ISO 16750-2 Accredited Testing Labs Worldwide
80 accredited laboratories in 12 countries hold ISO 16750-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body. In the register, ISO 16750-2 scope entries most often cover Withstand Voltage, Current, Dc Voltage in Metal.
Available in 12 Countries
Top matrices for ISO 16750-2
Top analytes for ISO 16750-2
- Withstand Voltage (2)
- Current (1)
- Dc Voltage (1)
- Output Voltage (1)
- Radio-Noise Emissions (1)
- Ac Current (1)
- Voltage (1)
- Voltage Accuracy (1)
Sample labs
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Umgebungsbedingungen (ISO 13766 - 1:2018) EMV ISO 13766 -2: 2018 -04 Erdbaumaschinen und Baumaschinen
ISO 16750-2; ISO 6722; ISO 14572; ISO 19642; GMW 3172; GMW 3191; GMW 17136;VW 80000; VW 80106; VW 60306; VW 60360-1; VW 75174; VW 80332; VW 75210; B21 7050; B21 7130; IEC/EN 60512-2-1; IEC/EN 60512-2-2; IEC/EN 60512-3-1; MBN 1
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical field Standard / In-house procedure / Version Title of standard or in house procedure (deviations / mod
ISO 16750-2:2012 Straßenfahrzeuge - Umgebungsbe dingungen und Prüfungen für elektrische und elektronische Ausrüstungen – Teil 2: Elektrische Belastungen; 2012 EMV DIN EN 55012:2010 EN 55012 Fahrzeuge, Boote und von Verbrennungsmoto
ISO 16750-2:2012 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen für elektrische und elektronische Ausrüstungen - Teil 2: Elektrische Beanspruchungen Ohne Prüfung nach Kapitel 4.11, 4.12 EMV ISO 11451-2:2015 Straßenfahrzeuge
ISO 16750-2 Stripline ISO 11452-5 Emissions Radiated and Conducted (3m Semi-anechoic chamber, up to 40 GHz) 47 CFR, FCC Part 15 B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using FCC MP-5:1986); ICES-001; ICES-003; ICE
ISO 16750-2; GB/T 21437.3; GB/T 28046.2; SAE J1113-12 Harmonic Emissions IEC 61000-3-2; EN 61000-3-2; GB 17625.1 Voltage Fluctuations and Flicker IEC 61000-3-3; EN 61
ISO 16750-2; JASO D001-94 Product Family / Generic Standard IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; SANS 61000-6-2; IEC 61000-6-3; EN 61000-
ISO 16750-2; SAE J1113-11, 12; ES 96200-00; RNDS-C-00517; ETSI EN 301 489-1 (7637-2(2004) only) Magnetic Field Immunity SAE J1113-22; ISO 11452-8; ES 96200-00; RNDS-C-00517 1 The laboratory is only accredited for testing acti
ISO 16750-2; GB/T 28046.2; VW VW80000; Jaguar JLR-EMC-CS-2010; Jaguar JLR-EMC-CS; GMW3172; Ford EMC-CS-2009.1; Ford FMC1278; BMW GS-95003-2; BMW GS-95024-2-1; Daimler MBN LV 124-1; Nissan 28401NDS02; Dong Feng EQC-1204; Dong F
ISO 16750-2:2012; ISO 16750-2:2023 Conducted Immunity (CCC and ICC tests and DCC tests) ISO 7637-3:2007 (sections 3, 4); ISO 7637-3:2016 (sections 3, 4); GB/T 21437.3-2012 (sections 3, 4); GB/T 21437.3-2021 (sections 4, 5, Annex
ISO 16750-2; ISO 16750-2 (2012, 2023) Electrical Transients on Supply Lines ISO 7637-2; ISO 7637-2 (2004, 2011) (Supply Lines only) Electrical Transients other than Supply Lines ISO 7637-3; ISO 7637-3 (2007, 2016) (Capacitive & Ind
ISO 16750-2 Transient Conduction and Coupling Definitions and General Considerations ISO 7637-1 Electromagnetic Compatibility General Information SAE J1113-1 Vehicle Electrical/electronic Sub-assembly Electromagnetic Compatibili
