ISO 11452-2 Accredited Testing Labs Worldwide
244 accredited laboratories in 14 countries hold ISO 11452-2 in their accredited scope. We don't know yet whether 117 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, Italian Accreditation Body.
Available in 14 Countries
Sample labs
ISO 11452-2; FMC 1278; RI 114; GM GMW3097, Section 3.4.2 Electrical Transient Conduction Along Supply Lines ISO 7637-2; FMC 1278; CE 410/CI 220/CI 221; GMW3097, Sections 3.5.1 and 3.5.2 Electrical Transient Transmission by
Antennas (Antenna Factor): (cont.) Biconical, Hybrid, Dipole, Log Periodic Biconical, Hybrid, Log Periodic (GSCF) Antenna Symmetry, Balance 20 MHz to 1 GHz 30 MHz to 1 GHz 20 MHz to 1GHz
ISO 11452-2; ECE R10; BS ISO 11452-2; BS EN ISO 14982; EN ISO 14982; BS EN ISO 13766-1; EN ISO 13766-1; BS EN ISO 13766-2; EN ISO 13766-2; BS EN 15194; EN 15194; SAE J1113-21 (Section 7); VW TL81000 Bulk Current Injectio
ISO 11452-2:2004 1.2.3 Conducted Immunity UN Regulation no. 10 Revision 4. BCI 20 MHz to 400 MHz, 60 mA UN Regulation no. 10 Revision 5 UN Regulation no. 10 Revision 6 ISO 11452-4:2005 (substitution method only)
ISO 11452-2; GB/T 33014.2; ISO 13766-1; Q/LQB S-52; Q/JX 08140; BT/SGMWJ 08244.6 Magnetic Field Immunity (MFI) ISO 11452-8; Q/LQB S-52; Q/JX 08140; BT/SGMWJ 08244.8 Portable Transmitters ISO 11452-9; Q/LQB S-52; Q/JX 08140; BT/SGMW
ISO 11452-2 Bulk Current Injection (BCI) ISO 11452-4 Conducted Immunity on Power lines Supply Voltage transients ISO 7637-2 Conducted Immunity on Signal Lines ISO 11452-10 ISO 7637-3 (using CCC) Conducted Transient Emissions IS
ISO 11452-2; GB/T 33014.2; ECE R10; ECE R116; GB 34660; EN 13309; ISO 13766-1; EN ISO 14982; EN 13766-2 Road vehicles- Component test methods for electrical disturbances from narrowband radiated electromagnetic energy ISO 11452-
ISO 11452-2 Bulk Current Injection (BCI) ISO 11452-4 Immunity to Magnetic Fields ISO 11452-8 Portable Transmitters ISO 11452-9 Electrical Loads ISO 16750-2 Product EMC Standards I
ISO 11452-22; ISO 11451-22 Bulk Current Injection (BCI) (excluding TWC method) ISO 11452-42; ISO 11451-42 Magnetic Field Immunity (excluding Helmholtz coil) ISO 11452-8 Electrical transient conduction along supply lines
Testing field Standard / In- House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions EM C ISO 7637 -2:2011 Road vehicles – Electrical disturbances from
ISO 11452-2:2004, ISO 11452-2:2019 EMC Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular, Veicoli/Vehicles Denominazione della prova / Campi di prova Prove di immunit
ISO 11452-2:2019-01 Road vehicles – Component test methods for electrical disturbances from narrowband radiated electromagnetic energy – Part 2: Absorber-lined shielded enclosure Up to 8 GHz Without HV- System EMV ISO 11452-4:2020-0
ISO 11452-2:2019 Vehicle Component Immunity to Transients SAE J1113-11:2018; ISO 7637-2:2011 (12V Systems only) Screening Attenuation Measurements by Reverberation Chamber Method IEC 61726:2015 Screening Attenuation IEEE Std 2
ISO 11452-2 (2019); ISO 11452-4 (2015); ISO 11452-7 (2015); ISO 11452-8 (2015); ISO 11452-9 (2015); ISO 11452-10 (2015); ISO 10605 (2014); UNECE R10:2014; UN Regulation No. 10 Revision 6: 2019 Electricity Metering Equipment - Partic
ISO 11452-2:2019; ISO 11452-4 (2020); ISO 11452-7 (2003); ISO 11452-8 (2015); ISO 11452-10 (2009); Ford ES-XW7T-1A278-AC; FMC 1278 (2016); GMW 3097; DC-10614 Military / Avionic MIL-STD 461G RE102; RTCA/DO-160G Section 20 (Equipment
