EN 55016-2-1 Accredited Testing Labs Worldwide
See all 115 labs worldwide for EN 55016 (any part)
Part 1-1: 1 lab · Part 1-2: 6 labs · Part 1-3: 2 labs · Part 1-4: 8 labs · Part 1-6: 1 lab · Part 2-1: 102 labs and 4 more parts
102 accredited laboratories in 11 countries hold EN 55016-2-1 in their accredited scope. We don't know yet whether 46 of them take outside work. Primary accreditors include Deutsche Akkreditierungsstelle, Polish Centre for Accreditation, Italian Accreditation Body.
Available in 11 Countries
Sample labs
EN 55016-2-1 Oulu (Yrttipellontie), Salo Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical transient conduction along supply lines only ISO 7637-2:2004 5.6.1 Test pulse 1 5.6.2 Test pulses 2a and 2b 5
EN 55016-2-1:2004 + A1:2005 EN 55016-2-1:2009 + A1:2011 EN 55016-2-1:2014 + A1:2017 ISM Equipment EN 55011:1998 + A1:1999 + A2:2002 IT Equipment Laboratory Equipment EN 55011:2007 + A2:2007 Medical/Dental Equipment EN 55011-2009
EN 55016-2-1 (2014); EN 55016-2-3 (2014); CISPR 11 (2024); EN 55011 (2016); EN 55011:2016/A1:2017; EN 55011:2016/A11:2020; AS/NZS CISPR 11 (2016); KN 11 (RRA Announce 2016-79, Dec 19, 2016); KN 11; KS C 9811:2019; KS C 9816-2-1:2020;
EN 55016-2-1:2014+ +A1:2017) Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit – Teil 2-1: Verfahren zur Messung der hochfrequent
EN 55016-2-1, CISPR 16-2-1 EN 55011, CISPR 11 OS EMC.E.03 Electric- and electronic equipment Conducted Emissions Voltage method (LISN) 9 kHz – 30 MHz document 850 EN 55016-2-1, CISPR 16-2-1 EN 55011, CISPR 11 EN 55014-1, CISPR 14
EN 55016-2-1:2014 Wa ☒ LISN 400 VDC/4x200A 250 VAC/4x200A Mo ☒ LISN 400 VDC/4x50A 250 V AC/4x50A Ko ☒ LISN 350 VDC/4x32A 415VAC/4x32A EMV CISPR 16-2-1:2014 Specification for radio disturbance and im
EN 55016-2-1 UNE-EN 55016-2-1: 2009 UNE-EN 55016-2-1: 2009/A1:2012 UNE-EN 55016-2-1: 2009/A2:2013 Inmunidad a los transitorios eléctricos rápidos en ráfagas. UNE-EN 61000-4-4 Equipos de Tecnología de la Información Emisión conducid
Laboratorio di prova - ALSTOM Sesto San Giovanni - Divisione: Certification & Validation UNI CEI EN ISO/IEC 17025:2018 Via Fosse Ardeatine 120 20099 Sesto San Giovanni MI Revisione: 17 Sede A Data: 17/09/2025 pag. 1 di 2 ELENCO
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 60601-1-2:2015-11 PN-EN 60601-1-2:2015-11/A1:2021-07 PN-EN 50121-2:2017-06 PN-EN 50121-3-2:2017-04 PN-EN 50121-3-2:2017-04/A1:2019-07 PN-EN 50561-1:2013-12 PN-EN 55032:20
EN 55016-2-1:2014 + A1:2017 EMV CISPR 16 -2-1 ed. 3.1:2017 Specification for radio disturbance and immunity measuring apparatus and methods – Part 2-1: Methods of measurement of disturbances and immunity – Conducted disturbance me
EN 55016-2-1 NF EN 61000-6-3 NF EN 61000-6-4 NF EN 55011 / Monophasé, 16 A / 230 Vac Bande de fréquence : 150 kHz – 30 MHz. Puissance assignée de ≤ 3,7 kVA # Accréditation rendue obligatoire dans le cadre ré
EN 55016-2-1:2014 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit Teil 2-1: Verfahren zur Messung der hochfrequenten Störaussend
EN 55016-2-1 A La acreditación mantiene su vigencia hasta notificación en contra. La presente acreditación está sujeta a modificaciones, suspensiones temporales y retirada. Su vigencia puede confirmarse en https://www.enac.es/entidades-acr