ISO 16750-2 (excluding section 4.10.3); GB 34660 (section 4.8); GB 26149 (section 5.1); GB/T 21437.3; GB/T 22630 (section 6.3); GB/T 30513 (section 4.3.2.1); GB/T 36282 (sections 4.2.2 and 5.2.2) Absorber Lined Shielded Enclosu
ISO 16750-2; FMC 1278; CI 222/CI 210/CI 230/CI 231/CI 250/ CI 260/CI 270; GMW3172, Section 9.2 Environmental Cold IEC 60068-2-1 Dry Heat (up to +500 °C) IEC 60068-2-2 Temperature Change (up to 15ºC/min) IEC 60068-2-14
ISO 16750-2:2023 Tecnica di prova O&I _ Par 15.02 - Prova funzionale/Functional test, Par 15.04 - Freddo (prove di funzionamento)/Cold (operational), Par 15.05 - Caldo umido, regime stazionario (prova funzionale)/Damp heat, steady state
ISO 16750-2; BS ISO 16750-2
ISO 16750-2; GB/T 28046.2 Overvoltage ISO 16750-2; GB/T 28046.2 Superimposed Alternating Voltage ISO 16750-2; GB/T 28046.2 Slow Decrease and Increase of Supply voltage ISO 16750-2; GB/T 28046.2 Discontinuities in Supply V
ISO 16750-2 2023-07 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen für elektrische und elektronische Ausrüstungen - Teil 2: Elektrische Beanspruchungen ohne Kap. 4.13 Umwelt- simulation ISO 16750-3 2023-07 Straßenfahrzeuge
ISO 16750-2 Product EMC Standards IEC 61547; EN IEC 61547; BS EN IEC 61547; CISPR 14-2; EN IEC 55014-2; BS EN IEC 55014-2; IEC 61000-6-1; EN IEC 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6
ISO 16750-2:2023-07 Road vehicles – Environmental conditions and testing for electrical and electronic equipment – Part 2: Electrical loads EMV DIN EN 55025:2023 (EN 55025:2022) Fahrzeuge, Boote und von Verbrennungsmotoren angetri
ISO 16750-2 2012-11 Road vehicles – Environmental conditions and testing for electrical and electronic equipment – Part 2: Electrical loads ISO 16750-3 2012-12 Road vehicles – Environmental conditions and testing for electric
Parameter/Equipment Range CMC2, 5, 7 (±) Comments12 Time Interval & Frequency (cont)3 – Surge Generator: Open & Short Circuit Front Time, Rise Time Time to Half Value, Duration Open Circuit Ph
ISO 16750-2) Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details _ _ Elettrodomestici/Household and similar electrica
ISO 16750-2:2012-11 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads EMV DIN EN 55025 VDE 0879-2:2008 (EN 55025) Fahrzeuge, Boote und von Verbrennungsmotoren an
Test(s): Test Method(s): Measuring Compressive Properties of Thermal Insulations ASTM C165 Breaking Load and Flexural Prop. of Block- Type Thermal Insulation ASTM C203 Cellulose Fiber Insulating Board ASTM C209 (Except Flame
ISO 16750-2; ISO 16750-2 (2023); ISO 16750-2 (2012); ISO 16750-2 (2006) Electrostatic Discharge (ESD) ISO 10605; ISO 10605 (2023); ISO 10605 (2008) + A1 (2014); ISO 10605 (2008) (except Annex F); ISO 10605 (2001) RF Immunity to
ISO 16750-2:2012-11 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen für elektrische und elektronische Ausrüstungen - Teil 2: Elektrische Beanspruchungen
ISO 16750-2 (Sections 4.4, 4.6.3 & 4.6.4) Harley Davidson Component EMC Engineering Guideline EG-812-22614 United Nations UNECE Emissions E/ECE/324 Addendum 9: Regulation 10, Annexes 7 and 8 Immunity E/ECE/324 Addendum
ISO 16750-2 (Sections 4.3, 4.4, 4.5, 4.6, and 4.7)
Showing labs 51–80 of 80. Use pagination below to see more.