Alamance Foods
Burlington, NC, US
American Association for Laboratory Accreditation (A2LA) is an accreditation body in the United States. It is one of several such bodies there, so an American lab may hold its accreditation from a different one. This directory lists 3,537 laboratories holding active ISO/IEC 17025 accreditation from A2LA in 64 countries, 2,549 of them in the United States. Official site: www.a2la.org.
Each type-of-testing page lists the labs of every accreditation body.
Burlington, NC, US
Anchorage, AK, US
FDA WEAC (SOP-Chemistry-034) Inorganic Arsenic Analysis HPLC-ICP/MS EAM 4.10, 4.11 (modified) (SOP- Chemistry-036) Methylmercury HPLC-ICP/MS FDA 4.8 Total Metals Analysis Microwave Digestion EAM 4.7
Lapeer, MI, US
ASTM D3359; Ford FLTM BI 106-01; GMW 14829; ISO 2409; VCS 1029, 54729 Chip Resistance GMW 14700, except method A; SAE J400; LP.7M014 Color Evaluation Ford FLTM BI 109-1; SAE J1545, SAE J361 Cure Check GMW 15891 Film Build ISO
Beltsville, MD, US
SSD:TM:513 LC/MS/MS Determination of Cannabinoids in Beverage Alcohol Products using LC/MS/MS (Δ9-THC, Δ8-THC, THCA, CBD, CBDA, CBN) SSD:TM:317 Spectroscopy Determination of Sodium and Potassium with Flame AA SSD:TM:510 Wet Chemi
Dallas, TX, US
ANSI B1.2-1983 & ASME/ANSI B1.3- 2007 Taper Thread Rings – Pitch Diameter Up to 3 in 120 µin Setting plug, standoff to master Thread Wires (4 to 80) TPI (11 + 1.5L) µin Master thread wire set
Saint Jacob, IL, US
ASTM E77, ASTM E2623 Ovens/Furnaces/Chamber – System Accuracy 3 (-115 to 120) °F (70 to 1000) °F 1.3 °F 1.5 °F Data loggers w/ probe Infrared Thermometers3 (82 to 752) °F 2.8 °F Blackbody IR thermometer cali
Morristown, TN, US
ASTM Class 1 mass Crimpers3 – Pull Force Jaw Force Up to 500 lbf Up to 15 Tons 6.4 % 2.8 % Force gauge Load cell Pressure Gauge3 Absolute Up to 1 in H2O (1 t
Milwaukie, OR, US
NIST.IR.5672 and NIST.IR.6969
Wayland, MI, US
Sandwich, MA, US
Shreveport, LA, US
Spartanburg, SC, US
Garden Grove, CA, US
European Pharmacopoeia, Ph.Eur. British Herbal Pharmacopoeia, BHP American Herbal Pharmacopoeia, AHP United States Pharmacopeia, USP Pharmacopoeia of the People’s Republic of China, PPRC Official Methods of Analysis of AOAC Internati
Paris, OH, US
ACP-041; direct reflective pickup tachometer (LSD = least significant digit) Time Interval – Timers & Stopwatches3 15 s to 24 hr 0.36 s 24 hr test Method: ACP-048; NIST synchronized time Frequency Generate – Measu
Houston, TX, US
ASTM C42/C42M Obtaining and Testing Drilled Cores and Sawed Beams of Concrete ASTM C138/C138M1 Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete ASTM C143/C143M1 Slump of Hydraulic-Cement Concrete ASTM C172/C17
Houston, TX, US
ASTM C31/C31M* Making and Curing Concrete Test Specimens in the Field ASTM C39/C39M Compressive Strength of Cylindrical Concrete Specimens ASTM C42/C42M* Obtaining and Testing Drilled Cores and Sawed Beams of Concrete ASTM C138/C138M*
Webster, TX, US
ISO 14644-3 B.2 IEST-RP-CC006.3 Differential/Static Pressure3 Cleanroom BSC/LAFW CAI CACI QWI-CE02 QWI-CE07 QWI-CE05 QWI-CE01 CAG-003 IEST-RP-CC002.4 CAG-002 CAG-002 Particle Concentration3 Cleanroom, Primary Engineering
Arlington, TX, US
MIL-STD-120 (Canceled 1996) Threads Pitch Diameter Functional Diameter Radius (Up to 2) in #0 to 1 ¾ in (80 to 8 threads) per inch #4 to 1.0 in (40 to 8 threads) per inch
Houston, TX, US
ASTM D558 Moisture-Density (Unit Weight) Relations of Soil-Cement Mixtures ASTM D698 Laboratory Compaction Characteristics of Soil Using Standard Effort ASTM D854 Specific Gravity of Soil Solids by Water Pycnometer ASTM D1140 Amount o
Wichita, KS, US
ISO 6789:2003 manually applied and measured with a transducer Hydraulic pressure measured and compared to torque measured by transducers Pneumatic pressure set and torque measured with transducer Digi
Dallas, TX, US
USP <61,2021> (QCM.002) Bile Tolerant Gram Negative Bacteria USP <62> (QCM.013) Burkholderia cepacia Complex USP <60> (QCM.013) Candida albicans USP <62> (QCM.013) Coliform Count AOAC 991.14 (QCM.002) Enterobacteriaceae Cou
Altoona, PA, US
Hudson, OH, US
ASTM D1646, D2084, D5289, D6204, D6601 with temperature probe & meter ITS 90, oil bath with SPRT & digital readout V. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Dwell Time Up t
Livonia, MI, US
MIL-STD-120 (Canceled 1996)3 CMM machine / MIL-STD-120 (Canceled 1996)3 Linear 1D 2D 3D (0.028 to 1.00) in Up to 1.0000 in Up to 3.0000 in Up to 1.000 in Up to 6.000 in Up to 1.00
Fort Worth, TX, US
ASTM D1414 Section 8 & 9 ASTM D1414 Section 10 & 11 ASTM D1414 Section 16 Rubber: Tensile Up to 6 750 lbf ASTM D412 ISO 37 Tear Up to 6 750 lbf ASTM D624; ISO 34-1 Compression Up to 6 750 lbf ASTM D575 ISO 7743 Compressi
Aurora , NE, US
AOAC 990.12 ID #49163 Coliform Count (PetrifilmTM) AOAC 991.14 ID #49266 Enterobacteriaceae Count (PetrifilmTM) AOAC 2003.01 ID #49264 Escherichia coli Count (PetrifilmTM) AOAC 991.14 ID #49266 Salmonella BAX AOAC 2003.
Leipsic, OH, US
Marshfield, WI, US
AOAC 2014.05 ID #51397 Salmonella Analysis (BAX) AOAC 2013.02 ID #58038 Salmonella Confirmation FDA BAM Ch. 5 Sections E. and F.9.c. Online Edition (modified) ID #12869 Salmonella spp. Analysis (Solus) AOAC PTM 051601 ID #5
Willmar, MN, US
AOAC 2013.01 ID #14179 Salmonella Analysis (BAX Real-time PCR) AOAC 2013.02 ID #84776 Shigella spp. Analysis FDA BAM Chapter 6 Shigella (modified) ID #11711 Staphylococcus aureus (Staph Express) Plate Count (Petrifilm™)
Torrance, CA, US
Valley View, OH, US
ASTM D664 (Modified); ALS SOP 6003 Acid Number by Colorimetric Titration ASTM D974 Base Number by Potentiometric Titration ASTM D4739 (Modified); ALS SOP 6004 Wear, Additive and Contaminant Metals by ICP/OES Ag, Al, B, Ba, Ca, Cr,
Phoenix, AZ, US
ASTM D664 (Modified); ALS SOP 6003 Base Number by Potentiometric Titration ASTM D4739 (Modified); ALS SOP 6004 FTIR (general setup and use) Oxidation Sulphation Nitration Soot ASTM D7418, E2412 ASTM D7414, E2412 ASTM D7415,
Kansas City, KS, US
ASTM D7593 Particle Count by Light Extinction ASTM D7647 Particle Count Coding ISO 4406 Viscosity, Kinematic (CAV) ASTM D445; (Modified); ALS NAM-KAN-AP-5047 Water by Karl Fischer, Coulometric Titration ASTM D6304B Wear, A
Norcross, GA, US
ASTM D664 (Modified); ALS SOP 6003 Acid Number by Colorimetric Titration ASTM D974 Base Number by Potentiometric Titration ASTM D4739 (Modified); ALS SOP 6004 FTIR (general setup and use) Oxidation Sulphation Nitration Soot
