FindTestingLabs
Registers collected 2026-08-22.See collection dates

IEC 61000-4-6 Accredited Testing Labs Worldwide

176 accredited laboratories in 13 countries hold IEC 61000-4-6 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body. In the register, IEC 61000-4-6 scope entries most often cover Impedance, Frequency, Harmonics in Air, Electronic, Medical equipment, electrical safety and EMC.

Total labs
176
Countries
13

Available in 13 Countries

China
49 labs
Germany
48 labs
United States
32 labs
Japan
13 labs
United Kingdom
10 labs
Italy
8 labs
Taiwan
6 labs
India
3 labs
Finland
3 labs
South Korea
2 labs
Netherlands
2 labs
Canada
2 labs
France
1 lab

Top matrices for IEC 61000-4-6

Top analytes for IEC 61000-4-6

  • Impedance (5)
  • Frequency (2)
  • Harmonics (2)
  • Insertion Loss (2)
  • Emissions (Radiated And Conducted) (1)
  • Coupling Factor (1)
  • Emissions (1)
  • Harmonic Current Emissions (1)

Sample labs

UL Japan
Ise-shi, Mie, JP

IEC 61000-4-6; EN 61000-4-6; SANS 61000-4-6 Magnetic Field Immunity (excluding short duration mode) IEC 61000-4-8; EN-61000-4-8; SANS 61000-4-8 Dips, Short Interrupts, & Voltage Variations IEC 61000-4-11; EN 61000-4-11; EN IEC

Eurofins Electrical & Electronic UK
Eastleigh, GB

IEC 61000-4-6:2013 up to 10 Vrms EN IEC 61000-4-6:2023 1.6 Radiated RF Immunity EN 61000-4-3:2006 A 26 MHz to 1 GHz @ 20V/m + A1:2008 + A2:2010 1 GHz to 6 GHz @ 10V/m IEC 61000-4-3:2006 + A1:

TUV SUD Limited (Trading as TUV SUD)
Hampshire, GB

IEC 61000-4-6:2003 including Amendment 1:2004 and Amendment 2:2006 A, B IEC 61000-4-6 ed 3:2008 A, B EN 61000-4-16:1998 Clause 6.1.3 A, B IEC 61000-4-6:ed 2.1:2004 A, B IEC 61000-4-6:ed 2.2:2006 A, B ECE Regulation 10.03:20

Element Materials Technology - Malvern
Malvern, GB

IEC 61000-4-6:2013; EN/IEC 61000-4-6 EMC – Commercial Immunity: Power Frequency Magnetic Field EN/IEC 61000-4-8:2009; EN/IEC 61000-4-8 EMC – Commercial Immunity: Pulse Magnetic Fields EN/IEC 61000-4-9:2016; EN/IEC 61000-4-9 EMC

LabSure Testing Services (Tianjin) Co.,Ltd.
Tianjin, CN

IEC 61000-4-6:2023; EN IEC 61000-4-6:2023; IEC 61000-4-6 Ed. 5.0 (2023-06); BS EN 61000-4-6 (2014); IEC 61000-4-6 Ed. 3.0 (2008); IEC 61000-4-6 Ed. 4.0 (2013); EN 61000-4-6 (2009) Power Frequency Magnetic Field (Up to 30 A/m) BS

E & C Testlab GmbH (Engineering & Certification Testlab GmbH)
Trossingen, DE

IEC 61000-4-6:2013); Deutsche Fassung EN 61000-4-6:2014 ohne Tabelle G.5 Tabelle G.6

The EMC Shop
Rocklin, CA, US

IEC 61000-4-6 Network Analyzer ESD Current Targets – Resistance Insertion Loss Transfer Impedance <100 Ω 100 kHz to 4 GHz 1 A 0.06 Ω 0.65 dB 2.0 % IEC 61000-4-2 Network analyzer, digita

Bureau Veritas Consumer Products Services (Hong Kong) Ltd., Taoyuan Branch
Taoyuan City, TW

IEC 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field Immunity IEC/EN 61000-4-8; BS EN 61000-4-8 Pulse Magnetic Field IEC/EN 61000-4-9; BS EN 61000-4-9 Voltage Dips, Short Interruptions, and Line Voltage Variation

UL International Germany
Neu-Isenburg, DE

IEC 61000-4-6: 2023 EMC – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields EMV EN 61000-4-8: 2010 EMC – Part 4-8: Testing and measurement techniques – Power freq

TUV ITALIA
Volpiano, IT

TUV ITALIA SrL Via Brandizzo 123 10088 Volpiano TO Allegato al certificato di accreditamento n. 00077 rev. 7 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 10 Sede B Data: 19/03/2025 pag. 8 di 62 Prova di immunità a on

EMC Testhaus GmbH & Co. KG
Siegen, DE

IEC 61000-4-6:2013); Deutsche Fassung EN 61000-4-6:2014 EMV IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency field

TUV SUD Certification and Testing (China) Co.,
Wuxi, CN

IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8

TUV SUD Japan Ltd. Yonezawa Testing Center (EMC Lab)
Yamagata, JP

IEC 61000-4-6; KS C 9610-4-6; JIS C 61000-4-6; EN IEC 61000-4-6; IEC 61000-4-6:2013; EN 61000-4-6:2014 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; JIS C 61000-4-8 Pulse Magnetic Field Im

HCT Co.,
Icheon-Si, Gyeonggi-Do, KR

IEC 61000-4-6; IEC 61000-4-6:2013 Power Frequency Magnetic Field Immunity IEC 61000-4-8 Power Quality Failure – Voltage, Dips, and Interruptions IEC 61000-4-11; IEC 61000-4-11:2004+AMD1:2017 Radiated Fields in Close Proximity

TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch
China, DE

IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8 Voltage Dips, Interruptions, and Line Voltage Variations IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11 Radiated Field in close

SGS Taiwan
Taoyuan, TW

IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6 Magnetic Fields Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dip and Interrupt IEC 61000-4-11; EN 61000-4-11;

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch
Dongguan City, Guangdong Province, CN

IEC 61000-4-6; EN 61000-4-6; GB/T 17626.6; AS/NZS 61000.4.6; CNS 14676-6; BS EN 61000-4-6; SANS 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6 Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; GB/T 17626.8; AS/NZS 61000.4.8; C

Element Materials Technology Denver-Longmont
Longmont, CO, US

IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6 Magnetic Field Immunity IEC 61000-4-8 (excluding short duration mode); EN 61000-4-8 (excluding short duration mode); KS C 9610-4-8 (excluding short duration mode);

QIMA Testing (Germany)
Hamburg, DE

IEC 61000-4-6:2013) EMV IEC 61000 -4-6 ed. 4.0: 2013 Electromagnetic compatibility (EMC) - Part 4 - 6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EMV IEC 61000 -

Shenzhen BANTEK Testing Co.,
ShenZhen, CN

IEC 61000-4-6; EN 61000-4-6

Sporton International Inc. (Kunshan)
Jiangsu Province, CN

IEC 61000-4-6; BS EN/EN 61000-4-6; AS/NZS 61000.4.6; SANS 61000-4-6 Magnetic Immunity IEC 61000-4-8; BS EN/EN 61000-4-8; AS/NZS 61000.4.8; SANS 61000-4-8 Voltage Dips and Interrupts IEC 61000-4-11; BS EN/EN 61000-4-11; AS/NZS 61000.

STC Germany
Frontenhausen, DE

IEC 61000-4-6:2023 Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio- frequency fields EM V BS EN 61000-4-6:2014 (EN 61000-4-6:2014) Electrom

SGS Japan
Yokohama, JP

IEC 61000-4-6 1; EN 61000-4-6 1; KS C 9610-4-6 1 Transients and Surges in the Vehicular Environment ISO 7637-2 Magnetic Field Immunity IEC 61000-4-8 1; EN 61000-4-8 1; KS C 9610-4-8 1 Voltage Dips, Short Interruptions a

BEC Incorporated
Pottstown, PA, US

IEC 61000-4-6 Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8 Voltage Dips, Short Interruptions, and Voltage Variations EN 61000-4-11; IEC 61000-4-11 Product Family/Generic Standards and Industry Standards EN 61000-6-1; EN

UL Japan, Inc. - Kashima EMC
Chiba-ken, 289-0341, JP

IEC 61000-4-6 Standard equipment: network analyzer, calibration kit Parameter/Range Frequency CMC2, 5, 6 (±) Comments4 Directional Coupler3 – Insertion Loss, Coupling Factor, & Isolation – (0 to 50) dB

PRO EMV Labor Strausberg
Strausberg, DE

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren 1 Grundnormen EMV DIN EN 61000-4-2:2009 Elektromagnetische Verträglichkeit (EMV) – Teil 4-2: Prüf- und Mes

Intek S.p.a.
Rezzato, IT

IEC 61000-4-6:2023, IEC 61000-4-6:2023 Prove di immunità ai transitori - raffiche di impulsi elettrici veloci (burst)/Electrical fast transient - burst immunity test (4 kV) EN 61000-4-4:2012, IEC 61000-4-4:2012 Prove di immunità alle on

EST Technology Co.,
Dongguan, Guangdong, CN

IEC 61000-4-6; BS EN 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8 Voltage Dips and Short Interruptions EN 61000-4-11; IEC 61000-4-11; BS EN IEC 61000-4-11 Generic or Produc

Eleforss
Tampere, FI

IEC 61000-4-6:2023 EN 61000-4-6:2014 + AC:2015 EN 61000-4-6:2009 Tampere Sähköiset ja elektroniset laitteet Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests EN IEC 61000-4-11:2020

Core Compliance Testing Services
Hudson, NH, US

IEC 61000-4-6; AS/NZS 61000-4-6; AS IEC 61000-4-6; KS C 9610-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-8; KS C 9610-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variation

Audix Technology (Wujiang)
China, DE

IEC 61000-4-6:2023 EN61000-4-6:2014 EN61000-4-6:2014+AC:2015 EN IEC 61000-4-6:2023 BS EN IEC 61000-4-6:2023 BS EN 61000-4-6:2014 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conduc

Shenzhen CTA Testing Technology Co.,
Shenzhen, CN

IEC 61000-4-6; EN 61000-4-6 Vo lt a ge Dips, Short Interrupts, and V oltage Variations IEC 61000-4-11; EN 61000-4-11

IMST GmbH Prüfzentrum / Testcenter
Kamp-Lintfort, DE

IEC 61000-4-6:2013); Deutsche Fassung EN 61000-4-6:2014 EMV DIN EN 61000 -4-8: 2010-11; VDE 0847-4-8: 2010-11 Elektromagnetische Verträglichkeit (EMV) - Teil 4-8: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen Magne

Nebraska Center for Excellence in Electronics
Lincoln, NE, US

IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; AS/NZS 61000.4.6; SANS 61000-4-6; ISO 11452-4 Power Line Magnetic Field IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; AS/NZS 61000.4.8; SANS 61000-4-8 Voltage Dips and Fluctuations IEC 61000

Industrieanlagen- Betriebsgesellschaft mit beschränkter Haftung Prüflabor für Qualifikationstests des Raumfahrt-Testzentrums
Ottobrunn, DE

IEC 61000-4-6:2013 Electromagnetic compatibility (EM C) - Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6:2013); German Version EN 61000-4-6:2014 Witho

Fischer Custom Communications
Torrance, CA, US

IEC 61000-4-6 Ed. 5 EM Injection Clamp – Insertion Loss (dB) “K” Factor/Coupling Factor (dB) Impedance (Ω) Decoupling Factor (dB) 10 kHz to 1 GHz 10 kHz to 1 GHz 100 kHz to 100 MHz 100 kHz to 100 MHz

SLG-CPC TEST LABORATORY CO.,
Dongguan, Guangdong Province, CN

Test(s) Test Method(s) 1: Japan (continued) J55014-1(Except Section 4.2 Discontinuous disturbances test); J55015; J55032 Harmonics IEC/EN 61000-3-2; BS EN 61000-3-2; AS/NZS 61000.3.2 Flicker IEC/EN 61000-3-3; BS EN 61000-3-3; AS/N

TOYO Corporation Calibration Laboratory
Tokyo 103-8284, JP

IEC61000-4-6 Power Meter/Sensor3, 8 – Calibration Factor Linearity VSWR 9 kHz to 6 GHz 10 MHz to 18 GHz 50 MHz to 26.5 GHz (26.5 to 40) GHz 9 kHz to 6 GHz 10 MHz to 18 GHz 50 MHz to 40 GHz 9 k

JianYan Testing Group Shenzhen Co.,
Shenzhen, Guangdong, CN

IEC 61000-4-6; BS EN 61000-4-6 Voltage Dips, Short Interruptions, and Voltage Variations EN 61000-4-11; EN IEC 61000-4-11; IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11 Magnetic Field EN 61000-4-8; IEC 61000-4-8; BS E

TÜV Technische Überwachung Hessen GmbH EMV-Labor
Kassel, DE

IEC 61000-4-6:2013)

Shenzhen Tiansu Calibration and Testing Co.,
Shenzhen, Guangdong, CN

IEC 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 V oltage Dips, Short Interruptions, and V oltage Variations IEC 61000-4-11; BS EN IEC 61000-4-11;

TÜV Rheinland LGA Products
Nürnberg, DE

IEC 61000-4-6 2013-10 Ed. 4.0 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 2010-02 Electromagnetic compatib

CTSL Testing (Dongguan) Co.,
Dongguan, CN

IEC 61000-4-6; IEC 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variations EN IEC 61000-4-11; IEC 61000-

Siemens Aktiengesellschaft Type Test Laboratory Electronics Siemens Motion Control
Erlangen, DE

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Grundnormen EMV IEC 61000 -4-2: 2008 Electromagnetic compatibility (EMC) – Part 4 - 2: Testing and

EMTEK (Shenzhen) Co.,
Shenzhen, US

IEC 61000-4-6; EN IEC 61000-4-6; IEC 61000-4-6

CE-LAB GmbH. EMV-Prüfzentrum
Ilmenau, DE

Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren/ Einschränkungen 1 Grundnormen EMV DIN EN 61000-4-2:2009-12 VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) -

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE

IEC 61000-4-6:2013); Deutsche Fassung EN 61000-4-6:2014

TUV SUD Canada
Gormley, ON, CA

IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6 Power Frequency Magnetic Field Immunity 3 IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8 Voltage Dips, Short Interruptions, and Line Voltage Variations 3 IEC 61000-4-11; EN 61000-4-11;

Advanced Test Equipment
San Diego, CA, US

IEC 61000-4-6, DO 160, CISPR 16-1-2, CISPR 22, CISPR 25, CISPR 32 Agilent VNA E5061B III. Thermodynamics Parameter/Equipment Range CMC2, 6 () Comments Temperature – Measure (-196 to 420) °C 0.59

CSA Group Bayern
Plattling, DE

IEC 61000-4-6:2008 Electromagnetic compatibilit y (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test EMV DIN EN 61000-4- 6:2014 VDE 0847-4-6:2014 (EN 61000-4-6:2014) Elektromagnetische Verträglichkeit (EMV) -

Showing labs 150 of 176. Use pagination below to see more.