IEC 61000-4-39 Accredited Testing Labs Worldwide
58 accredited laboratories in 13 countries hold IEC 61000-4-39 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.
Available in 13 Countries
Top analytes for IEC 61000-4-39
- Harmonics (2)
Sample labs
IEC 61000-4-39:2017; EN/IEC 61000-4-39 EMC – Automotive CISPR 25 Ed 4.0:2016; CISPR 25 EMC – Railway EN 50121-3-2:2016+A1:2019; EN 50121-3-2 EMC – MIL/Aerospace RTCA DO-160G; RTCA DO-160; Section 21.4, Section 21.5, Section 20.5,
IEC 61000-4-39:2017 Electromagnetic compatibility (EMC) – Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test Prüfbereich: 9 kHz bis 26 MHz 2 Fachgrundnormen EMV DIN EN IEC 61000-6-1;
IEC 61000-4-39; (only 9kHz~26MHz) Harmonics and Flicker Current Harmonics IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; GB 17625.1; IEC 61000-3-2:2005+A1:2008+A2:2009; EN IEC 61000-3-2:2019; IEC 61000-3-12;
IEC 61000-4-39 (Excluding 5.5,6.2, 7.2, 8.6)
IEC 61000-4-39; EN 61000-4-39 Generic, Product Family and Industry Specific EMC Standards IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; CISPR 14-2; EN 55014-2; EN IEC 55014-2; IEC 6154
IEC 61000-4-39 HE EMC.I.15 Radiated disturbances Immunity 20 MHz – 2.7 GHz Up to 30 V/m IS Radiated Susceptibility testing EN-IEC 61000-4-3, 2004/104/EC, 97/24/EC, ECE Regulation 10 HE, MoLo EMC.I.21 Electrostatic discharge Imm
IEC 61000-4-39 Multimedia Equipment CISPR 35; EN 55035; BS EN 55035
IEC 61000-4-39 (Medical Devices only) EN 61000-4-39 (Medical Devices only) V oltage Dips, Short Interruptions, and V oltage Variations IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11 Generic/Product Family Standards and I
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017-06 Prüfungen 9 kHz – 26 MHz
IEC 61000-4-39:2017 Electromagnetic compatibility (EMC) – Part 4-39: Testing and measurement techniques – Radiated fields in close proximity – Immunity test no test according to clause 7
IEC 61000-4-39 2017-03 Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test Frequency range 9 kHz – 26 MHz, only
IEC 61000-4-39:2017 Elektromagnetische Verträglichkeit (EMV) - Teil 4-39: Prüf- und Messverfahren - Gestrahlte Felder im Nahbereich - Prüfung der Störfestigkeit (IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 Electromagnet
IEC 61000-4-39 Electrical Fast Transient/Burst 3 IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 60255-22-4
IEC 61000-4-39: 2017 Electromagnetic compatibil ity (EMC) – Part 4-39: Testing and measurement techniques – Radiated fields in close proximity – Immunity test EMV DIN EN 61000-4- 39:2019-04 Elektromagnetische Verträglichkeit (EMV) -
IEC 61000-4-39:2017) Keine gestrahlten HF-Felder von 380 MHz bis 6 GHz
Test Technology: Test Method(s): Immunity (cont.) Voltage Dips, Short Interruptions Line Voltage Variations IEC/EN 61000-4-11; IEC 61000-4-29; EN 61000-4-29 American National Standard for Evaluation of Wireless Coexistence
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 Magnetfelder im Nahbereich 9 kHz – 26 MHz 1.2 Fachgrundnormen EMV DIN EN IEC 61000 -6-1:2019 -11 Elektromagnetische Verträglichkeit (EMV) - Teil 6-1: Fachgrundnormen
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 Nur Frequenzbereich bis 26MHz EMV IEC 61000 -4-39:2017 Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proxim
IEC 61000-4-39; EN 61000-4-39; KS C IEC 61000-4-39
IEC 61000-4-39; IEC 61000-4-39 Generic and Product Family Standards IEEE 1613; IEC 60533; IEC 61850-3; BS EN 61850-3; IEEE 37.90.1; IEC 60092-504 (Section 5: Table 1, Items 4a, 4b, 5, 11a & 11b only)
IEC 61000-4-39:2017-03 Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test Keine Störfestig- keitsprüfungen gegen gestrahlte HF-Felder nach den Abs
IEC 61000-4-39 EN / IEC 60601-1-2 Limité à 30 kHz 134,2 kHz 13,56 MHz U-VAR Matériels électroniques (1) EN 50130-4 EN 50155 /
Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV / EMC DIN EN 61000-4- 29:2001 Elektromagnetisch
IEC 61000-4-39 Marine Device DNVGL-CG-0339 Clause 14; IEC 60533 ITE/Telecom CISPR 24; EN 55024; BS EN 55024; SANS 224; CISPR 35; EN 55035; BS EN 55035; SANS 2335 Household Appliances CISPR 14-2; EN IEC 55014-2; BS EN IEC 55014-2;
IEC 61000-4-39:2017 (30 kHz, 134.2 kHz and 13.56 MHz only) A, C, E, G 20 Hz to 100 kHz DEF STAN 59-41 Part 3 Iss 1:1993 Maximum Field Strength: DRS01 170 dBT DEF STAN 59-41:1988 Issue 3 DEF STAN 59-41:Issue 3 and 5,
IEC 61000-4-39, EN 61000-4-39 (9kHz to 26 MHz); IEC 60601-1-2, EN 60601-1-2 UK- Emissions & Immunity BS EN 55011; BS EN 55015 (excluding 9kHz-30MHz); BS EN 55032; BS EN 55035; BS EN IEC 61000-3-2; BS EN IEC 61000-3-3; BS EN IEC 61000
IEC 61000-4-39:2017 9 kHz to 26 MHz Up to 65 A/m AC Mains: as in 1.1 1.15 Generic Standards EN 61000-6-1:2001 A, B EN 61000-6-1:2007 These Generic and Product EN 61000-6-
Fachbereich Norm / Prüfverfahren (Ausgabestand) Titel der Norm oder des Prüfverfahrens Einschränkung EMV IEC 61000 -4- 39:2017 Electromagnetic compatibility (EMC) – Part 4-39: Testing and measurement techniques – Radiated fields
IEC 61000-4-39: 2017 Electromagnetic compatibil ity (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test without the frequencies 26- 380 MHz and 380 MHz-6 GHz according to 5.5,
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 1.1.2 Fachgrundnormen EMV DIN EN IEC 61000-6-1 2019-11 Elektromagnetische Verträglichkeit (EMV) - Teil 6-1: Fachgrundnormen - Störfestigkeit für Wohnbereich, Geschäfts- u
IEC 61000-4-39; EN 61000-4-39; BS EN 61000-4-39; SASO-IEC-61000-4-39 Radiated Immunity (80MHz~6GHz, 10V/m@3m, 30V/m@1m) IEC 61000-4-3; EN IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; SANS 61000-4-3; SASO-GSO-IEC-61000
IEC 61000-4-39 EN 61000-4-39 Generic, Product Family and Industry Specific EMC Standards IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-7; EN 61000-6-7; CISPR 14-2; EN 550
IEC 61000-4-39 A EMC. I.13 Electric and electronic equipment Radiated immunity Magnetic field 9 kHz – 150 kHz up to 100 A/m 150 kHz – 26 MHz up to 30 A/m EN IEC 61000-4-39 A EMC. I.21 Electric and electronic equipment Elec
IEC 61000-4-39; EN 61000-4-39; BS EN 61000-4-39 RF TESTING USA FCC 47 CFR Part 15C (using ANSI C63.10:2020); FCC 47 CFR Part 15E (using ANSI C63.10:2020 or FCC KDB 905462 D02 v02); ANSI C63.10:2020 Canada RSS-GEN; RSS-210 (up
