IEC 61000-4-6 Accredited Testing Labs Worldwide
176 accredited laboratories in 13 countries hold IEC 61000-4-6 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body. In the register, IEC 61000-4-6 scope entries most often cover Impedance, Frequency, Harmonics in Air, Electronic, Medical equipment, electrical safety and EMC.
Available in 13 Countries
Top matrices for IEC 61000-4-6
Top analytes for IEC 61000-4-6
- Impedance (5)
- Frequency (2)
- Harmonics (2)
- Insertion Loss (2)
- Emissions (Radiated And Conducted) (1)
- Coupling Factor (1)
- Emissions (1)
- Harmonic Current Emissions (1)
Sample labs
IEC 61000-4-6:2013) EMV DIN EN 61000-4-8:2010 (EN 61000-4-8:2010) Elektromagnetische Verträglichkeit (EMV) – Teil 4-8: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen Magnetfelder mit energietechnischen Frequenzen (IEC 6
IEC 61000-4-6; IEC 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8 Voltage Dips, Short Interruptions, And Line Voltage Variations EN IEC 61000-4-11; IEC 61000-4-11
IEC 61000-4-6:2013; ISO 11452-4:2011 Voltage Dips, Short Interruptions and Voltage Variations IEC 61000-4-11:2020; RTCA/DO-160E:2004 (Section 16); RTCA/DO-160F:2007 (Section 16); RTCA/DO-160G:2010 (Section 16) Electrical Fast Tra
IEC 61000-4-6:2023; EN IEC 61000-4-6:2023; IEC 61000-4-6; EN IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test IEC 61000-4-8:2009; EN 610
IEC 61000-4-6; BS EN 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variations EN 61000-4-11; IEC 61000-4-11; BS EN 6100
IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6;
Parameter/Equipment Frequency CMC2, 4, 7 (±) Comments RF Insertion Loss3 – (cont) EM Clamps: Impedance Coupling Factor Decoupling Factor Decoupling Clamps: Impedance Decoupling Factor LISN, AN, AMN (Voltage D
IEC 61000-4-6:2013-10 /AC1:2015-06 Corrigendum 1 - Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EMV IEC 61000-4-6:2013-10
IEC 61000-4-6 WO EMC.I.07 Immunity to conducted disturbances Induced by radio- frequency fields Up to 10 Vrms 150 kHz - 80 MHz document 903 Equivalent to EN / IEC 61000-4-6 WO, OS EMC.I.12 Radiated Immunity Electric Field Up to
Test: Test Method(s) 1: Radiated and Conducted Emissions (9 kHz to 40 GHz) (continued) Japan VCCI-CISPR 32; J55011; J55014-1 (excluding clicks); J55015; J55022; J55032 Taiwan CNS 13438; CNS 13439; CNS 13783-1 (excluding c
IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dip & Interrupt IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11 Generic or P
IEC 61000-4-6; BS EN 61000-4-6
IEC 61000-4-6:2013); Deutsche Fassung EN 61000-4-6:2014 Kap. 6.2.4 ohne direkte Einkopplung EMV DIN EN 61000-4-8 VDE 0847 Teil 4-8: 2010 (EN 61000-4-8) Elektromagnetische Verträglichkeit (EMV)- Teil 4-8: Prüf und Messverfahre
IEC 61000-4-6; KN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variations IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-6:2014+A1:2017; IEC 61000-4-6; IEC 61000-4-6:2013+AMD1:2017; SANS 61000-4-6; KS C 9610-4-6; KS C 9610-4-6:2023; Power Frequency Magnetic Field EN 61000-4-8(excluding short duration mode); EN IEC 61000-4-8:2010; IEC 610
IEC 61000-4-6; IEC 61000-4-6:2023; IEC 61000-4-6:2013; IEC 61000-4-6:2008; IEC 61000-4-6:2003 + A1:2004 + A2:2006; JIS C 61000-4-6:2006; JIS C 61000-4-6:2017; SANS 61000-4-6:2017 Testing and Measurement Techniques - Power Frequen
IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6 Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interrupts, and Variations IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11 Ge
Normative document: EN ISO/IEC 17025:2017 Registration number: L 015 of Kiwa Nederland B.V. Kiwa FSS Testing This annex is valid from: 29-01-2026 to 01-09-2028 Replaces annex dated: 28-01-2026 Dutch Accreditation Council RvA
IEC 61000-4-6:2013) Deutsche Fassung EN 61000-4-6:2014 EMV DIN EN 61000-4-8:2010-11 VDE 0847-4-8:2010-11 Elektromagnetische Verträglichkeit (EMV) - Teil 4-8: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Magnetfelder m
Tests: Test Method(s) 1: Immunity Electrostatic Discharge (ESD) IEC/EN 61000-4-2; KS C 9610-4-2; RTCA/DO-1602 D, E, F, & G (Section 25); MIL-STD-1686; MIL-STD-461G (CS118) Radiated Immunity IEC/EN 61000-4-3; KS C 9610-4-3; RT
IEC 61000-4-6; IEC 61000-4-6:2008 Power Frequency and Magnetic Field IEC 61000-4-8 (Excluding Short Duration Mode) Voltage Dip, Interruptions, and Variations IEC 61000-4-11
IEC 61000-4-6; KN 61000-4-6; KS C 9610-4-6; SANS 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; KN 61000-4-8; KS C 9610-4-8; SANS 61000-4-8 Pulse Magnetic Field Immunity EN 61000-4-9; IEC 61000-4-
IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8 Voltage Dips, Short Interrupts, and Line Voltage Variations IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11
IEC 61000-4-6; EN 61000-4-6 Power frequency magnetic field immunity (PFMF) BS EN 61000-4-8; EN 61000-4-8; IEC 61000-4-8
IEC 61000-4-6 Agilent VNA E5061B
IEC 61000-4-6; KS C 9610-4-6; CNS 14676-6 Power Frequency Magnetic Immunity EN 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; CNS 14676-8 Voltage Dips, Short Interruptions and Voltage Variations EN 61000-4-11; IEC 61000-4-11; KS C 9610-
Showing labs 151–176 of 176. Use pagination below to see more.