ISO 16750-2 Accredited Testing Labs Worldwide
217 accredited laboratories in 13 countries hold ISO 16750-2 in their accredited scope. We don't know yet whether 110 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body.
Available in 13 Countries
Sample labs
ISO 16750-2 (Sections 4.6.3 and 4.6.4 only) Vehicle and Machinery Standards ISO 13766-1; EN ISO 13766-1; ISO 13766-2; ISO 14982; EN ISO 13766-2 (except ISO 11452-5, ISO 12100, ISO 12630, ISO 13849, and ISO 15998); EN 14982 (exc
ISO 16750-2 ISO 16750-2: 2023 ISO 16750-2: 2012 ISO 16750-2: 2010 Road vehicles -- Environmental conditions and testing for electrical and electronic equipment -- Part 2: Electrical loads [excluding 4.11 & 4.12]
ISO 16750-2:2012; ISO 16750-2 (2023); Ford ES-XW7T-1A278-AA
ISO 16750-2 Apartados correspondientes a la versión del 2012 o apartados equivalentes en versiones posteriores. Section corresponding to 2012 version or equivalent sections in later versions A, B, D Código Validación Electrónica: 0Q
ISO 16750-2: 2012-11 Fourth edition Road vehicles – Environmental conditions and testing for electrical and electronic equipment – PART 2 loads EMV UN ECE R10 REV. 6 + Amendment 1 30.10.2020 R 10 Uniform provisions concerning t
ISO 16750-2 Absorber Lined Shielded Enclosure (ALSE) RF Immunity (80 MHz to 18 GHz) 80 to 200 MHz: 100V/m, 200 MHz to 4 GHz: 150V/m, 4 to18 GHz: 100V/m ISO 11452-2
ISO 16750-2 Oscilloscope, voltage probe, digital multimeter Automotive-Transient Pulse Simulators Road Vehicles – Electrical Disturbanes Conduction & Coupling Voltage Rise Time Duration Up to 600
ISO 16750-2:2023 Tecnica di prova O&I _ Denominazione della prova / Campi di prova Metodo di prova Tecnica di prova O&I Emissioni elettromagnetiche irradiate/Radiated emission Prove di immunità ai campi elettromagnetici irradiati/R
ISO 16750-2 Absorber Lined Shielded Enclosure (ALSE) RF Immunity (80 MHz to 6 GHz) Up to 200 V/m (Metallic Bench Only) Up to 600 V/m (Radar Pulse Only) ISO 11452-2; E/ECE/324/Add. 9 R10 (section 6.8) TEM Cell RF Immuni
ISO 16750-2: 2023-07 Road vehicles — Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads Without Ch. 4.13 (EMV) Elektrische Prüfungen IEC 60512-2-1: 2002-02 Connectors for elect
ISO 16750-2 Tri-Plate Line Method SAE J1113-25 Product Family Standard for Aftermarket Electronic Equipment in Vehicles EN 50498 Radio Tests (up to 40 GHz) (excluding DFS testing as applicable) US/FCC CFR 47, FCC Part 15C
ISO 16750-2 Immunity to Magnetic Fields ISO 11452-8 Stripline ISO 11452-5 Immunity to Portable Transmitters ISO 11452-9
ISO 16750-2 2023/07 Road vehicles – Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads Nicht 4.9 "Withstand voltage"; Nicht 4.10 "Insulation resistance" EMV ISO 21498-1 2021/
ISO 16750-2; GB/T 28046.2; VW VW80000; BMW GS-95003-2; BMW GS-95024-2-1; Daimler MBN LV 124-1; Ford EMC-CS-2009.1; FMC1278; GM GMW3172; Jaguar JLR-EMC-CS; Nissan 28401NDS02; Dong Feng EQC-1204; Dong Feng Q/EQCS-1204; GAC QJ/GAC 15
ISO 16750-2 2012-11 [Flex A] Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads 4.11 Withstand voltage 4.12 Insulation resistance Elektrotechnik ISO 16750-2 202
ISO 16750-2; ISO 21498-2; GB/T 28046.2; VW 80300; VW 80303 Current Harmonics GB 17625.1; IEC 61000-3-12; IEC 61000-3-2
Parameter/Equipment5 Range CMC2, 12, 13,14 (±) Comments6 Time Interval & Frequency3 (cont) – Voltage Transient Emission3 Switching Time Transient Immunity3 Surge Pulse & Load Dump Pulse Rise Time Dur
ISO 16750-2 2012-11 Ed. 4.0 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical Loads ISO 7637-2 2011-03 Ed. 2.0 Straßenfahrzeuge - Elektrische, leitungsgeführte und
ISO 16750-2 Road Vehicles – Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical loads (excluding Clause 4.13 Electromagnetic Compatibility) Battery Testing DOE/ID-11069 Ineel Battery Test Man
ISO 16750-2 Sections: 4.2 DC supply voltage 4.3 Overvoltage 4.7 Reversed voltage 4.10 Short circuit/ overload protection Free Fall ISO 16750-3 (Section 4.3)
ISO 16750-2:2023 Road vehicles -- Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads Abbreviations used: CISPR Comité international spécial des perturbation s r
ISO 16750-2; GB/T 21437.3; GB/T 28046.2; SAE J1113-12 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a per
ISO 16750-2 (2012); Hyundai/Kia ES 96200-00; ECE R10.07 Stripline Test (Immunity) ISO 11452-5 1When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediate
ISO 16750-2; GB/T 28046.2
ISO 16750-2, UL1449, GR1089 Tektronix TDS5104 w/high voltage deferential probe & current probe Flicker & Harmonics – Measure Voltage Fluctuations (Flicker) Mains Harmonic Emissions 230V, 50 Hz