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 Für Prüfungen nach DIN EN 60601-1-2:2022-01 Frequenzen: 30 kHz, 134,2 kHz (0…150 kHz) und 13,56 MHz (10 kHz …120 MHz) 2 Fachgrundnormen EMV DIN EN 61000 -6-1:2007 -
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 bis 32 A Versorgungs- spannung EMV IEC 61000-4-39:2017 Electromagnetic Compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximit
IEC 61000-4-39:2017 Electromagnetic Compatibili ty (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test Only for frequency range < 26 MHz EMV DIN EN 61000-4-39:2019 (EN 61000-
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV DIN EN 61000 -4- 28:2009-12;VDE 0847-4-28:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil 4-28: Prü
IEC 61000-4-39:2017); Deutsche Fassung EN 61000-4-39:2017 Nur Inhomogene Magnetfelder 9kHz – 26 MHz. EMV IEC 61000 -4-39:2017 Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in
IEC 61000-4-39 Generic / Product Specific EMC Standards CISPR 24; EN 55024; CISPR 35: EN 55035; SANS 2335; KS C 9835:2019; ISO 11451-4; EN/IEC 12895; EN/IEC 13309; EN 12015; EN 12016; EN/ISO 13766; EN/ISO 14982; EN/IEC
IEC 61000-4-39 (up to 26 MHz); EN 61000-4-39 (up to 26 MHz) Generic and Product Family Standards CISPR 20; EN 55020; CISPR 24; EN 55024; CISPR 35; EN 55035; SANS 2335; IEC 61547; EN 61547; SANS 61547; IEC 61000-6-1; E
IEC 61000-4-39:2017); German version EN 61000-4-39:2017 ☐ ESS ☒ SB
IEC 61000-4-39:2017) Deutsche Fassung EN 61000-4-39:2017 Nur Störfestigkeit gegen Magnetfelder 9 kHz bis 26 MHz EMV IEC 61000-4-39: 2017 Electromagnetic Compatibil ity (EMC) – Part 4-39: Testing and measurement techniques – Radiated
IEC 61000-4-39; EN 61000-4-39; BS EN 61000-4-39 Wireless Coexistence ANSI C63.27:2017, ANSI C63.27:2021 Automotive EMC Conducted and Radiated Emissions CISPR 25; SAE J1113-41; SANS 225; UN ECE Regulation 10; ISO 14982; ISO 14982
IEC 61000-4-39; EN IEC 61000-4-39; GB/T 17626.39 Broadband Impulsive Conducted Disturbances CISPR 35; EN 55035 Generic and Product Specific EMC IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6
IEC 61000-4-39:2017); German version EN 61000-4-39:2017 Only frequency range 9kHz to 26 MHz 2 Generic Standard EMC DIN EN IEC 61000-6-1 2019-11 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard
T290/A21/2025 Liite 1 / Appendix 1 Sivu / Page 6(24) Vaatimus/Requirement SFS-EN ISO/IEC 17025:2017 30.10.2025 Päätöksen päiväys / Date of decision 31.12.2029 Päätöksen viimeinen voimassaolopäivä / Date of expiry www.finas.fi Voimassaoleva
IEC 61000-4-39:2017; EN/IEC 61000-4-39 EMC – Automotive CISPR 25 Ed 4.0:2016; CISPR 25
IEC 61000-4-39 (magnetic field only) Impulse Voltage Withstand Dielectric (AC or DC) (to 5 kV), Insulation Resistance Protective Bonding IEC 60255-5; EN 60255-5; IEC 60255-27; EN 60255-27
Testing field Standard / In- House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions EM C DIN EN 61000 -4-28: 2009-12 Electromagnetic compatibility (EM
Showing labs 1–50 of 58. Use pagination below to see more.