EN 61000-4-3 Accredited Testing Labs Worldwide
164 accredited laboratories in 13 countries hold EN 61000-4-3 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, EN 61000-4-3 scope entries most often cover Radiated Emissions, Harmonics, Emissions in Air, Medical equipment, electrical safety and EMC, Electronic.
Available in 13 Countries
Top matrices for EN 61000-4-3
Top analytes for EN 61000-4-3
- Radiated Emissions (2)
- Harmonics (2)
- Emissions (1)
- Emissions (Radiated And Conducted) (1)
- Frequency Response (1)
- Harmonic Current (1)
- Harmonic Current Emissions (1)
- Conducted Emissions (1)
Sample labs
EN 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3 Electrical Fast Transient/ Burst IEC 61000-4-4; EN 61000-4-4; SANS 61000-4-4 Surge IEC 61000-4-5; EN 61000-4-5; SANS 61000-4-5 Conducted Immunity IEC 61000-4-6; EN 61000-4-6; SANS 6
EN 61000-4-3:2006 A 26 MHz to 1 GHz @ 20V/m + A1:2008 + A2:2010 1 GHz to 6 GHz @ 10V/m IEC 61000-4-3:2006 + A1:2007 + A2:2010 EN IEC 61000-4-3:2020 1.7 Immunity to Fast Transients/ EN 61000-4-4:2012
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ELEMENT MATERIALS TECHNOLOGY - MALVERN 100 Frobisher Business Park, Leigh Sinton Road Malvern WR14 1BX United Kingdom Ian Forshaw Phone: +44 (0)1684 571 700 Email: Ian.Forshaw@elemen
EN 61000-4-3 (2006) + A2 (2010); IEC 61000-4-3, Ed. 4.0 (2020-09); EN IEC 61000-4-3:2020; BS EN IEC 61000-4-3:2020; EN 61000-4-3 (2006) + A2 (2010); IEC 61000-4-3 Ed. 3.2 (2010-04) Electrical Fast Transient / Burst BS EN 61000-4-4 (
EN 61000-4-3: 2011 Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder (IEC 61000-4-3:2006 + A1:2007 + A2:2010); Deutsche Fassung EN 61
EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3 Electrical Fast / Transient Burst IEC/EN 61000-4-4; BS EN 61000-4-4 Surge Immunity IEC/EN 61000-4-5; BS EN 61000-4-5 Conducted Immunity IEC/EN 61000-4-6; BS
EN 61000-4-3: 2020 EMC – Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test EMV DS/EN 61000-4-4: 2012 EMC – Part 4-4: Testing and measurement techniques – Electrical fast t
TUV ITALIA SrL Via Brandizzo 123 10088 Volpiano TO Allegato al certificato di accreditamento n. 00077 rev. 7 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 10 Sede B Data: 19/03/2025 pag. 8 di 62 Prova di immunità a on
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens1 Prüfbereich / Einschränkung 1 Grundnormen EMV DIN EN 61000-4-2; VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil 4-2: Prüf- und Me
EN 61000-4-3 Electrical Fast Transient / Burst IEC 61000-4-4; EN 61000-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5 Conducted Immunity (0.15kHz- 230MHz, 20V) IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field Immunity IEC 6
EN 61000-4-3:2006+A1:2008+A2:2010; KS C 9610-4-3; JIS C 61000-4-3 Electrical Fast Transient / Burst EN 61000-4-4; IEC 61000-4-4; KS C 9610-4-4; JIS C 61000-4-4 Surge Immunity EN 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; JIS C 61000
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HCT CO., LTD. 74, Seoicheon-ro 578 Beon-gil, Majang-Myeon Icheon-Si, Gyeonggi-Do, South Korea Ms. Myounglim Lee Phone: +82-(0)31-645-6918 Email: sm@hct.co.kr ELECTRICAL
EN 61000-4-3 Electrical Fast Transient / Burst IEC 61000-4-4; EN 61000-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5
EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3 Electrical Fast Transient (EFT) IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5
EN 61000-4-3; GB/T 17626.3; AS/NZS 61000.4.3; CNS 14676-3; BS EN 61000-4-3; BS EN IEC 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3 Electrical Fast Transient IEC 61000-4-4; EN 61000-4-4; GB/T 17626.4; AS/NZS 61000.4.4; CNS 14676-4; BS
EN 61000-4-3; KS C 9610-4-3 Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4
EN 61000-4-3) Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder (IEC 61000-4- 3:2006 + A1:2007 + A2:2010) bis 30 V/m, 3 m max. Pr
EN 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3 EFT BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4 Surge (*see Table #1 limitation list below) BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5
EN 61000-4-3; AS/NZS 61000.4.3; SANS 61000-4-3 Electrical Fast Transient/ Burst (EFT) IEC 61000-4-4; BS EN/EN 61000-4-4; AS/NZS 61000.4.4; SANS 61000-4-4 Surge IEC 61000-4-5; BS EN/EN 61000-4-5; AS/NZS 61000.4.5; SANS 61000-4-5
Ausstellu ngsdatum: 02.04.20 26 Seite 10 von 24 Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EM V BS EN 60974-10:2014 +A1:2015 (EN 60974- 10:2014+A1
EN 61000-4-3 1; KS C 9610-4-31 Electrical Fast/Transient Burst (EFT) IEC 61000-4-4 1; EN 61000-4-4 1; KS C 9610-4-4 1 Surge IEC 61000-4-5 1; EN 61000-4-5 1; KS C 9610-4-5 1 Conducted Immunity IEC 61000-4-6 1; EN 61000-4-6 1
EN 61000-4-3:2021 Elektromagnetische Verträglichkeit (EMV) – Teil 4-3: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder Feldstärke ≤20 V/m (80 -1000 MHz) Feldstärke ≤10 V/m (1 -
Intek S.p.a. Via Mazzini, 75 25086 Rezzato BS Allegato al certificato di accreditamento n. 00855 rev. 5 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 21 Sede A Data: 16/07/2025 pag. 6 di 17 Gradi di protezione degli i
EN 61000-4-3; IEC 61000-4-3; BS EN IEC 61000-4-3 Electrical Fast Transient/Burst EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4
EN 61000-4-3:2006 + A1:2008 + A2:2010 Tampere Sähköiset ja elektroniset laitteet Testing and measurement techniques - Electrical fast transient/burst immunity test EN 61000-4-4:2012 EN 61000-4-4:2004 + A1:2010 Tampere Sähköiset ja e
EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-3; KS C 9610-4-3 Electrical Fast Transient/Burst EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-4; KS C 9610-4-4 Surge Immunity EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-5; AS IEC 61000
EN 61000-4-3:2006/A1:2008 EN 61000-4-3:2006/A2:2010 EN IEC 61000-4-3:2020 BS EN 61000-4-3:2006+A2:2010 BS EN IEC 61000-4-3:2020 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-freq
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung 1 Elektromagnetische Verträglichkeit (EMV) 1.1 Grundnormen EMV DIN EN 61000 -3-2: 2019 -12; VDE 0838-2: 2019- 12
EN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3; SANS 61000-4-3; ISO 11452-1
EN 61000-4-3:2006 + A1:2008 + A2:2010 EMC* DIN EN 61000 -4-4; VDE 0847-4-4:2013-04 IEC 61000-4-4:2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHENZHEN MICROTEST CO., LTD. 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue Xinhe Community, Fuhai Street, Bao'an District Shenzhen, Guangdong, People’s Republic of China Ms.
EN 61000-4-3 (10V/m @ 6GHz); BS EN 61000-4-3 EFT/Burst IEC/EN 61000-4-4; BS EN 61000-4-4 Surge IEC/EN 61000-4-5; BS EN 61000-4-5 Conducted Immunity IEC/EN 61000-4-6; BS EN 61000-4-6 Magnetic Field IEC/EN 61000-4-8; BS EN 61000-4
EN 61000-4-3; IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3 EFT/Burst EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4 Surge EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5 Conducted Immunity EN 61000-4-6; IEC 61000-4-6; BS EN 610
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkung zum Prüfverfahren EMV IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Elect
Assessment Manager: CA Page 1 of 3 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 25241 Accredited to ISO/IEC 17025:2017 Paxton Acces
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHENZHEN TIANSU CALIBRATION AND TESTING CO., LTD. Building 8, Changjiang Cable Industrial Park, 56 Xinwang Road, Longgang District Shenzhen, 518116, People’s Republic of China Harry Li
Norm/Hausverfahren/ Version Titel der Norm oder des Hausverfahrens Standort DIN EN 50491-2 2015-10 EN 50491-2 2010-03 +A1:2015-04 Allgemeine Anforderungen an die Elektrische Systemtechnik für Heim und Gebäude (ESHG) und an Systeme d
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ANALYSIS AND MEASUREMENT SERVICES CORPORATION (AMS) AMS Technology Center 9119 Cross Park Drive Knoxville, TN 37923 Eternity Perry Phone 865 691 1756 Ext: 168 Email: eternity@ams-c
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EMTEK (SHENZHEN) CO., LTD. Building 69, Majialong Industry Zone Nanshan District, Shenzhen Guangdong, People’s Republic of China Ms. Lisa Wang Phone: +86 755 26954280 Email: wangli@
Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren/ Einschränkungen 1 Grundnormen EMV DIN EN 61000-4-2:2009-12 VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) -
EN 61000-4-3 (VDE 0847-4-3) 2003-11 Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegenhochfrequente elektromagnetische Felder (IEC 61000-4- 3:2002 + A1:2002); Deutsche Fassu
EN 61000-4-3; KS C 9610-4-3; IEC 60255-22-3; IEEE C37.90.2; IEC 61000-4-39 Electrical Fast Transient/Burst 3 IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 60255-22-4
EN 61000-4-3:2006 +A1: 2008 +A2: 2010) Elektromagnetische Verträglichkeit (EMV) - Teil 4- 3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder (IEC 61000-4-3:2006 + A1:2007 + A2:2010)
EN 61000-4-3; KS C 9610-4-3 Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4 Surge Immunity IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5 Conducted Immunity IEC 61000-4-6; EN 61000-4-6; KS C 9610-
1 Elektromagnetische Verträglichkeit (EMV) [Flex A] 1.1 Grundnormen EMV IEC 61000 -4-2:20 08 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV DIN EN
Test Technology: Test Method(s) 2,3,4: Radiated Immunity (up to 6 GHz, 10V/m) IEC/EN/EN IEC 61000-4-3 Electrical Fast Transient/Burst IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Conducted Immunity IEC/EN/EN IEC 61000-4-6 Pow
EN 61000-4-3:2006 + A1:2008 + A2:2010) Elektromagnetische Verträglichkeit (EMV) Teil 4: Prüf- und Messverfahren Hauptabschnitt 3: Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder. EMV DIN EN 61000 -4-4:201
EN 61000-4-3; BS EN IEC 61000-4-3; EN IEC 61000-4-3; GB/T 17626.3
EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; SANS 61000-4-3 Electrical Fast Transient (EFT) EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; SANS 61000-4-4 Surge IEC 61000-4-5; EN 61000-4-5; BS EN 61000-
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 GREEN MOUNTAIN ELECTROMAGNETICS, INC. 219 Blake Roy Road Middlebury, VT 05753 Kyle R. Kowalczyk Phone: 802 388 3390 email: gme@gmelectro.com Website: www.gmelectro.com
Showing labs 1–50 of 164. Use pagination below to see more.