FindTestingLabs
Registers collected 2026-08-22.See collection dates

ISO 16750-2 Accredited Testing Labs Worldwide

80 accredited laboratories in 12 countries hold ISO 16750-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body. In the register, ISO 16750-2 scope entries most often cover Withstand Voltage, Current, Dc Voltage in Metal.

Total labs
80
Countries
12

Available in 12 Countries

Germany
25 labs
China
18 labs
United States
14 labs
Japan
8 labs
Italy
4 labs
Taiwan
4 labs
South Korea
3 labs
France
1 lab
Spain
1 lab
United Kingdom
1 lab
Sweden
1 lab
Singapore
1 lab

Top matrices for ISO 16750-2

Top analytes for ISO 16750-2

  • Withstand Voltage (2)
  • Current (1)
  • Dc Voltage (1)
  • Output Voltage (1)
  • Radio-Noise Emissions (1)
  • Ac Current (1)
  • Voltage (1)
  • Voltage Accuracy (1)

Sample labs

UL Japan
Ise-shi, Mie, JP

ISO 16750-2 (Sections 4.6.3 and 4.6.4 only) Vehicle and Machinery Standards ISO 13766-1; EN ISO 13766-1; ISO 13766-2; ISO 14982; EN ISO 13766-2 (except ISO 11452-5, ISO 12100, ISO 12630, ISO 13849, and ISO 15998); EN 14982 (exc

TÜV Rheinland (Guangdong) Ltd. EMC-Lab
China, DE

ISO 16750-2:2006* Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads Auto- motive ISO 16750-2:2012* Road vehicles Environmental conditions and testing for electrical an

LabSure Testing Services (Tianjin) Co.,Ltd.
Tianjin, CN

ISO 16750-2:2012; ISO 16750-2 (2023); Ford ES-XW7T-1A278-AA

E & C Testlab GmbH (Engineering & Certification Testlab GmbH)
Trossingen, DE

ISO 16750-2: 2012-11 Fourth edition Road vehicles – Environmental conditions and testing for electrical and electronic equipment – PART 2 loads EMV UN ECE R10 REV. 6 + Amendment 1 30.10.2020 R 10 Uniform provisions concerning t

The EMC Shop
Rocklin, CA, US

ISO 16750-2 Oscilloscope, voltage probe, digital multimeter Automotive-Transient Pulse Simulators Road Vehicles – Electrical Disturbanes Conduction & Coupling Voltage Rise Time Duration Up to 600

TUV ITALIA
Volpiano, IT

ISO 16750-2:2023 Tecnica di prova O&I _ Denominazione della prova / Campi di prova Metodo di prova Tecnica di prova O&I Emissioni elettromagnetiche irradiate/Radiated emission Prove di immunità ai campi elettromagnetici irradiati/R

Sporton International Inc. (Kunshan)
Jiangsu Province, CN

ISO 16750-2 Absorber Lined Shielded Enclosure (ALSE) RF Immunity (80 MHz to 6 GHz) Up to 200 V/m (Metallic Bench Only) Up to 600 V/m (Radar Pulse Only) ISO 11452-2; E/ECE/324/Add. 9 R10 (section 6.8) TEM Cell RF Immuni

PID test & engineering
Sand am Main, DE

ISO 16750-2: 2023-07 Road vehicles — Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads Without Ch. 4.13 (EMV) Elektrische Prüfungen IEC 60512-2-1: 2002-02 Connectors for elect

UL Japan, Inc. - Kashima EMC
Chiba-ken, 289-0341, JP

ISO 16750-2:2012, ISO 16750-2, JASO D 001 Standard equipment: oscilloscope

Bauteilprüfzentrum Scheller
Schweinfurt, DE

ISO 16750-2 2012-11 [Flex A] Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads 4.11 Withstand voltage 4.12 Insulation resistance Elektrotechnik ISO 16750-2 202

TUV Rheinland (Guangdong)
Guangzhou, Guangdong, CN

ISO 16750-2; ISO 21498-2; GB/T 28046.2; VW 80300; VW 80303 Current Harmonics GB 17625.1; IEC 61000-3-12; IEC 61000-3-2

TOYO Corporation Calibration Laboratory
Tokyo 103-8284, JP

Parameter/Equipment5 Range CMC2, 12, 13,14 (±) Comments6 Time Interval & Frequency3 (cont) – Voltage Transient Emission3 Switching Time Transient Immunity3 Surge Pulse & Load Dump Pulse Rise Time Dur

TÜV Rheinland LGA Products
Nürnberg, DE

ISO 16750-2 2012-11 Ed. 4.0 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical Loads ISO 7637-2 2011-03 Ed. 2.0 Straßenfahrzeuge - Elektrische, leitungsgeführte und

Element Materials Technology Detroit – Warren 11 Mile
Warren, MI, US

ISO 16750-2 Road Vehicles – Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical loads (excluding Clause 4.13 Electromagnetic Compatibility) Battery Testing DOE/ID-11069 Ineel Battery Test Man

SGS-CSTC Standards Technical Services (Shanghai) Co.,
Xinqiao, Songjiang, Shanghai, CN

ISO 16750-2; GB/T 21437.3; GB/T 28046.2; SAE J1113-12 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a per

CSA Group Korea
Yongin-si, KR

ISO 16750-2 (2012); Hyundai/Kia ES 96200-00; ECE R10.07 Stripline Test (Immunity) ISO 11452-5 1When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediate

EMTEK (Shenzhen) Co.,
Shenzhen, US

ISO 16750-2; GB/T 28046.2

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE

ISO 16750-2:2012 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 2: Electrical loads EMV ISO 21780:2020 Road vehicles — Supply voltage of 48 V — Electrical requirements and tests

Advanced Test Equipment
San Diego, CA, US

ISO 16750-2, UL1449, GR1089 Tektronix TDS5104 w/high voltage deferential probe & current probe Flicker & Harmonics – Measure Voltage Fluctuations (Flicker) Mains Harmonic Emissions 230V, 50 Hz

CSA Group Bayern
Plattling, DE

ISO 16750-2:2012 Road Vehicles – Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads EMV ISO 16750-2:2023 Road Vehicles – Environmental conditions and testing for electrical and electr

Bureau Veritas Consumer Products Services Germany
Schwerin, DE

EMV ISO 7637 -2:2011 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMV ISO 7637 -3:2016 Road vehicles - Electrical disturbances from c

SOPEMEA TESTING LABORATORY SERVICES
TOULOUSE, FR

ISO 16750-2 / Electrical loads Load dump (Pulse 5b) Oscilloscope, Transient generator, Voltage probe, Resistor Time (s) Voltage (V)

Compliance Management Group (CMG)
Marlboro, MA, US

ISO 16750-2 Emissions Harmonics and Flicker EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; SANS 61000-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; SANS 61000-3-3 Conducted (Excluding Broadcast Receivers)

Molex CVS Bochum GmbH Molex CVS
Bochum, DE

ISO 16750-2: 2012 ISO 16750-2: 2023 Road vehicles -- Environmental conditions and testing for electrical and electronic equipment -- Part 2: Electrical loads EMV ANSI C63.4:2014 American National Standard for Methods of Measureme

GRG Metrology & Test Group Co.,
Shenzhen, CN

ISO 16750-2 (excluding ISO 11451, ISO 11452-3/5/10 and CISPR 12)

UL LLC
Novi, MI, US

ISO 16750-2; GMW 3172 Sections 8.2 & 9.2 Radiated & Conducted Emissions (Unintentional) 47 CFR FCC Part 15, Subpart B (using ANSI C63.4-2014); ICES-003 Radio (Unlicensed Intentional Radiators) 47 CFR, FCC Part 15, Subpa

UL Japan, Inc. Automotive Technology Center
Miyoshi-shi, Aichi, JP

ISO 16750-2 Tri-Plate Line Method SAE J1113-25 Emissions Radiated ANSI C63.4 (up to 18 GHz) Conducted ANSI C63.4 (150 kHz to 30 MHz); CISPR 16-2-1 (Measurements with AMN only, continuous disturbances only) Harmonics UN

DEKRA Certification
Plymouth, MI, US

ISO 16750-2 (2023); ISO 16750-2 (2010, 2012); ISO 16750-2; SAE J1113-13 Automotive Electrical Tests of the following types: Test(s): Test Method(s) 1: - Jump Start - Reverse Polarity - Over Voltage - State Change Waveform Ch

Ametek Singapore Pte Ltd. (Compliance Test Solutions)
Singapore, SG

ISO 16750-2 II. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 4, 6 (±) Comments RF Power3 – Measure 9kHz to 7 GHz (-70 to +20) dBm 0.3 dB Spectrum Anal

TUV SUD America - Plymouth
Plymouth, MI, US

ISO 16750-2 (2010, 2012) * Also using customer-specified methods related to the types of tests listed above.

TELUS-Testlabor für Umweltsimulation
Bissingen an der Teck, DE

Prüfungen in den Bereichen: ausgewählte elektrische Messungen Innerhalb der mit * gekennzeichneten Akkreditierungsbereiche ist dem Prüflaboratorium, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die Anwendu

Element Materials Technology Fremont Newark
Fremont, CA, US

ISO 16750-2; UNECE Regulation 10, Revision 6, Electronic Sub-assemblies (ESA), Sections 6.7, 6.9, 7.17, 7.19 Wireless (Excluding HAC & SAR) ANSI/TIA 603-E; EN 300-113; EN 300 220-1; EN 300 220-2;

HCT CO.,
Icheon-si, Gyungki-do, KR

Parameter/Equipment Range CMC2 (±) Comments RF Speed Guns – Speed (5 to 1000) m/s 0.09 m/s Agilent 33210A, HP 53152A, NSI-MI Technologies MI-210-26A Surge Generators3 – Voltage

Element Materials Technology Straubing GmbH Element Materials Technology Straubing
Straubing, DE

ISO 16750-2:2012-11 Edition 4 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads Keine Prüfungen nach Abschnitt 4.6.4

TÜV SÜD Product Service
Frankfurt/Main, DE

ISO 16750-2:2012 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen für elektrische und elektronische Ausrüstungen - Teil 2: Elektrische Beanspruchungen Road vehicles - Environmental conditions and testing for electrical and elect

EMC Services Elmiljöteknik
Mölndal, SE

ISO 16750-2: 2012 Range 12VDC - 24VDC, Level I - IV Fordonskomponenter Nej Only testing of starting profile 4.6.3 and load dump 4.6.4 ISO 7637-3: 2016 Range 12VDC - 24VDC, Level I - IV Fordonskomponenter Nej Only test method CCC and IC

Institute for International Product Safety
Bonn, DE

Fachbereich Norm oder Hausverfahren / Ausgabestand Titel der Norm oder des Hausverfahrens Einschränkungen zum Prüfverfahren Automotive Components ISO 8820 -5:2015 Road vehicles - Fuse -links - Part 5: Fuse-links with axial term

IMQ SpA
Milano, IT

ISO 16750-2) Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Vedere elenco dei dettagli delle prove flessibili/See

Intertek Deutschland
Kaufbeuren, DE

ISO 16750-2:2012 Strassenfahrzeuge – Umgebungsbedingungen und Prüfungen von elektrischer und elektronischer Ausrüstung – Teil 2: Elektrische Beanspruchung. Verfahren von ausländischen Normungsorganisationen EMC / Radio IEEE ANSI C63

Reliable Analysis (Shanghai)
Shanghai, 201319, CN

ISO 16750-2; MBN 10567; GS 95024-2 Section 7.1~7.26 Road vehicles — Supply voltage of 48 V — Electrical requirements and tests ISO 21780 1 When the date, edition, version, etc. is not identified in the scope of accreditatio

TUV SUD Certification and Testing (China) Co., Ltd. Shanghai Branch
Shanghai, CN

ISO 16750-2; Magnetic Field Immunity ISO 11452-8 (excluding Helmholtz Coil method) Conducted and Transient Immunity ISO 7637-2; ISO 7637-3; Conducted and Transient Immunity ISO 13766-1; EN ISO 13766-1; ISO 13766

OHTAMA CALIBRATION SERVICE Co.,
Kanagawa, JP

Parameter/Equipment Range CMC2, 4, 8 (±) Comments 7637 Pulse Generator3 – Pulse 1, Pulse 2a, 2b, Pulse 3a, 3b, Pulse 5a, 5b: Vo lt a ge Rise Time Duration (0.1 to 660) V 1 ns to 5 µs 100 ns

UL LLC/UNDERWRITERS LABORATORIES TAIWAN CO.,
Zhudong Township, Hsinchu County, TW

ISO 16750-2; ISO 16750-2 (2010, 2012) Conducted Transient Immunity ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 7637-3; ISO 7637-3 (2016); SAE J1113-11; SAE J1113-12 Conducted Transient Emissions ISO 7637-2; ISO 7637-2 (2

Denken Co., Ltd. EMC Test Lab.
Kariya-shi, Aichi-ken,, JP

ISO 16750-2; ISO 16750-2:2012, Sections 4.6.3 and 4.6.4 Immunity to Magnetic Fields (10Hz to 150kHz) ISO 11452-8; ISO 11452-8:2015, Section 7.4 Portable Transmitters Immunity ISO 11452-9; ISO 11452-9:2012 IC Conducted Emissio

ZF Automotive UK
West Midlands, GB

ISO 16750-2:2012 1.1.7 Exported Spikes and Transients ISO 7637-2:1990 ISO 7637-2:2004 BOEING D6-16050-4:1991 BOEING D6-16050-5B:2004 BOEING D6-16050-5C:2006 DEF STAN 59-41: Issue 3:1988 DEF STAN 5

DEKRA IST Reliability Services
Hsinchu, TW

ISO 16750-2; GMW3172; VW 80000; GS 95024-2-1 1When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one y

LGAI TECHNOLOGICAL CENTER
Bellaterra, ES

ISO 16750-2; ISO 16750-2 (2006; 2012) Method of Testing for Immunity of Vehicles to Electromagnetic Radiation ISO 11451-2; ISO 11451-2 (2005); ISO 11451-3; ISO 11451-3 (2007; 2015) Over/Under, Reverse, Jump Start, Defective Regula

Hangzhou TDT Technologies Co.,
Hangzhou, Zhejiang, CN

ISO 16750-2 Magnetic Field Immunity Testing GB/T 33014.8; ISO 11452-8

SGS Germany
Puchheim, DE

ISO 16750-2:2023 Road vehicles — Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads 1.9 Kraftfahrzeuge (Automotive) Hersteller (Manufacturer) EMV LV124:2013 Elektrische und elektro

TÜV SÜD Product Service GmbH PS-SL-EMC / PS-SL-ENV-STR
Straubing, DE

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV ISO 11452 -2:2004 Road vehicles - Component test methods for electrical disturbances from narrowband radiat

Showing labs 150 of 80. Use pagination below to see more.