) [excluding clauses 8 and 11]; GR-1089-CORE, I
ISO 14708-1; ANSI/AAMI EC12; ANSI AAMI EC53; ANSI/AAMI EC57; ANSI/AAMI BP22 (Excluding Cl 5.1.2 n); ANSI/AAMI DF80 (Excluding Cl 44.6,36); EN 60601-16 (Excluding Cl 8.8.4.1, 9.7.5, 10.4, 11.6.5, 17); EN 60601-1-36; EN 60601-1-6; E
ISO 14708-1(Ed. 2, Ed. 1); ISO 14708-3 (Ed. 2, Ed. 1); ISO 14708-4 (Ed. 1); (All ISO 14708 standards exclude Cl.14.2 and Cl.22); ISO 80601-2-12 (Ed. 1, Ed. 2, Ed. 3); ISO 80601-2-55 (Ed. 1, Ed. 2 + Am 1); ISO 80601-2-56 (Ed. 1, Ed.2 +
ISO 14708-1, ISO 14708-2 ISO 14708-3, ISO 14708-4 ISO 14708-5, ISO 14708-6 ISO 14708-7 Airborne Particle Testing (APT) SOP 48/F1 ISO 14644-1:2015 ISO 14644-5:2004 ISO 14644-7:2004 ISO 14644-1:1999 ISO 18562-1, ISO 18562-2 A
ISO 14708-1 : 2014-08 Chirurgische Implantate - Teil 1: Allgemeine Festlegungen für die Sicherheit, Aufschriften und vom Hersteller zur Verfügung zu stellende Informationen ISO 14708-4 : 2008-11⊗ Chirurgische Implantate - Aktive implan
ISO 14708-1; EN ISO 14708-1 Respiratory equipment - Particular requirements for basic safety and essential performance of infant cardiorespiratory monitors ISO 18778; EN ISO 18778
ISO 14708 -1 : 2014 -08 Implants for surgery -- Active implantable medical devices -- Part 1: General requirements for safety, marking and for information to be provided by the manufacture ANSI/AAMI/ISO 14708-1:2014
ISO 14708-1 : 2014-08 Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer ASTM E 3060 – 23 Standard Guide for Subvisible Part
ISO 14708-1:2014 **1,2,4 V 9 kHz - 40 GHz ISO 14708-2:2019 Clause 24 (ESD) and 27 (EMC) V 9 kHz - 40 GHz ISO 14708-3:2017 Clause 24 (ESD) and 27 (EMC) Alarm systems - (Alarm transmission systems and equipment) V See 3
ISO 14708-1 (clause 27 only); ISO 14708-3 (clause 27 only); ISO 14708-7 (clause 27 only); ISO 14117:2019, Sections 4-6; ANSI/USEMCSC C63.27 2021; EN 45502-1 (Section 27); EN 45502-2-1 (Section 27); EN 45502-2-3 (Section 27); ISO 7
ISO 14708-1 Prüfung der Anforderungen - Ermüdungsbe- ständigkeit von Fixierungselementen implantierbarer Leadless Pacemaker ASTM F 3211 ISO 14708-1 ISO 14708-2 DIN EN ISO 25539-1 RW-07
ISO 14708-1 Cl. 17.1 ISO 14708-2 Cl. 17.1 ISO 14708-6 Cl. 17.1 EN 45502-1 Cl. 17.1 EN 45502-2-2 Cl. 17.1 10086577DOC ISO 14708-6 Cl. 19.2 EN 45502-2-2 Cl. 19.2 10169463DOC ISO 14117 Cl. 6.2 ISO 14708-1 Cl. 20 EN 45502-1 Cl. 20 EN