Portland, OR, US
ASTM D664 (Modified); ALS SOP 6003 Base Number by Potentiometric Titration ASTM D4739 (Modified); ALS SOP 6004 Fuel Dilution by Gas Chromatography ASTM D7593 FTIR (general setup and use) Oxidation Sulphation Nitration Soot ASTM
Kansas City, KS, US
ASTM D664 (Modified); ALS SOP 6003 Antioxidant Content by Linear Sweet Voltammetry Hindered Phenolic and Aromatic Amines ASTM D6971 Base Number by Potentiometric Titration ASTM D4739 (Modified); ALS SOP 6004 Flash Point by Pensky
Seymour, IN, US
ASTM D792 (Method B) ISO 1183-1 Melt Flow Rate ASTM D1238 (Procedure A) Tensile ASTM D638 Elongation ASTM D638 Flexural ASTM D790 Ash ASTM D5630 (Procedure B) Izod Impact ASTM D256; ISO 180 Moisture ASTM D6980 Mooney Viscosity AS
Ponce, US
EPA 180.1 EPA 180.1 ----------------------- Metals Inorganics Aluminum EPA 200.8 EPA 200.8 ----------------------- Antimony EPA 200.8 ----------------------- SW 846-6020 B Arsenic EPA 200.8 EPA 200.8 SW 846-6020 B Barium EPA 200.8 EPA
Richmond, VA, US
ASTM E2187-04; E2187-09 095-3391 Determination of pH by the Center for Disease Control Method FR Vol. 74, No. 4 pp. 712-719 ISO 21109 095-3370 Determination of pH in OTDN Products and E- Liquid Formulations FR Vol. 74, No. 4 pp. 712-71
Hudson, OH, US
Twin Falls, ID, US
ICUMSA Method GS2/3/9-17 Determination of Granulation in White Sugar MOA-5 ICUMSA GS2/9-37 (Modified) Determination of Sulfite by the Rosaniline Colorimetric Method in Sugar MOA-3 ICUMSA GS2-33 (Modified) Determination of Turbi
Phoenix, AZ, US
ASTM D1119 Boiling Point ASTM D1120 Reserve Alkalinity ASTM D1121 Density ASTM D5931 % Water by Karl Fisher Method ASTM D1123 (Method A) Freezing Point by Dry Ice (°F) ASTM D1177 pH of Coolant ASTM D1287 Corrosion Test ASTM D1384 E
Winston-Salem, NC, US
ASTM E330 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference ANSI/DASMA 108 1 When the date, edition, version, etc. is not identifi
North Reading, MA, US
IEC 61000-4-2; AS/NZS 61000.4.2 EN/IEC 61000-4-3; AS/NZS 61000.4.3 Conducted Immunity (0 Hz to 150 kHz) Electrical Fast Transient / Burst Immunity EN/IEC 61000-4-16; AS/NZS 61000.4.16 EN/IEC 61000-4-4; AS/NZS 61000.4.4 Sur
Danvers , MA, US
Rochester Hills, MI, US
ASTM D395 (Method B) Dry Film Thickness ASTM B499, D7091 Hardness Brinell (500kg/10mm, 3000kg/10mm, 5kg/1mm, 30kg/1mm) ASTM E10 Durometer (Shore A) ASTM D2240 File Hardness SAE J864 International Hardness (IRHD) ASTM D1415 Ro
St. Marys, PA, US
ASTM E8/E8M; MPIF 10 Hardness (Rockwell A, B, C, F, 15T, 15N) ASTM E18; MPIF 43 Microhardness (Knoop & Vickers, (100, 200) g) ASTM B933, B934, E384; MPIF 51, MPIF 52 Metallography Microstructure Microetching Carbon Con
Green Bay, WI, US
Maumee, OH, US
Albuquerque, NM, US
ASTM C473 Flexural Strength (Method B, Para. 11) Core, End, and Edge Hardness (Method B, Para. 12) Nail Pull Resistance (Method B, Para. 13) End Squareness (Para. 15) Thickness (Para. 16) Recessed or Tapered-Edge Depth (Para. 17)
Showing labs 101–150 of 3,537.
Each lab page shows which of its certificates are active.
Search covers every A2LA lab we hold, filtered to this body, and narrows further by country, city or a term from the scope text itself.
Search A2LA accredited labs