Anatek Labs, Inc.
Spokane, WA, US
American Association for Laboratory Accreditation (A2LA) is an accreditation body in the United States. It is one of several such bodies there, so an American lab may hold its accreditation from a different one. This directory lists 3,537 laboratories holding active ISO/IEC 17025 accreditation from A2LA in 64 countries, 2,549 of them in the United States. Official site: www.a2la.org.
Each type-of-testing page lists the labs of every accreditation body.
Spokane, WA, US
Draper, UT, US
Greendale, WI, US
ASTM E1019, ASTM E1409, ASTM E1941; ISO 15350, ISO 15351; BS EN ISO 9556, BS EN ISO 10720, BS EN ISO 10276 Optical Emission Spectroscopy (DR-OES, GD-OES) (Iron, Steel, Alloy Steel, Tool Steel, Stainless Steel, Nickel, Cobalt, Cop
Harrisburg, PA, US
ASTM D346 Gross Calorific Value of Coal and Coke ASTM D5865 Instrumental Determination of Carbon, Hydrogen, and Nitrogen in Laboratory Samples of Coal and Coke ASTM D5373 Standard Practice for Preparing Coal Samples for Analysis AST
Ithaca, NY, US
MD-SOP-1004 MD-SOP-1005 MD-SOP-1006 MD-SOP-1007 MD-SOP-1009 MD-SOP-1010 MD-SOP-1015 MD-SOP-1031 MD-SOP-1032 MD-SOP-1033 MD-SOP-1053 Equine Arteritis Virus Equine Herpesvirus 1 Equine Herpesvirus 4 Equine Rhinitis A Virus Equi
Anaheim, CA, US
Morgan Hill, CA, US
Morgan Hill, CA, US
NIST TMAS _______________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve
Ashland, VA, US
USQ04AW04 or USQ04AW05 – internal calibration procedure Note: calibration typically performed at 40 °C USQ04AW03 – note: calibration typically performed at 20 °C. USQ04AW06 internal calibration procedure Density
Farmers Branch, TX, US
ASTM E1444/E1444M; ASME Section V Art. 7; AWS D1.1/D1.1M, D1.2/D1.2M, D1.5/D1.5M; API 1104, 6A; MIL-STD-1949 (Cancelled 1993); ISO 17638; NAVSEA T9074-AS-GIB-010/271 Penetrant Examination Visible and Fluorescent ASTM E165/E165M, E12
Auburn Hills, MI, US
ISO-16750-2 ( excluding sections 4.11 & 4.12); GMW 3172 Sections 8.2 & 9.2 (excluding section 9.2.16) Electrical Testing ISO 21498-2; ISO 21780 Automotive & Vehicle Product Specific Standards UN-Regulation No. 10; E/ECE/324/Add.
Westfield, IN, US
Newport News, VA, US
Sunnyvale, CA, US
Byron Center, MI, US
ASTM D751 Section 33-36, D2261, D5735-95 (2001); CFFA 16b Tear Strength of Fabrics: Trapezoid Method ASTM D751 Section 37-40, D5587, D5733-99; CFFA 16c Volatility CFFA 18 Wyzenbeek Abrasion ASTM D4157, D3597 Section 6.4; CFFA 1a
Bloomsburg, PA, US
Tonawanda, NY, US
ASTM E1417/1417M, ASTM E165/E165M Radiographic Examination Gamma and X-Ray, Film and Digital ASTM E94/E94M, ASTM E1742/1742M, ASTM E2033 Ultrasonic Testing Contact – Straight Beam and Angle Beam, and Phased Array AMS STD-2154,
Chandler, AZ, US
MIL-STD-462; RE01, RE02, RE03; MIL-STD-462D; RE101, RE102; MIL-STD-461E; RE101, RE102; MIL-STD-461F; RE101, RE102; MIL-STD-461G; RE101, RE102 Electrostatic Discharge 25 kV SAE J1113 Base; SAE/USCAR Initiator Requirements (Para. 3
Marietta, GA, US
ASTM E1479 Lead by Inductively Coupled Plasma (ICP) ASTM E1613 (Withdrawn in 2021) Soluble Metals ASTM F963-17 (Section 4.3.5.2 and Section 8.3); ASTM F963-23 (Section 4.3.5.2 and Section 8.3) Determining Lead Content in Substrates or
Tempe, AZ, US