ISO 16750-2:2012 Road Vehicles – Environmental conditions and testing for electrical and electronic equipment Part 2: Electrical loads EMV ISO 16750-2:2023 Road Vehicles – Environmental conditions and testing for electrical and electr
EMV ISO 7637 -2:2011 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMV ISO 7637 -3:2016 Road vehicles - Electrical disturbances from c
ISO 16750-2 / Electrical loads Load dump (Pulse 5b) Oscilloscope, Transient generator, Voltage probe, Resistor Time (s) Voltage (V)
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren / Standort EMV Volvo STD 515 -0003 Version 2 2006/05 Volvo Group PARTS AND COMPONENTS Electro-ma
ISO 16750-2 Emissions Harmonics and Flicker EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; SANS 61000-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; SANS 61000-3-3 Conducted (excluding Broadcast Receivers)
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV DIN EN 62920:2018 -07 Photovoltaische Stromerzeugungssysteme - EMV- Anforderungen und Prüfverfahren für Leist
ISO 16750-2: 2012 ISO 16750-2: 2023 Road vehicles -- Environmental conditions and testing for electrical and electronic equipment -- Part 2: Electrical loads EMV ANSI C63.4:2014 American National Standard for Methods of Measureme
ISO 16750-2 (excluding ISO 11451, ISO 11452-3/5/10 and CISPR 12)
ISO 16750-2; GMW 3172 Sections 8.2 & 9.2 Radiated & Conducted Emissions (Unintentional) 47 CFR FCC Part 15, Subpart B (using ANSI C63.4-2014); ICES-003 Radio (Unlicensed Intentional Radiators) 47 CFR, FCC Part 15, Subpa
ISO 16750-2 Tri-Plate Line Method SAE J1113-25 Emissions Radiated ANSI C63.4 (up to 18 GHz) Conducted ANSI C63.4 (150 kHz to 30 MHz); CISPR 16-2-1 (Measurements with AMN only, continuous disturbances only) Harmonics UN
ISO 16750-2 (2023); ISO 16750-2 (2010, 2012); ISO 16750-2; SAE J1113-13 Automotive Electrical Tests of the following types: Test(s): Test Method(s) 1: - Jump Start - Reverse Polarity - Over Voltage - State Change Waveform Ch
ISO 16750-2 II. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 4, 6 (±) Comments RF Power3 – Measure 9kHz to 7 GHz (-70 to +20) dBm 0.3 dB Spectrum Anal
ISO 16750-2 (2010, 2012) * Also using customer-specified methods related to the types of tests listed above.
ISO 16750-2; SAE J1113-11; SAE J1113-12 RTCA/DO-160 D, E, F, G Magnetic Effects Section 15 Power Input Section 16 Voltage Spike Section 17 Audio Frequency Conducted Susceptibility - Power Inputs Section 18 Induced Signa
Prüfungen in den Bereichen: ausgewählte elektrische Messungen Innerhalb der mit * gekennzeichneten Akkreditierungsbereiche ist dem Prüflaboratorium, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die Anwendu
ISO 16750-2; UNECE Regulation 10, Revision 6, Electronic Sub-assemblies (ESA), Sections 6.7, 6.9, 7.17, 7.19 Wireless (Excluding HAC & SAR) ANSI/TIA 603-E; EN 300 113; EN 300 220-1; EN 300 220-2;
Parameter/Equipment Range CMC2 (±) Comments RF Speed Guns – Speed (5 to 1000) m/s 0.09 m/s Agilent 33210A, HP 53152A, NSI-MI Technologies MI-210-26A Surge Generators3 – Voltage
ISO 16750-2:2012-11 Edition 4 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads Keine Prüfungen nach Abschnitt 4.6.4
ISO 16750-2:2012 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen für elektrische und elektronische Ausrüstungen - Teil 2: Elektrische Beanspruchungen Road vehicles - Environmental conditions and testing for electrical and elect
Fachbereich Norm oder Hausverfahren / Ausgabestand Titel der Norm oder des Hausverfahrens Einschränkungen zum Prüfverfahren Automotive Components ISO 8820 -5:2015 Road vehicles - Fuse -links - Part 5: Fuse-links with axial term
ISO 16750-2) Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Vedere elenco dei dettagli delle prove flessibili/See
ISO 16750-2:2012 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads ISO 16750-3:2012-12 Straßenfahrzeuge - Umgebungsbedingungen und Prüfungen von elektrischer und e
ISO 16750-2; IEC 61851-21-2; UN ECE REG 10 (Automotive) Earth-moving and building construction machinery – Machines with internal electrical power supply ISO 13766-1; ISO 13766-2 Unintentional Emissions Radiated & Conducted U
ISO 16750-2
ISO 16750-2; GMW3172; VW 80000; VFDST00028121; TSC0506G; Q/HHT-TS002; FMC 1278; EMC_CS_2009; CS.00054; GS 95024-2; RDNS-00517; JLR-EMC-CS v1.0; B21 7110; MES PW 67602C; MES PW 67602D; TS-0000425-05; QJXP 07JT.023 Electrical fast
Showing labs 1–50 of 217. Use pagination below to see more.