FindTestingLabs
Registers collected 2026-08-22.See collection dates
ISO/IEC 17025 directory

ASTM G155 Accredited Testing Labs in United States

16 laboratories in United States are accredited by A2LA under ISO/IEC 17025 to perform ASTM G155 testing. From the accredited scope text: “ASTM G155 ASTM G155 Standard practice for operating xenon arc light apparatus for exposure of non-metallic materials ICC ES AC212 Water-resistive coatings used as water-resistive barriers over exterio” “ASTM G155 Standard Practice for Operating Xenon Arc Lamp Apparatus for Exposure of Materials CAN/CGSB-12.1 Safety Glazing CPSC 16 CFR 1201 Safety standard for architectural glazing materials DASMA 108” “ASTM G155 Operating Xeon Arc Light Apparatus for Exposure of Non-Metallic Materials” “ASTM G155 Standard Test Methods for Measuring Adhesion by Tape Test ASTM D3359 Standard Practice for general Techniques for Obtaining Infrared Spectra for Qualitative Analysis/FT-IR Test for Lubricant”

Labs
16
Primary AB
A2LA16 labs

Accredited Labs

Element Materials Technology Minneapolis

Minneapolis, MN, US

Scope

ASTM G155; GR-487-CORE; IEC 60945, Section 8.10; IEC 60068-2-5; SAE J2527; UL 746C; UL 1581; MIL-STD-810, Method 505

View lab

Element Broken Arrow

Broken Arrow, OK, US

Scope

Test Test Method(s) Metallographic Evaluation (cont’d) Microhardness Knoop (100 to1000) gf ASTM B578, E92, E384, F606/F606M; NASM 1312-6; NAVSEA S9074-GIB-010/248 Vickers (100 to 1000) gf ASTM B578, E92, E384, F606/F60

View lab

Nelson Testing

Elmhurst, IL, US

Scope

ASTM G155 Operating Xeon Arc Light Apparatus for Exposure of Non-Metallic Materials

View lab

Michigan Testing Institute

Sterling Heights, MI, US

Scope

ASTM G155, ASTM D7869; FORD FLTM BN117-03; FLTM BO 116-01; GM 9125P (3.3) (Inactive 5/13); GMW 14162 Method D; HYUNDAI MS210-05 (4.5); MS700-60 (4.20); ISO 105-B06; NES M0135 (II), NES M0007 (2014-1) (48), NES M0141 (6.4.1); RIVIA

View lab

Intertek Testing Services NA

Duluth, GA, US

Scope

ASTM G155; IEC 61827; ATPD-2352T, Section 4.3.5 Yield Device FAA AC 150/5345, -27, -28, -39, -44, -46, -51; IEC 61827, ICAO Design Manual Part 6, TP-312 Personal Protective Equipment (PPE) Standard Performance Specification for Newl

View lab

NSF International

Ann Arbor, MI, US

Scope

ASTM G155 Standard Test Methods for Measuring Adhesion by Tape Test ASTM D3359 Standard Practice for general Techniques for Obtaining Infrared Spectra for Qualitative Analysis/FT-IR Test for Lubricants ASTM E1252/NSF 8182 Standard Test

View lab

Aerospace Testing Services

Norman, OK, US

Scope

ASTM G155; MIL-PRF-85285-E, Section 4.6.9 Balanced Beam Scrape Adhesion ASTM D2197 Pull Off Adhesion (PATTI) ASTM D4541, D7234; ISO 4624, 16276-1 Construction Weight AMS3819 – 3.1, 3.6.1; ASTM D3776M Color/Cleanliness AMS3819 –

View lab

Element Materials Technology Chicago - Mt. Prospect

Mount Prospect, IL, US

Scope

ASTM G155; EN ISO 4892-2 1 Including customer supplied and industry specifications directly related to the test technologies and parameters listed above.

View lab

Ghesquiere Plastic Testing

Harper Woods, MI, US

Scope

ASTM G155; CFFA-2 Method a and b; Fiat 50451/01 (Method A); Ford FLTM BN 017-02, FLTM BN 117-01, FLTM BN 117-03, FLTM BO 116-01; GM9125P (1991); GMW14162 (Method D); ISO 105-B06 (Procedure 5), ISO 4892-1, ISO 4892-2; Nissan NES

View lab

Element Materials Technology Seattle

Bothell, WA, US

Scope

ASTM G155; ASTM D2565 Dust IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1 Settling Dust IEC 60529, Section 13 Blow

View lab

Intertek Testing Services NA

Kentwood, MI, US

Scope

ASTM G155 ASTM G155 Standard practice for operating xenon arc light apparatus for exposure of non-metallic materials ICC ES AC212 Water-resistive coatings used as water-resistive barriers over exterior sheathing (test methods reference

View lab

Assured Testing Services

Ridgway, PA, US

Scope

ASTM G155; Ford BO 116-01; ISO 4892-2; ISO 16474-2; Navistar MPAPS GT-31 (Methods A&B); Nissan NES M0007 (Method 48- 48.6.3); SAE J2412; SAE J2527 1 This laboratory also uses customer supplied specifications directly related to t

View lab

ICC Evaluation Service

Nappanee, IN, US

Scope

ASTM G155 Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials ASTM G195 Standard Guide for Conducting Wear Tests Using a Rotary Platform Abraser AWPA E12 Standard Method of Determining Co

View lab

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA

Santa Clara, CA, US

Scope

ASTM G155; ISO 4892-1; UL 746C Temperature Cycling High / Low Temperature GR-63; GR-487; IEC 60068-2-1; IEC 60068-2-14; IEC 60068-2-2; RTCA/DO-160 Sections 4.0 and 5.0; MIL-STD-810 Methods 501 and 502; MIL-STD-202 Method 108; MIL

View lab

Architectural Testing, Inc. (An Intertek Company)

Farmingdale, NY, US

Scope

ASTM G155 Standard Practice for Operating Xenon Arc Lamp Apparatus for Exposure of Materials CAN/CGSB-12.1 Safety Glazing CPSC 16 CFR 1201 Safety standard for architectural glazing materials DASMA 108 Standard Method For Testing Sec

View lab

Element Materials Technology St. Paul

St. Paul, MN, US

Scope

Test(s): Test Method(s): Environmental Simulation: Humidity MIL-STD-202 (Method 103B), MIL-STD-810 (Method 507) Fluorescent UV- Condensation, Light- and Water-Exposure (QUV) ASTM G154 Salt Spray (Fog) ASTM B117; MIL-STD-202

View lab
Refine these results

This page is a fixed slice of the register: every ASTM G155 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United States

Top matrices for ASTM G155 in United States

Top analytes for ASTM G155 in United States

  • Compressive Strength1
  • Density1
  • Hardness1
  • Weight Loss1

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches