Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

ISO 16750-3 Accredited Testing Labs in United States

14 laboratories in United States are accredited by A2LA to perform ISO 16750-3 testing. We don't know yet whether 4 of them take outside work. From the accredited scope text: “ISO 16750-3; CEI IEC 255-21-1; SAE J1455, Sections 4.10 and 4.12; SAE J575, Section 4.2; RTCA/DO-160 (D/E/F/G), Section 8; US CAR-2, Sections 5.4.6 and 5.8; EIA-364-28; GMW 3172, Section 9.3; IACS-E10” “ISO 16750-3 (2003, 2007, 2012, 2023); ISO 16750-3; UN Regulation No. 116 point 6.4.2.8; UN Regulation No. 163 point 7.2.8; UN Regulation No. 162 Annex 6 point 3.8; UN Regulation No. 97 point 7.2.8; GM” “ISO 16750-3 (2012, 2023)” “ISO 16750-3 section 4.3 Mechanical Loads Hardness ASTM D2240, Shore A and D Durometer Hardness ASTM D3363 Film Hardness by Pencil Test ISO 868 Plastic and Ebonite – Determination of Indentation Hardne”

Labs
14
Primary AB
A2LA14 labs

Accredited Labs

Element Materials Technology Detroit – Warren 11 Mile

Warren, MI, US

Scope

ISO 16750-3 section 4.3 Mechanical Loads Hardness ASTM D2240, Shore A and D Durometer Hardness ASTM D3363 Film Hardness by Pencil Test ISO 868 Plastic and Ebonite – Determination of Indentation Hardness by Means of a Durometer (Shor

View lab

KEA Technologies

Littleton, MA, US

Scope

ISO 16750-3 (Section 4.3)

View lab

Element Materials Technology Fremont Newark

Fremont, CA, US

Scope

ISO 16750-3; MIL-STD-810; NHTSA Vol 78 No. 89; AREMA Communications & Signals Manual 2022, Section 11; EN 50125; ST/SG/AC.10/11/Rev. 7 Section 38.3; IEC 60571;IEC 62498 Seismic / Vibration Servo Hydraulic Sine, Random

View lab

DATASYST Engineering & Testing Services

Delafield, WI, US

Scope

ISO 16750-3 Durability/Mechanical Force up to 30,000 lbs Displacement up to 10 in Velocity 35 in/s MIL-STD-1344A 2009, 2010 Accelerated Exposure - Controlled Irradiance Environmental Simulation Temperature (-73 to 177) ºC S

View lab

Packaging Compliance

Billerica, MA, US

Scope

ISO 16750-3; ANSI C136.31 Mechanical Shock (0.5 g to 50 000 g (peak)) (0.2 ms to 75 ms) MIL STD 167, 202, 810, 883; RTCA/DO-160; IEC 60068-2-31, 60068-2-55, 60068-2-27, 60601-1-11, 60721-3-4, 60601-2-24 Shipping Simulation (1

View lab

Intertek Testing Services NA

Plymouth Township, MI, US

Scope

ISO 16750-3 Section 4.1; LV 124; VW80000; GS 9503 Mechanical Shock 2 (0 to 1,500) G (0 to 40) ms MIL-STD-810 Method 516; IEC 60068-2-27; GMW 3172 Sections 9.3.3, 9.3.4, & 9.3.5; DC-10611 Section 6.2.2; CS.00056 S

View lab

Elite Electronic Engineering

Downers Grove, IL, US

Scope

ISO 16750-3; CEI IEC 255-21-1; SAE J1455, Sections 4.10 and 4.12; SAE J575, Section 4.2; RTCA/DO-160 (D/E/F/G), Section 8; US CAR-2, Sections 5.4.6 and 5.8; EIA-364-28; GMW 3172, Section 9.3; IACS-E10, Test 7; FAA AC 150/5345-46

View lab

Element Materials Technology St. Paul

St. Paul, MN, US

Scope

Test(s): Test Method(s): Measuring Compressive Properties of Thermal Insulations ASTM C165 Breaking Load and Flexural Prop. of Block- Type Thermal Insulation ASTM C203 Cellulose Fiber Insulating Board ASTM C209 (Except Flame

View lab

APTIV WESTFIELD TEST

Westfield, IN, US

Scope

ISO 16750-3 (2003, 2007, 2012, 2023); ISO 16750-3; UN Regulation No. 116 point 6.4.2.8; UN Regulation No. 163 point 7.2.8; UN Regulation No. 162 Annex 6 point 3.8; UN Regulation No. 97 point 7.2.8; GMW 3172 (2008, 2010) [p. 9.3.1

View lab

Element Materials Technology Burton

Burton, MI, US

Scope

ISO 16750-3; JDQ 53.3; JIS D 1601; MIL-STD-202(G,H) methods 201, 204; MIL-STD-810(G,H) method 514; Nissan 28401NDS01; SAE J 1455; TSC 7000G; USCAR-2 UNECE R100 rev3 section 9A Mechanical Shock Electro-dynamic vibration tables

View lab

ZF Global Electronics - Validation

Farmington Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 16750-3; PF-9688; CS-11982; DC-10611; 9.90111/02; CS-00056; ES-5F9T-14A626-AA; ES-BT4T-13D061-AA; CETP00.00-E-412; GMW 3172; TSC7000G; TSC0511G; 7796Z-FC0T-P000; 7794Z-T5A-J810-M1; 9.90110; ES 95400-10; ES95910-93; ME

View lab

Kostal of America Test

Troy, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 16750-3 ISO 16750-4 IEC 60068-2-14 IEC 60068-2-30 IEC 60068-2-70 USCAR-21 SAE J1211 Force* (0.05 to 500) N22 PF11109 SAE USCAR 2 Torque* 0.05 Ncm to 3 Nm3 PF 11109 Vibration (Sine, Random, and Shock) Tempe

View lab

leggett & platt

Detroit, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 16750-3; JDQ 53.3; JIS D 1601; MIL-STD-202 (G, H) Methods 204; MIL-STD-810 (G, H) Methods 514 Microscopic Evaluation Microsections Analysis Visual Examination (5x to 100x) IPC-TM-650 (Methods 2.1.1, 2.1.2, 2.1.5, and 2.1.1

View lab

Robert Bosch

Plymouth, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 16750-3 (2012, 2023)

View lab

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches