IEC 61000-3-2 Accredited Testing Labs Worldwide
268 accredited laboratories in 18 countries hold IEC 61000-3-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body. In the register, IEC 61000-3-2 scope entries most often cover Harmonic Current Emissions, Voltage, Radiated Emissions in Air, Electronic, Medical equipment, electrical safety and EMC.
Available in 18 Countries
Top matrices for IEC 61000-3-2
Top analytes for IEC 61000-3-2
- Harmonic Current Emissions (9)
- Voltage (6)
- Radiated Emissions (5)
- Current Harmonics (5)
- Impedance (5)
- Emissions (4)
- Harmonics (4)
- Harmonic Current (3)
Sample labs
Test Technology: Test Method(s) 1: Immunity to changes in power frequency EN 61000-4-28; IEC 61000-4-28; GB/T 17626.28; BS EN 61000-4-28 Voltage dips, short interruptions and voltage variations immunity tests for equipment with
IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2 Flicker IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3 Generic and Product Family Standards 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014);
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Eurofins Electrical & Electronic UK Limited Issue No: 081 Issue date:
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK TUV SUD Limited (Trading as TÜV SÜD) Issue No:
Test Technology: Test Method(s) 1,2: EMC – Commercial Immunity: Surge EN/IEC 61000-4-5:2005; EN/IEC 61000-4-5 EMC – Commercial Immunity: Conducted Immunity EN/IEC 61000-4-6:2013; EN/IEC 61000-4-6 EMC – Commercial Immunity: Pow
Test(s): Test Method(s): Generic Emissions Standards (continued) EN IEC 61000-6-3:2021; IEC 61000-6-3 Ed. 3.0 (2020-07); BS EN 61000-6-3 (2007) + A1 (2011); EN 61000-6-3 (2007) + A1 (2011); AS/NZS 61000-6-3 (2007); BS EN 61000-6
Norm / Ausgabedatum Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) FGW TR2, R ev. 18 * 2022-12 Bestimmung von Leistungskurve und standardisierten Ene
Fach- bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung EMV IEC 61000-4-2: 2008 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electros
Parameter/Equipment Range CMC2, 3 (±) Comments CDNs (Coupling & De- Coupling Network) – Insertion Loss Impedance Phase 150 kHz to 400 MHz 150 kHz to 400 MHz 150 kHz to 400 MHz 0.11 dB 0.
Test Technology: Test Method(s) 1: Immunity Electrostatic Discharge (ESD) IEC/EN 61000-4-2; BS EN 61000-4-2; EN IEC 61000-4-2; BS EN IEC 61000-4-2 Radiated Immunity IEC/EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC
Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV ETSI EN 301 489-51 V2.1.1 (2019) ElectroMagnetic Co
TUV ITALIA SrL Via Brandizzo 123 10088 Volpiano TO Allegato al certificato di accreditamento n. 00077 rev. 7 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 10 Sede B Data: 19/03/2025 pag. 8 di 62 Prova di immunità a on
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens1 Prüfbereich / Einschränkung EMV DIN EN IEC 61000-3-11; VDE 0838-11:2021-03 Elektromagnetische Verträglichkeit (EMV) Teil 3-11: Grenzwerte - Begrenzung
IEC 61000-3-2; IEC 61000-3-12 Flicker IEC 61000-3-3; IEC 61000-3-11 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2 Radiated Immunity (20MHz- 6000MHz, 30V/m) IEC 61000-4-3; EN 61000-4-3 Electrical Fast Transient / B
Testing Activities Performed in Support of FCC Certification in Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.1 Rule Subpart/Technology Test Method Maximum Frequency (MHz) Unintentional Rad
IEC 61000-3-2; IEC 61000-3-2:2005+AMD1:2008+AMD2:2009 Power Line Flicker IEC 61000-3-3 Immunity Electrostatic Discharge IEC 61000-4-2; IEC 61000-4-2:2008 Radiated Immunity IEC 61000-4-3; IEC 61000-4-3:2006+AMD1:2007+AMD2:2010
Test Technology: Test Method(s)1: Conducted Immunity IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8 Voltage Dips, Interruptions, and Line Voltage Variat
IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2 Voltage Fluctuations and Flicker IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3
IEC 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; BS EN IEC 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; AS/NZS 61000.3.3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; AS/NZS
Test Technology: Test Method(s)1: Surge Immunity IEC/EN 61000-4-5; AS/NZS IEC 61000.4.5; GB/T 17626.5; BS EN 61000-4-5 Power Frequency Magnetic Field Immunity IEC/EN 61000-4-8; AS/NZS 61000.4.8; GB/T 17626.8; BS EN 61000-4-8
C.E.I.A. Spa a socio unico Sez. LACE Laboratorio di Compatibilità Elettromagnetica UNI CEI EN ISO/IEC 17025:2018 Strada Provinciale Pescaiola 52-52/A 52041 Civitella in Valdichiana AR Revisione: 13 Sede A Data: 20/11/2025 pag. 2
Test Technology: Test Method(s) 1, 2, 3: Generic / Product Family / Product Specific Standards (cont.) ISO 80601-2-56, clause 202; ISO 80601-2-61 (2017), clause 202; ISO 80601-2-61 (2011), clause 202; ISO 9919 Ed. 2.0 (2005), clau
Test Technology: Test Method(s) 2: Generic Standards, Product Family Standards, and Industry Specific Standards (cont.) SANS 61000-6-4; BS EN IE
(A2LA Cert No. 214.43) Revised 2/16/2026 Page 2 of 3 Test Technology Test Methods 1: Surge IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEEE C62.41.1 (2002); IEEE C62.41.2 (2002); IEEE C62.45 (2002) Conducted Immunity IEC 61000-4-6;
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV IEC 61000 -4-13 ed. 1.2: 2015 Electromagnetic compatibility (EMC) - Part 4 - 13: Testing and measurement
IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-2 Flicker BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3 Immunity Electrostatic Discharge (ESD) BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2 Radiated Immunity (R
Test: Test Methods1: Immunity (continued) Radiated Immunity (RFI) IEC 61000-4-3; BS EN/EN 61000-4-3; AS/NZS 61000.4.3; SANS 61000-4-3 Electrical Fast Transient/ Burst (EFT) IEC 61000-4-4; BS EN/EN 61000-4-4; AS/NZS 61000.4.4; SA
IEC 61000-3-2:2019 + A1:2021) Electromagnetic compatibility (EMC) – Part 3-2: Limits -Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) (IEC 61000-3-2:2018 + A1:2020 + ISH1:2021 ) Single phase ≤ 16 A
Test Technology: Test Method(s) 2: Common Technical Standards for Machines and Mechanisms S2-W-5 1 Guide to Documentation for Semiconductor Equipment Installation SEMI E6 1 Railway Immunity IEC 62236-3-21/ EN 50121-3-21 Gen
Test Technology: Test Methods 1, 2: Conducted Immunity EN 61000-4-6; IEC 61000-4-6 Magnetic Field Immunity EN 61000-4-8; IEC 61000-4-8 Voltage Dips, Short Interruptions, and Voltage Variations EN 61000-4-11; IEC 61000-4-11 Pr
Test Technology: Test Method(s) 1, 2: Generic / Product Family / Product Specific Standards (cont.) EN 60601-2-37 (2008) + A1 (2015), clause 202; IEC 60601-2-47 Ed. 2.0 (2012-02), clause 202; IEC 60601-2-49 (2011), clause 202; E
Parameter/Equipment Range CMC2, 5, 6 (±) Comments4 Surge Generator3 – Front Time (Rise / Fall Time) Duration Time (Time to Half-Value) Peak Voltage Peak Current Over/Under Shoot Phase Shift (50 Hz / 60 Hz)
2 Messung der elektrischen Eigenschaften von Erzeugungseinheiten und –anlagen [Flex A] Norm / Ausgabedatum Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angebe
Ackrediteringens omfattning Provningslaboratorier enligt SS-EN ISO/IEC 17025:2018 Dectron 2.0 AB Färjestaden Ackrediteringsnummer 10496 A014959-001 Elektrisk provning EMC Metod Parameter Provtyp Fält EN 55011:2016+A1:2017 +A11:2020+A2:2021
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN IEC 61000-4-11: 2021 Elektromagnetische Verträglichkeit (EMV) – Teil 4-11: Prüf- und Messverfah
Intek S.p.a. Via Mazzini, 75 25086 Rezzato BS Allegato al certificato di accreditamento n. 00855 rev. 5 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 21 Sede A Data: 16/07/2025 pag. 5 di 17 Prove di immunità/Immunity
Test Technology: Test Method(s) 1: Surge Immunity EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5 Conducted Immunity EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6 Power Frequency Magnetic Field Immunity EN 61000-4-8; IEC 61000
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 TUV RHEINLAND (GUANGDONG) LTD. 1/F & 2/F, Building 2, No.767 Tianyuan Road, Tianhe District Guangzhou 510650, Guangdong, People’s Republic of China Mrs. Tina Jiang Phone: +86 20 2839
T313, Eleforss Oy Liite 1, Akkreditoitu pätevyysalue Päätöksen numero: T313/M10/2026 Akkreditoinnin vaatimusstandardi: SFS-EN ISO/IEC 17025:2017 Akkreditointialue: Testauslaboratoriot Päätöspvm: 22.4.2026 Päätöksen viimeinen voimassa
Test Technology: Test Method(s) 1: Voltage Fluctuations and Flicker (International) EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-3-3; KS C 9610-3-3 Immunity Electrostatic Discharge (ESD) EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-2
Depart- ment Standard/in house procedure/Version Title of standard or in house procedure (deviations/modifications of standard) Test area/ reductions EMC IEC 61000-3-12:2011 IEC 61000-3-12:2011+IS1:2012 IEC 61000-3- 12:2011+AMD1:2
IEC 61000-3-2; EN IEC 61000-3-2 V oltage Changes, V oltage Fluctuations, and Flicker IEC 61000-3-3; EN 61000-3-3 Industrial, Scientific, and Medical Equipment CFR 47, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; AS CISPR
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung EMV DIN EN 61000 -4-4: 2013-04; VDE 0847-4-4: 2013-04 Elektromagnetische Verträglichkeit (EMV) - Teil 4-4: Prüf- und
IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; KS 9610-3-2; SANS 61000-3-2 Voltage Fluctuations and Flicker IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; KS 9610-3-2; SANS 61000-3-3 Magnetic Fields IATA DGR Section 3.9.2.2 and P
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Department Standard / in house procedure / Version Title of standard or in house procedure Test area / Reduct
Parameter/Range Frequency CMC2, 3 (±) Comments Current Probe/Injection Probe Calibration Fixture – VSWR (Linear) Insertion Loss (dB) ∆ Insertion Loss (dB) 10 Hz to 10 MHz (>10 to 400)
IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2 Flicker EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-2 Immunity ESD EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2 Radiated Immunity EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 6100
Test(s) Test Method(s) 1: Japan (continued) J55014-1(Except Section 4.2 Discontinuous disturbances test); J55015; J55032 Harmonics IEC/EN 61000-3-2; BS EN 61000-3-2; AS/NZS 61000.3.2 Flicker IEC/EN 61000-3-3; BS EN 61000-3-3; AS/N
IEC61000-4-6 Power Meter/Sensor3, 8 – Calibration Factor Linearity VSWR 9 kHz to 6 GHz 10 MHz to 18 GHz 50 MHz to 26.5 GHz (26.5 to 40) GHz 9 kHz to 6 GHz 10 MHz to 18 GHz 50 MHz to 40 GHz 9 k
Test Technology: Test Method(s) 1: Generic and Product Family Standards IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-4; IEC 61547; IEC 61326-1; IEC 61326-2-6; IEC 60601-1-2 (excluding Proximity magnetic fields); EN 61
Showing labs 1–50 of 268. Use pagination below to see more.