Norm / Verfahren Ausgabe Titel der Norm oder des Verfahrens Prüfbereich / Einschränkung DIN EN IEC 61000 -6-3 2022-06 Elektromagnetische Verträglichkeit (EMV) - Teil 6 -3: Fachgrundnormen - Störaussendung von Geräten in Wohnbereic
EN 55016-2-1:2014 + A1:2017 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-1: Verfahren zur Messung der hochfrequent
EN 55016-2-1 NF EN 55016-2-1 Mesure de 150 kHz à 30 MHz Measurement from 150 kHz to 30 MHz
EN 55016-2-1 CISPR 16-2-1 Código Validación Electrónica: 19z3085mAEWB9TMDjp La acreditación mantiene su vigencia hasta notificación en contra. La presente acreditación está sujeta a modificaciones, suspensiones temporales y retirada. Su v
EN 55016-2-1 CISPR 22 EN 55022 CISPR 32 EN 55032 Tension RF exprimée en dBµV Dépassement ou non des niveaux limites fixés par les normes correspondantes Mesure sur site champ libre (Saint-Gauzens) et Toulouse Alimenta
EN 55016-2-1 1.3 Produc t Family Standards EMC DIN EN 54 -2/A1:2007 -01 Fire detection and fire alarm systems - Part 2: Control and indicating equipment Only Chapter 15.8.1: c), e), f), g) EMC DIN EN 298:2012 -11 Automatic
EN 55016-2-1:2014 + A1:2017 + AC:2020) Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-1: Verfahren zur Messung der
EN 55016-2-1:2019 VDE 0877-16-2-1:2019 EN 55016-2-1:2014 + A1:2017 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2- 1
EN 55016-2-1: 2017-10+AC:2020-09 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-1: Verfahren zur Messung der hochfre
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym PN-EN 61000-6-4:2008 PN-EN 61000-6-4:2008/A1:2012 PN-EN I
EN 55016-2-1:2009 + A2 2013 BS EN 55016-2-1:2014 + A1:2017 Excluding telecom ports according to Clause 9.5 EN 55022:1998 EN 55022:2010 BS EN 55032: 2012 BS EN 55032: 2015 + A1:2020 FCC CFR 47:Part 15B:2008 ANSI
EN 55016-2-1:2014 (EN 55016-2-1:2009 + A1:2011 + A2:2013) Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit – Teil 2-1: Verfahre
EN 55016-2-1:2009 UN Regulation No 10 Annex 13 PN-EN 55016-2-1:2009 Odporność pojazdów na szybkie elektryczne zaburzenia przejściowe/impulsowe przewodzone wzdłuż przewodów prądu przemiennego i stałego Metoda: badania stanow
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017- 12 PN-EN 55016-2-1:2014-09/AC:2020- 11 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020- 01 PN-EN 55016-2-2:2011 PN-EN IEC 61000-6-3:2021-08 PN-EN IEC 61000-6-4:2019-12 O
EN 55016-2-1 2019-11 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (CISPR 16-2-1:2014 + A1:2017)
EN 55016-2-1:2009-12 VDE 0877-16-2-1:2009-12 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2- 1: Verfahren zur Messung
EN 55016-2-1; VDE 0877-16-2-1: 2014 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit Teil 2-1: Verfahren zur Messung der hochfr
EN 55016-2-1; VDE 0877-16-2-1: 2019-11 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements Only condu
Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV CISPR 16 -1-1:2019 Specification for radio disturbance and immunity measuring apparatus and methods
EN 55016-2-1 (2019) Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit – Teil 2-1: Verfahren zur Messung der hoch- frequenten St