IEC 61427-2 Secondary cells and batteries USABC Battery Test Manual for Electric Vehicles; for Photovoltaic Energy Systems (PVES) – General Requirements and Methods of Test, 2015; UL 1974 Section 18.7 IEC 61427-2; IEC 6
Greer, SC, US
ASTM E4 Load cells; the range for testing machines in tension is only to 60 000 lbf. ASTM E4 Calibration of Force Gages, Load Cells, Dynamometers & Cable Tensiometers 3 Up to 600 lbf (0 to 500) lbf (0 to 2000) lbf (
Sacramento, CA, US
ASTM E18
Sanford, FL, US
ASTM E4 Calibration of Force Gages, Load Cells, Dynamometers & Cable Tensiometers 3 Up to 600 lbf (0 to 500) lbf (0 to 2000) lbf (0 to 5000) lbf (0 to 25 000) lbf 0.02 % 0.32 lbf 1.1 lbf 3.0 lbf 9.0
Bartlett, TN, US
ison to Class 1 weights Comparison to Class F weights VI. Thermodynamics Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Temperature Measuring Equipment3 – Liquid in Glass Thermometers, Dial, RTDs, & Thermo
Tempe, AZ, US
ASTM E18 V. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measuring Equipment 3 Liquid in Glass Thermometers, Dial, RTDs, & Thermocouples (-40 to 200) °C (200 to 6
Butler, PA, US
ASTM E4 w/ standard/ dead weights ASTM E4 w/ proving rings ASTM E4 w/ S beam load cell ASTM E4 w/ load cell
Madison Heights, MI, US
CETP-00.00-E-412 Acoustics & Vibration BSR (Buzz, Squeak and Rattle) Hemi-Anechoic Room; MB Dynamic Silver Quiet Shaker System, HEAD Acoustics ArtemiS Suite Software and SQoBold Frontend with BHS II, HEAD Acoustics HSU III.2 Bi
Dayton, OH, US
ASTM F1044, ASTM F1160; PSA04-032, PSA04-050 Microhardness (Vickers 300 gf) ASTM E384; PSA04-011 Tensile Testing of Coatings ASTM F1147, ASTM C633; PSA04-001 Rockwell Superficial Hardness (15N) ASTM E18; PSA04-008 Abrasion A
Knoxville , TN, US
Warren, OH, US
ISO 10605 (2001, 2008, 2023), Sections 8 and 9; GMW3097 (June 2015, March 2019, Dec 2022, Feb 2024, May 2025), Sections 3.6.1, 3.6.2, and 3.6.3 RF Radiated and Conducted Emissions CISPR 25 (2016, 2021), Sections 6.3, 6.4, and 6.5; CIS
Westfield, IN, US
IEC 60068-2-17 (2023); IEC 60068-2-17; ISO 16750-4 (2006, 2010, 2023); ISO 16750-4; ISO 20653 (2006, 2013, 2023); ISO 20653; GMW 3172 (2008, 2010) [p. 9.5.2, 9.5.3, 9.5.4, 9.5.5]; GMW 3172 (2012, 2014, 2015, 2018, 2022, 202
Highlands Ranch, CO, US
Knoxville, TN, US
Calvert, AL, US
ASTM E112 ASTM E45 Microstructure Metals Handbook Volume 8 Energy-Dispersive Spectroscopy (EDS, SEM) Semi-Quantitative ASTM E1508; WI 8762 Preparation Method – Metallographic Preparation ASTM E3 Micro and Macr
East Chicago, IN, US
ASTM E18, A370; SAE J417 Vickers: HV 200gf, 300gf and 500gf ASTM E384 Knoop: HK 200gf, 300gf and 500gf ASTM E384 Impact Tests: Lab/Location Test Test Method R&D Charpy Impact ASTM E23, A370 Drop Weight Tear Test
Pittsburgh, PA, US
ASTM E331 Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference ASTM E547 Standard test method for water penetration of exterior windows, skylights,
Edgewood, NY, US
AAMA 1701.2 Voluntary standard for utilization in manufactured housing for primary windows and sliding glass doors AAMA 1702.2 Voluntary standard for utilization in manufactured housing for exterior passage doors swinging AAMA/NPEA/NSA
Lithia Springs, GA, US
ASTM B117 Standard Practice for Operating Salt Spray (Fog) Apparatus ASTM E8/E8M Standard Test Methods for Tension Testing of Metallic Materials ASTM E283/E283M Standard test method for determining rate of air leakage through exterior wi
West Palm Beach, FL, US
AAMA/WDMA/CSA; 101/IS.2/A440 North American Fenestration Standard/ Specification for windows, doors and Skylights AAMA 501 Methods of test for exterior walls AAMA 502 Voluntary specification for field testing of newly installed fen
FRESNO, CA, US
ASTM E721 Standard test methods of conducting strength tests of panels for building construction (sections 11, 14 and 15 only, except section 14.2.3) ASTM E283/E283M1 Standard test method for determining rate of air leakage through exte
FRIDLEY, MN, US
ASTM E283/E283M Standard test method for determining rate of air leakage through exterior windows, curtain walls, and doors under specified pressure differences across the specimen ASTM E330/E330M Standard test method for structural p
KENT, WA, US
ASTM E283/E283M 1 Standard test method for determining rate of air leakage through exterior windows, curtain walls, and doors under specified pressure differences across the specimen ASTM E330/E330M 1 Standard test method for structura
LAKE FOREST, CA, US
ASTM E329 Standard specification for agencies engaged in construction inspection, testing, or special inspection (sections 8-12) ASTM E699 Standard specification for agencies involved in testing, quality assurance and evaluating of ma
PLANO, TX, US
ASTM E72 Standard test methods of conducting strength tests of panels for building construction ASTM E283/E2831 Standard test method for determining rate of air leakage through exterior windows, curtain walls, and doors under specified
York, PA, US
ASTM E935 Standard test methods for performance of permanent metal railing systems and rails for buildings ASTM E1105 1 Standard test method for field determination of water penetration of installed exterior windows, skylights, doors, an
Research Triangle Park, NC, US
GSMA TS.11: Device Field and Lab Test Guidelines GSMA TS.40: MioT Field and Lab Test Cases AT&T Document 10776: Lab and Field Test Requirements for Terminal Unit Acceptance AT&T Device Acceptance: Field and Lab Test Description
New Kensington, PA, US
ASTM E1251, E716; SOP-03QNT-004, -005; SOP-48CERT-005 Spectrochemical Reference Material Analysis by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) (Ag, As, B, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, Hg, In,
Alcoa, TN, US
ASTM B557 r-value for Sheet Metal ASTM E517 n-value of Metallic Sheet Materials ASTM E646 Tension Testing of Metallic Materials ASTM E8/E8M Chemical Testing Analysis of Aluminum and Aluminum Alloys by Spark Emission Spectrome
Lancaster, PA, US
ASTM E1251 Optical Emission Spectrometric Analysis of Aluminum and Aluminum Alloys by the Argon Atmosphere, Point-to-Plane, Unipolar Self-Initiating Capacitor Discharge (B, Be, Bi, Ca, Cd, Cr, Cu, Fe, Ga, Li, Mg, Mn, Na, Ni,
West Seneca, NY, US
ASTM E8, A370; API 1104; New York State Steel Construction Manual (NYSSCM); ASME Section IX; AWS B2.1, B4.0, D1.1, D1.2, D1.9; AASHTO/AWS D1.5, D1.6, D14.1, D15.1 Bend ASTM E190, A370; API 1104; New York State Steel Construction
Showing labs 201–250 of 3,537.
Each lab page shows which of its certificates are active.
Search covers every A2LA lab we hold, filtered to this body, and narrows further by country, city or a term from the scope text itself.
Search A2LA accredited labs