ISO 11452-2
ISO 11452-2:2004 Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure Wa ☒ Mo ☒ Ko ☒ EMV ISO 11452-3:2001 Road vehicles
ISO 11452-2: 2019- 01 Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure bis 6 GHz EMV ISO 11452-2: 2004 Road vehicles -Compon
ISO 11452-2; SAE J1113-21; ISO 11452-4 (2005); ISO 11452-4 (2011, 2020) (excluding TWC Method); SAE J113-4 Bulk Current Injection (BCI) ISO 11452-4 (excluding TWC test method); ISO 11452-4:2020 (excluding TWC test method); SAE J11
ISO 11452-2; ISO 11452-2 (2019); ISO 11452-2 (2004); ISO 11452-3; ISO 11452-3 (2016); ISO 11452-3 (2001) Bulk Current Injection (BCI) ISO 11452-1; ISO 11452-1 (2015); ISO 11452-1 (2005); ISO 11452-4; ISO 11452-4 (2020); ISO 114
ISO 11452-2: 2019-01 Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy — Part 2: Absorber-lined shielded enclosure EMV ISO 11452-4: 2020-04 Road vehicles — Component te
ISO 11452-2; ISO 11452-2 (2004, 2019); FMC1278 (Rev 1-5); CS.00054 (2015, 2018); CS.00244 (2023); GMW3097 (2015-2024); ES-96200-00 (Rev 16-23) Radiated Immunity – Stripline ISO 11452-5; ISO 11452-5 (2002) Reverberation Radiated I
ISO 11452-2 (up to 6 GHz) Electrical Transients SAE J1113-11; ISO 7637-2; ISO 16750-2 (Sections 4.4, 4.6.3 & 4.6.4) Harley Davidson Component EMC Engineering Guideline EG-812-22614 United Nations UNECE Emissions E/
ISO 11452-2 Frequency range 200 MHz – 6 GHz; ECE Regulation 10 Annex 9 Frequency Range: 20-6000MHz Level: up to 30V/m Vertical Only: 20-400MHz Vertical & Horizontal: 400-6000MHz Radiated Immunity – Portable Transmitters ISO 11452-9
ISO 11452-2:2004, ISO 11452-2:2019 _ ISO 7637-3:2007, ISO 7637-3:2016 _ Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular, Veicoli/Vehicles Denominazione della prova
ISO 11452-2; RTCA/DO-160 C-G (Section 20); IEC 61000-4-3; EN 61000-4-3; EN 61000-4-3 (2006) +A1(2008) +A2(2010); KS C 9610-4-3; SANS 61000-4-3 Ed. 3.1 (2008) Electrical Fast/Transient Burst (EFT) EN/IEC 61000-4-4; KS C 9610-4-4;
ISO 11452-2 Immunity to Conducted Disturbances in the Extended Audio Frequency Range ISO 11452-10 Bulk Current Injection RF Immunity ISO 11452-4 Immunity to Magnetic Field ISO 11452-8
ISO 11452-2 Susceptibility (Conducted)1 ISO 13766‐1; ISO 13766‐2; ISO 14982; ISO 11451-4; ISO 11452-4 Susceptibility (Conducted Transient) ISO 13766‐1; ISO 13766‐2; ISO 14982; ISO 16750-2:2012 Sections 4.6.3 and 4.6.4; ISO 7637-2;
ISO 11452-2 Transient Immunity ISO 7637-2; ISO 7637-3
ISO 11452-2 (2004, 2019); ISO 11452-2 (limitation of 200 MHz to 6 GHz); GMW3097 (2012, 2015, 2019, 2022, 2024), Section 3.4.2; GMW3097 Section 3.4.2 Magnetic Immunity ISO 11452-8 (2015); ISO 11452-8; GMW3097 (2015, 2019, 2022, 2024),
ISO 11452-2 Second Edition 2004-11-01 Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy — Part 2: Absorber-lined shielded enclosure Frequency range 80MHz - 6GHz EMV I
ISO 11452-2 (up to 600 V/m radar pulse, up to 6 GHz) Magnetic Field Immunity ISO 11452-8 Bulk Current Injection (BCI) ISO 11452-4 Electrostatic Discharge (ESD) ISO 10605 Electrical Transient Conduction Along Supply Lines Only /
ISO 11452-2 Conducted Immunity (BCI only) ISO 11452-4 Radiated Immunity to Magnetic Fields ISO 11452-8 Radiated Immunity (Portable Transmitter) ISO 11452-9 Transient Immunity ISO 7637-2; ISO 7637-3 Electrostatic
