Eurofins Electrical and Electronic Testing NA
Littleton, MA, US
IEC 62368-1; EN 62368-1
23 laboratories in United States are accredited by A2LA to perform IEC 62368-1 testing. We don't know yet whether 5 of them take outside work. From the accredited scope text: “IEC 62368-1 (2014, 2018, 2023); UL 62368-1; EN IEC 61010-2-081 (2020); CAN/CSA-C22.2 NO. 62368-1; EN 61010-2-010 (2020); BS EN IEC 61010-2-010 (2020); BS EN IEC 61010-2-081 (2020); EN IEC 61010-2-101” “IEC 62368-1:20143 IEC 62368-1:20183 UL 62368-1 Ed. 3-20193 CSA C22.2 No. 62368-1-20193” “IEC 62368-1; EN 62368-1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; IEC 62368-1:2014; EN 62368-1:2014; IEC 62368-1:2018; IEC 62368-1:2023; EN 62368-1:2024; CSA C22.2 NO. 62368-1-19; UL 62368-1:2019; EN 13” “IEC 62368-1; EN 62368-1 Measurement (excluding clauses detailed in Table #4 below) 3 EN/IEC/CSA/UL 61010-1 (Electrical Equipment for Measurement, Control, and Laboratory use); IEC/EN/UL/CSA 61010-2-01”
Littleton, MA, US
IEC 62368-1; EN 62368-1
Lincoln, NE, US
IEC 62368-1; AS/NZS 62368-1
Pleasanton, CA, US
IEC 62368-1; INCLUDED MEASUREMENTS: - Operating Temperatures - Permanence of Marking - Grounding Impedance - Leakage Current - Insulation Resistance - Temperature/Humidity (Environmental Conditioning) - Fault Condition Tests
Irvine, CA, US
IEC 62368-1; EN 62368-1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; IEC 62368-1:2014; EN 62368-1:2014; IEC 62368-1:2018; IEC 62368-1:2023; EN 62368-1:2024; CSA C22.2 NO. 62368-1-19; UL 62368-1:2019; EN 13611 (2015) + A1 (2016); EN 298
Alpharetta, GA, US
IEC 62368-1 Temperature Capability with Humidity (15 to 95) % RH MIL-STD-810 Method 507; IEC 60601-1-11; IEC 62368-1 Vibration Sine and Random, 3 Axis Vibration, Frequency Range (5 Hz to 12 kHz), Force P
Skaneateles Falls, NY, US
Tests: Standard(s) 1,2: Product Safety (excluding Lithium battery test, Flammable anesthetic mixtures test, Cathode ray tubes test) (continued) IEC/EN 60601-2-38 (Ed. 1 + Am 1); ISO 80601-2-56 (Ed. 1, Ed. 2 + Am 1); ISO 806
Devens, MA, US
IEC 62368-1:20183; IEC 62368-1 Ed. 4 2023-053 Medical Equipment1 IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and
Middlebury, VT, US
IEC 62368-1 Electrical Bonding EN/IEC 60204, Section 18.2; EN/IEC 61010-1, Section 6.5.1.3; IEC 62368-1 Temperature Rise EN/IEC 61010-1, Section 10.1; IEC 62368-1 Input Current EN/IEC 61010-1, Section 5.1; EN/IEC 62368-1 Dr
Allen, TX, US
(A2LA Cert No. 3212.06) 05/05/2026 Page 2 of 2 Test Technology: Test Method(s) 1,2: Miscellaneous IEC 60529 (IP X1-X8 and IP 1X-4X) 1 When the date, edition, version, etc. is not identified in the scope of accreditation, labo
Milpitas, CA, US
IEC 62368-1; IEC 62368-1; UL 62368-1; CAN/CSA C22.2 No. 62368-1; ISA 61010-1; IEC 61010-1; EN 61010-1; UL 61010-1; CAN/CSA-C22.2 No. 61010-1
San Jose, CA, US