EN 55016-2-1:2015/A1:2018, CISPR 16-2-1:2014/AMD1:2017/Cor1:2020, EN 55016-2-1:2014/A1:2017/AC:2020 CEI EN 55016-2-3:2017/A1:2020, CISPR 16-2-3:2016/AMD1:2019, EN 55016-2-3:2017/A1:2019 CEI EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 Harmoniczne prądu Zakres: (0 – 16) A, n = 1, 2, ..., 50 PN-EN IEC 61000-3-2:2019-
EN 55016-2-1, CISPR 16-2-1 HE EMC.E.04 Conducted Emissions Voltage method (capacitive voltage probe) 150 kHz - 30 MHz EN 55022, CISPR 22 EN 55016-2-1, CISPR 16-2-1 HE EMC.E.05 Conducted Emissions Current method (current probe)
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 Urządzenia przemysłowe, naukowe i medyczne PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 Przyrządy powszechnego użytku, narzędzia elektryczn
EN 55016-2-1:2014-09, PN-EN 55016-2-1:2014-09/A1:2017- 12 PN-EN 55015:2019-11 Napięcie zaburzeń nieciągłych Zakres częstotliwości: (0,150 - 30) MHz Metoda bezpośrednia Discontinuous disturbance voltage Frequency range: (0,150 -
EN 55016-2-1 (Discontinuous disturbance not included) SO EMC.E.14 Radiated Emissions Full Anechoic Chamber Method (FACM) 1 GHz – 6 GHz 6001-1347-45xx CISPR 11 / EN 55011 CISPR 32 / EN 55032 CISPR 16-2-3 / EN 55016-2-3 (Discontinu
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN 61000 -4-6 VDE 0847-4-6:2014 Elektromagnetische Verträglichkeit (EMV) – Teil 4-6: Prüf- und
EN 55016-2-1:2014 EN 55016-2-1:2014/A1:2017 EN 55032:2015 EN 55032:2015/A11:2020 EN 55032:2015/A1:2020 EN 55014-1:2021 EN 55011:2016 EN 55011:2016/A1:2017 EN 55011:2016/A11:2020 EN 55011:2016/A2:2021 EN 55022:2010 Napięcia zabur
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROWN EQUIPMENT CORP. 410 Grand Lake Rd. Celina, OH 45822 Joe Knepper Phone: 419 629 2311 x16074 Email: joe.knepper@crown.com ELECTRICAL Valid To: March 31, 2028 Certificate Number
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06-06/A1:2020-01 Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Odbiorniki radiofoniczne i telewizyjne oraz
EN 55016-2-1:2014 EMV DIN EN 55016 -2-1: 2019 Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-1: Verfahren zur Mess
EN 55016-2-1:2014-09+ A1:2017-12 Urządzenia przemysłowe, medyczne i naukowe (PMN) wykorzystujące częstotliwości radiowe Industrial, scientific and medical (ISM) equipment using radio- frequencies PN-EN 55011:2016-05+A1:2017-05 +A2:
EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-1:2014-09/AC:2020-11 Natężenie pola elektromagnetycznego Częstotliwość: (0,0001 - 6) GHz oraz w miejscu instalacji / IN SITU Częstotliwość: (0,03 - 1) GHz
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN 60255 -26; VDE 0435-320:2014 Berichtigung 1:2014 Berichtigung 2: 2015 Messrelais und Schut
EN 55016-2-1:2014 + A1:2017 Single phase only IEC CISPR 16-2-3 2016+A1:2019 +A2:2023 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunit
EN 55016-2-1:2014 PB ) Except: CDNE method according to section 9. EMC CISPR 16 -2-3 :2010 + A1:2010 + A2:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of meas
EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02) Wersja strony: A
Showing labs 51–100 of 102. Use pagination below to see more.