ISO 11452-2 (2004), (2019) Portable Transmitters (360 MHz to 2.7 GHz) ISO 11452-9 (2012); ISO 11452-9 (2021) (142 MHz to 5.85 GHz) RI Reverberation Method – Mode Tuned IEC 61000-4-21; ISO 11452-11 Magnetic Field Emissions Defen
ISO 11452-2 2019-01 Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure Frequenzbereich: 80 MHz – 6000 MHz. Ohne HV (Kapitel
Bereich Norm/ Prüfverfahren/Version Titel des Standards oder Prüfverfahrens Prüfbereich/ Einschränkung 1 Standort: Erwitter Straße 105, 59557 Lippstadt 1.1 Elektromagnetische Verträglichkeit (EMV) EMV CISPR 25 Edition 3.0 :2009-03
ISO 11452-2 Bulk Current Injection (BCI) Harness excitation methods ISO 11452-4 Immunity to Magnetic Fields ISO 11452-8 Portable Transmitters ISO 11452-9 Electrostatic Discharge (ESD) ISO 10605 Conducted Transient Immunity ISO 7637-2
ISO 11452-2 Transverse electromagnetic (TEM) cell (Up to 250 V/m) ISO 11452-3 Bulk Current Injection (BCI) (Up to 300 mA) ISO 11452-4; SAE J1113-4 Stripline (Up to 250 V/m) ISO 11452-5 Magnetic Field Immunity (Up to Sever
ISO 11452-2 Conducted Transient Emissions ISO/IEC 7637-1 and -2 Conducted Immunity on Power Lines ISO 7637-2 Conducted Immunity on Signal Lines ISO 7637-3 Electrical Load ISO 16750-2:2012; ISO 16750-2:2023 (except Section 4
ISO 11452-2; CS-11979; CS00054; CS00244; FMC1278; MES_PW67602C; MES_PW67602D; ES 96200-00; GMW 3097; TSC 7006G; TSC 7006G-4; TSC 7025G; TSC 7025G-2; TSC0501G; 9.90110.01; 9.90111.01; 7796Z-FC0T-P000; 7Z0449; TB1901; 28401NDS02
ISO 11452-2:2004, ISO 11452-2:2019 _ Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular, Veicoli/Vehicles Denominazione della prova / Campi di prova Metodo di prova T
Test Technology: Test Method(s) 1: RF Radiated Emissions (cont.) MBN 50284-2; Hyundai/Kia ES 96200-00; PSA B21 7110; Renault 36-00-808; Nissan 28401NDS02; RNDS-C-00517; GMW 3097; STLA CS.00244; TSC7026G
ISO 11452-2 (2004-11) Road vehicles – Component test methods for electrical disturbances from narrowband radiated electromagnetic energy; Part 2: Absorber-lined shielded enclosure Without chapter 8.1 > 6 GHz EMV ISO 11452-2 (2019-0
ISO 11452-2 (2019); CS.00244 (2023) (Section 5.3.3); Ford FMC1278 (Rev. 5, 4; 2024) (Section RI114); GMW3097 (2022, 2024) (Section 3.4.2); HD EG-812-22614 (Rev.1 2008) (Section 404); MES PW 67602 (A, B, C) (Section RI114); TSC0501G (
Norm / Verfahren Ausgabe Titel der Norm oder des Verfahrens Prüfbereich / Einschränkung ISO 11451 -2 2015-06 Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical field Standard / in-house procedure / version Title of standard or in-house procedure Restriction 1 Basic
Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Urządzenia elektryczne i elektrycznego wyposażenia pojazdów Odporność na zaburzenia promieniowane (odporność na zaburzenia elektromagnetyczne) Za
ISO 11452-2 (Substitution Method, with and without Metallic Surface) (10kHz to 200 MHz, 150 V/m, 100 MHz to 3 GHz, 200 V/m); SAE J1113-21; FMC1278; TL81000; GMW 3097; PSA B21 7110; NISSAN 28401NDS02; BMW-GS95002; RENAULT 36-00
ISO 11452-2 Electrostatic Discharge ISO 10605 Conducted Emissions IEC CISPR 25, Section 6.3 and 6.4 Conducted Transient Emissions ISO 7637-2 Magnetic Field Immunity ISO 11452-8 Near-Field Portable Transmitters
ISO 11452-2 Radiated Immunity – Portable Transmitters ISO 11452-9 Magnetic Field Immunity EN 61000-4-8 (Helmholtz coil method only); ISO 11452-8 Transient Emissions ISO 7637-2 Conducted and Transient Immunity ISO 7637-2; ISO 7637-
Showing labs 101–150 of 244. Use pagination below to see more.