IEC 62368-1:2017; CAN/CSA-C22.2 No. 62368-1 (2nd Edition 2014); IEC 62368‐1 Part 1, Edition 2.0: 2014‐02 Machinery EN/IEC 60204-1:2018; EN/IEC 60204-33:2011 726 Hidden Valley Rd. Royal Oaks, CA 95076 Bruce K. Smith
Irvine, CA, US
IEC 62368-1:20143 IEC 62368-1:20183 UL 62368-1 Ed. 3-20193 CSA C22.2 No. 62368-1-20193
Plymouth Township, MI, US
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INTERTEK TESTING SERVICES NA, INC. 45000 Helm Street, Suite 150 Plymouth Township, MI 48170 Authorized Representative: Devin Selberg Phone: 616-656-7401 Local Representative: James Bry
Boxborough, MA, US
IEC 62368-1; EN 62368-1 Measurement (excluding clauses detailed in Table #4 below) 3 EN/IEC/CSA/UL 61010-1 (Electrical Equipment for Measurement, Control, and Laboratory use); IEC/EN/UL/CSA 61010-2-010 (Laboratory Equipment for the H
Sunnyvale, CA, US
IEC 62368-1 (2014, 2018, 2023); UL 62368-1; EN IEC 61010-2-081 (2020); CAN/CSA-C22.2 NO. 62368-1; EN 61010-2-010 (2020); BS EN IEC 61010-2-010 (2020); BS EN IEC 61010-2-081 (2020); EN IEC 61010-2-101 (2022/A11:2022); BS EN 62368-1 (201
Alachua, FL, US
Test Technology: Test Method(s) 1: Israel SI 961 Part 11; SI 961 Part 14.1; SI 961 Part 14.2; SI 961 Part 15; SI 961 Part 24; SI 961 Part 32, SI 961 Part 35; SI 961 part 48.1; SI 961 Part 48.7; SI 961Part 48.24; SI 961 Part 48.3; S
Sterling, VA, US
IEC 62368-1; IEC 62368-1:2014 Ed. 2; IEC 62368-1:2014 (Ed. 2.0) + COR1:2015 + COR2:2015 IEC 62368-1:2023; EN 62368-1; EN 62368-1:2014 (2nd Ed.); EN 62368-1:2014 + AC:2015 + AC:2017-03 + A11:2017; EN IEC 62368-1:2024 + A11:2024; IEC 623
San Diego, CA, US
IEC 62368-1 (1Ed 2010; 2Ed 2014; 3Ed 2018; 4Ed 2023); EN 62368-1 (2Ed 2014 + A11:2017); EN IEC 62368-1:2020; UL 62368-1 (1Ed 2012, 2Ed 2014, 3Ed 2019 +R:2021); CSA C22.2 No. 62368-1 (2012, 2014, 2019 +R:2021); UL 4200A (2015+R:2023)
Roseville, CA, US
IEC 62368-1; UL/CSA 62368-1 5.2 Classification of Electrical Energy Sources 5.4.1.4; 6.3.2; 9.0; B.2.6 Temperature Measurements 5.4.2.2; 5.4.2.4; 5.4.3 Minimum Clearances/Creepage Distances 5.4.2.3 Minimum Clearances Distances Using
Austin, TX, US
IEC 62368-1; UL 62368-1; EN 62368-1; CAN/CSA-C22.2 No. 62368-1
Boise, ID, US
IEC 62368-1, section 5.4.9 Touch Current IEC 60950-1, section 5.1; SNI IEC 60950-1:2016, section 5.1; IEC 62368-1, section 5.7 Republic of Korea Technical Regulations Notice for Conformity Assessment of Broadcasting and Communicati
San Jose, CA, US
IEC 62368-1:2014 / IEC 62368-1:2018 / EN IEC 62368- 1:2020+A11:2020 / IEC 62368-1:2023 (excluding: --Cl. 4.4.3.7, Cl. 4.4.4.6/4.4.3.6, Cl. 4.4.4.9/--, Cl. 4.7, Cl. 4.8.4, Cl. 4.8.5, Cl. 5.2.2.7, Cl. 5.4.1.5.2, Cl. 5.4.1.10.2, Cl.
Middleburg Heights, OH, US
IEC 62368-1; UL 62368-1 Safety of machinery - electrical equipment of machines - Part 1: General requirements IEC 60204-1 Arc Welding equipment – Part 1: Welding power sources IEC 60974-1 Arc Welding equipment - Part 1:
American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.